Aborting Loopbacks - Paradyne 3166 User Manual

Zhone acculink 3166 dsu-csu combo: users guide
Hide thumbs Also See for 3166:
Table of Contents

Advertisement

Aborting Loopbacks

"
3166-A2-GB20-20
The Abort Loopback command stops all loopback tests or any selected loopback
test currently active on the DSU/CSU.
Procedure
To abort one or more loopback tests:
1. From the top-level menu screen, select Test.
2. From the Test screen, select Lpbk.
Test:
Rlpbk Lpbk
F1
3. From the Loopback screen, select Abort.
Loopback:
Abort
LLB
F1
4. From the Loopback Abort screen, press the desired Function key to abort All
or one specific loopback test. Use the scroll keys, if necessary.
Loopback: Abort
All
LLB
F1
When abort is complete, the message Command Complete appears on the
Abort screen.
NOTE:
If you mistakenly choose to abort a loopback test that is not currently running,
a Command Complete message will still display and the loopback that is
currently active will still be running. Use the TStat branch to view the test
status to determine if the abort was successful.