Configuring firmware
3.4 "Advanced" tab
Firmware
Value
setting
PCIe Express
Enabled
Port Enable
Disabled
PCIe Max Link
Speed
Detect Timeout
[Number]
PCI Express Slot (X303)
NOTICE: PEC Express Slot (X303) is unavailable for IPC BX-56A.
PCIE (BUS:xx
Present/Not
Device:xx
Presented
Function:xx)
PCIe Express
Enabled
Port Enable
Disabled
PCIe Max Link
Speed
Detect Timeout
[Number]
PCI Express Slot (X304)
NOTICE: PEC Express Slot (X304) is unavailable for IPC BX-56A.
PCIE (BUS:xx
Present/Not
Device:xx
Presented
Function:xx)
PCIe Express
Enabled
Port Enable
Disabled
PCIe Express
Port Enable
Detect Timeout
[Number]
Serial ATA Port
[Empty]/[Drive
(X54)
name]
Software
SUPPORTED/Unk
Preserve
22
Setting in
delivery state
x
Auto
Gen1
Gen2
Gen3
x
Gen4
0
Auto
Gen1
Gen2
Gen3
Gen4
Auto
Gen1
Gen2
Gen3
Gen4
nown
x
Control the PCI Express Root Port.
x
Configure PCIe Speed.
NOTICE:
The PCIe max link speed configuration options might be different
according to different Extension Module you are using. The
display menu is subject to the actual using case.
0
The number of milliseconds reference code will wait for link to
exit. Detect state for enabled ports before assuming there is no
device and potentially disabling the port.
The input range is from 0 to 65535.
The PCIE bus device function is present or not.
x
Control the PCI Express Root Port.
x
Configure PCIe Speed.
NOTICE:
The PCIe max link speed configuration options might be different
according to different Extension Module you are using. The
display menu is subject to the actual using case.
0
The number of milliseconds reference code will wait for link to
exit. Detect state for enabled ports before assuming there is no
device and potentially disabling the port.
The input range is from 0 to 65535.
The PCIE bus device function is present or not.
x
Control the PCI Express Root Port.
Configure PCIe Speed.
NOTICE:
The PCIe max link speed configuration options might be different
according to different Extension Module you are using. The
x
display menu is subject to the actual using case.
0
The number of milliseconds reference code will wait for link to
exit. Detect state for enabled ports before assuming there is no
device and potentially disabling the port.
The input range is from 0 to 65535.
Firmware/BIOS description (SIMATIC IPC BX-56A, IPC BX-59A)
Meaning
Operating Instructions, 10/2023, A5E52427534-AA