Num Trap Mgrs: 1
Next
1
2
3
4
5
Number of Trap Managers. Specifies the number of SNMP trap managers that are to
receive traps for this unit.
NOTE:
You must configure an IP address for each trap manager that is to receive
trap messages.
Trap n IP Adr:
Next
Edit
Clear
Prev
Trap n IP Address. Specifies the IP address for each trap manager. This configuration
option is repeated for all trap managers supported by the unit.
Edit – Allows you to edit or display the IP address for Trap Manager n .
Clear – Allows you to clear the IP address for Trap Manager n . The IP address is set to
000.000.000.000.
Trap n Dst: None
Next
None
Com
FDL
Trap Manager n Destination. Specifies the network destination for Trap Manager n . This
configuration option is displayed for the number of trap managers ( n ) specified by the
Number of Trap Managers configuration option.
None – No Trap Manager n network destination. Traps are discarded.
Com – The Trap Manager n network destination is the communication port. This
selection only appears if the Com Use configuration option is set to Mgmt.
FDL – The Trap Manager n network destination is the FDL management link. This
selection only appears if the FDL management link is enabled.
EDL1 – The Trap Manager n network destination is the EDL1 port. This selection only
appears if the synchronous data port's EDL management link is enabled.
NOTE:
If the chosen destination link is disabled or down, the traps are discarded.
Return to this menu and choose another destination.
Gen Trap: Both
Next
Disab
Warm
General Trap Types. Specifies the general trap types to enable.
Disab – Disables the sending of trap messages for warmStart and authenticationFailure
events.
Warm – Sends trap messages for warmStart events to the currently configured trap
manager(s).
Auth – Sends trap messages for authenticationFailure events to the currently configured
trap manager(s).
Both – Sends trap messages for warmStart and authenticationFailure events to the
currently configured trap manager(s).
NOTE:
This configuration option is not available if the
option (in the Alarm Configuration Options section on page C-16) is
disabled.
March 1999
6
Prev
EDL1
Prev
Auth
Both
Prev
Configuration Options
SNMP Trap
configuration
C-23