I039
Historical alarm 1 (oldest)
I040
Historical alarm 2
I041
Historical alarm 3
I042
Historical alarm 4
I043
Historical alarm 5 (most recent)
I044
Exchange service
I045
Next antilegio
I046
Fw comfort development review Not available
I047
Fw safety review
I048
Fw safety development review
I049
Fan Fw review

7 CONTROL PANEL

A A
B B
1
1
Normally used to increase the domestic hot water
A
temperature value, when the arrow is highlighted
it carries out a confirmation function
Normally used to decrease the DHW temperature
B
value, but when the arrow
a back/annul button
C+D
Heating time programming, status change
Normally used to increase the heating water temper-
C
ature value, when highlighted the arrow
you to move within the menu P1
Normally used to decrease the heating water tem-
D
perature value, when highlighted the arrow allows
you to move within the menu P1
Access to the clock setting menu (see section "8 IN-
A+C
STRUCTIONS FOR USE" )
B+D
Time band programming
Used to modify the boiler operating status (OFF,
1
SUMMER and WINTER)
Used to reset the alarm status, or to interrupt the
2
venting cycle
Used to access menus INFO (press lightly) and P1
(press > 2 sec). When the
3
the display, this button has an ENTER function and
is used to confirm the value set while programming
a technical parameter
1+3
Button lock and release
Used when the boiler is OFF, to activate the flue gas
2+3
analysis function (CO)
List of the last 5 alarms recorded
Number of days that have elapsed since the CFS signal was activated (P707 = 0)
Days missing until the next anti-legionella (when P501=1 or 2)
Not available
Not available
Not available
2 2
3 3
is highlighted it acts as
allows
Enter
icon appears on
Indicates connection to a remote device (OTBus or
RS485)
C C
Indicates connection to a WIFI device
D D
Indicates the presence of an outdoor temperature sen-
sor
Indicates the activation of special DHW functions
Lights up if an alarm is triggered
Lights up in the event of a fault together with the icon
excluding flame and water alarms
Indicates presence of a flame, in the event of a flame
lockout the icon appears
Flashes with temporary water alarms, steady with
definitive alarms
Lights up in the presence of alarms requiring manual re-
Reset
lease by the operator
Enter
Lights up when confirmation is required
When this icon is active, the "confirm" function of button
A is active
When this icon is active, the "back/annul" function of but-
ton B is active
When this icon is active, the user can navigate the menu
or increase the value of the selected parameter
When this icon is active, the user can navigate the menu
or decrease the value of the selected parameter
Lights up if heating mode is active; flashes with a heat-
ing request in progress
Lights up if DHW mode is active; flashes with a DHW
request in progress
Indicate the set point level (1 notch minimum value, 4
notches maximum value)
Indicate the days of the week
1 2 3 4 5 6 7
AUTO
Time band programming
ON
MAN ON
Manual time programming ON
MAN OFF
Manual time programming OFF