Firmware setting
COM Port 3(X33)
Base I/O Address
3F8h/2F8h/3E8h/
2E8h/338h/228h/
220h/238h
Interrupt
IRQ3/IRQ4/IRQ5/I
RQ6/IRQ7/IRQ10/I
Peripheral Type
RS485/RS422 Full
Autodirection
COM Port 4(X34)
Base I/O Address
3F8h/2F8h/3E8h/
2E8h/338h/228h/
220h/238h
Interrupt
IRQ3/IRQ4/IRQ5/I
RQ6/IRQ7/IRQ10/I
Peripheral Type
RS485/RS422 Full
Autodirection
Onboard Ethernet
1 (LAN 1, X1 P1)
Onboard Ethernet
[Mac Address]
1 Address
Onboard Ethernet
2 (LAN 2, X2 P1)
Firmware/BIOS description (SIMATIC IPC BX-56A, IPC BX-59A)
Operating Instructions, 10/2023, A5E52427534-AA
Value
Setting in delivery state
Enabled
x
Disabled
3E8h
IRQ5
RQ11
Loopback
RS232
x
Duplex
RS485 Half
Duplex
Manual
Automatic
x
Enabled
x
Disabled
2E8h
IRQ6
RQ11
Loopback
RS232
x
Duplex
RS485 Half
Duplex
Manual
Automatic
x
Enabled
x
Disabled
Enabled
x
Disabled
x
Enable the serial port. You can then set the
I/O base address and the interrupt.
Disable the serial port. This releases the used
resources.
3E8h
The I/O base address is pre-assigned and
recommended.
IRQ5
The interrupt is pre-assigned and
recommended.
Mode for testing the hardware.
x
Non-isolated connection for short distances in
interference-free environment.
Isolated connection for environment with
EMC load, transmitting and receiving at the
same time.
Isolated connection for environment with
EMC load.
This option is only available when "Peripheral
Type" is configured as "RS485 Half Duplex" or
x
"RS485/RS422 Full Duplex".
x
Enable the serial port. You can then set the
I/O base address and the interrupt.
Disable the serial port. This releases the used
resources.
2E8h
The I/O base address is pre-assigned and
recommended.
IRQ6
The interrupt is pre-assigned and
recommended.
Mode for testing the hardware.
x
Non-isolated connection for short distances in
interference-free environment.
Isolated connection for environment with
EMC load, transmitting and receiving at the
same time.
Isolated connection for environment with
EMC load.
This option is only available when "Peripheral
Type" is configured as "RS485 Half Duplex" or
x
"RS485/RS422 Full Duplex".
x
The onboard Ethernet interface "X1 P1" is
enabled.
The onboard Ethernet interface "X1 P1" is
disabled.
The Onboard Ethernet 1 address is defined by
this value.
x
The onboard Ethernet interface "X2 P1" is
enabled.
The onboard Ethernet interface "X2 P1" is
disabled.
Configuring firmware
3.4 "Advanced" tab
Meaning
17