Monitoring and Testing
4-8
Table 4-3. Performance Registers (2 of 3)
Register
Interval Description
SES
The number of severely errored
seconds for the current interval. A
severely errored second is any
second with 320 or more CRC
errors, or any second with one or
more OOF events. The maximum
is 900 seconds.
BES
The number of bursty errored
seconds for the current interval. A
bursty errored second is any
second with more than one, but
less than 320, CRC errors. The
maximum is 900 seconds.
LOFC
The loss of frame count for the
current interval. This is a count of
the number of times that an LOF is
declared. The maximum count is
255.
CSS
The number of controlled slip
(Not valid
seconds for the current interval.
for Port
registers.)
March 1999
Totals Description
The total number of severely
errored seconds for the previous
x hours, where x is 24 hours for
aggregate performance and
8 hours for port performance.
The total number of bursty errored
seconds for the previous x hours,
where x is 24 hours for aggregate
performance and 8 hours for port
performance.
The total loss of frame count for the
previous x hours, where x is
24 hours for aggregate
performance and 8 hours for port
performance.
The total number of controlled slip
seconds for the previous x hours,
where x is 24 hours for aggregate
performance and 8 hours for port
performance.