Peripheral Configuration - Siemens SIMATIC IPC BX-56A Operating Instructions Manual

Table of Contents

Advertisement

Configuring firmware
3.4 "Advanced" tab
3.4.9

"Peripheral Configuration"

Calling "Peripheral Configuration"
Select: "Setup Utility (Page 10)" > "Advanced" > "Peripheral Configuration".
Firmware setting
COM Port 1(X31)
Base I/O Address
3F8h/2F8h/3E8h/
2E8h/338h/228h/
220h/238h
Interrupt
IRQ3/IRQ4/IRQ5/I
RQ6/IRQ7/IRQ10/I
Peripheral Type
RS485/RS422 Full
RS485 Half
Autodirection
COM Port 2(X32)
Base I/O Address
3F8h/2F8h/3E8h/
2E8h/338h/228h/
220h/238h
Interrupt
IRQ3/IRQ4/IRQ5/I
RQ6/IRQ7/IRQ10/I
Peripheral Type
RS485/RS422 Full
RS485 Half
Autodirection
16
Value
Setting in delivery state
BX-56A
Enabled
x
Disabled
3F8h
IRQ4
RQ11
Loopback
RS232
x
Duplex
Duplex
Manual
Automatic
x
Enabled
x
Disabled
2F8h
IRQ3
RQ11
Loopback
RS232
x
Duplex
Duplex
Manual
Automatic
x
BX-59A
x
Enable the serial port. You can then set the
I/O base address and the interrupt.
Disable the serial port. This releases the used
resources.
3F8h
The I/O base address is pre-assigned and
recommended.
IRQ4
The interrupt is pre-assigned and
recommended.
Mode for testing the hardware.
x
Non-isolated connection for short distances in
interference-free environment.
Isolated connection for environment with
EMC load, transmitting and receiving at the
same time.
Isolated connection for environment with
EMC load.
This option is only available when "Peripheral
Type" is configured as "RS485 Half Duplex" or
x
"RS485/RS422 Full Duplex".
x
Enable the serial port. You can then set the
I/O base address and the interrupt.
Disable the serial port. This releases the used
resources.
2F8h
The I/O base address is pre-assigned and
recommended.
IRQ3
The interrupt is pre-assigned and
recommended.
Mode for testing the hardware.
x
Non-isolated connection for short distances in
interference-free environment.
Isolated connection for environment with
EMC load, transmitting and receiving at the
same time.
Isolated connection for environment with
EMC load.
This option is only available when "Peripheral
Type" is configured as "RS485 Half Duplex" or
x
"RS485/RS422 Full Duplex".
Firmware/BIOS description (SIMATIC IPC BX-56A, IPC BX-59A)
Operating Instructions, 10/2023, A5E52427534-AA
Meaning