Configuration Options
Port Configuration Options
C-2
Table C-1. Port Configuration Options (1 of 5)
Port Type: E530 (Factory 1)
Next
E530
V.35
RS449
Data Port Type. Allows selection of the data port interface type.
E530 – Configures the port as an EIA-530-A compatible interface. EIA-530-A DTEs can
be directly connected to the Port1 connector.
V.35 – Configures the port as a V.35 compatible interface. V.35 DTEs can be connected
to the Port1 connector using an EIA-530-A-to-V.35 adapter cable.
RS449 – Configures the port as an RS449 compatible interface. RS449 DTEs can be
connected to the Port1 connector using an EIA-530-A-to-RS449 adapter cable.
X.21 – Configures the port as an X.21 compatible interface. X.21 DTEs can be
connected to the Port1 connector using an EIA-530-A-to-X.21 adapter cable.
NOTE:
If this configuration option is set to X.21, set the All Ones configuration
option to RTS or Disab.
Base Rate: Nx64
Next
Nx64
Nx56
Prev
Data Port Base Rate. Allows selection of the base rate for the data port. The data rate
for the port is a multiple (from 1 to 24) of the base rate specified with this configuration
option.
Nx64 – Sets the base rate for this port to 64 kbps. The data rate is N x64 kbps, where N
is a number from 1 to 24.
Nx56 – Sets the base rate for this port to 56 kbps. The data rate is N x56 kbps, where N
is a number from 1 to 24.
Net DCLB: Disab (Factory 1)
Next
Disab
V.54
FT1
Network Initiated DCLB. Allows the initiation and termination of a Data Channel
Loopback (V.54 loop 2) by the receipt of a V.54 DCLB-actuate sequence or
DCLB-release sequence from the network or far-end device. The sequences may be
either V.54 or FT1 (ANSI) compliant sequences.
Disab – Ignores the DCLB-actuate and DCLB-release sequences for this port.
V.54 – Enables DCLB-actuate and DCLB-release sequences that comply with the V.54
standard for ''Inter-DCE signaling for point to point circuits."
FT1 – Enables DCLB-actuate and DCLB-release sequences that comply with the ANSI
T1.403, Annex B standard for ''In-band signaling for fractional-T1 (FT1) channel
loopbacks."
Both – Enables DCLB-actuate and DCLB-release sequences that comply with either
the ANSI or V.54 standard. The type of actuate and release sequences do not have to
match.
March 1999
V.35 (Factory 2)
X.21
Prev
Both (Factory 2)
Both
Prev