Disassembly; Incorrect Disassembly - Siemens SITRANS TDL Operating Instructions Manual

In situ laser gas analyzers
Hide thumbs Also See for SITRANS TDL:
Table of Contents

Advertisement

5. Tighten the connec‐
6. Mount the emitter unit. Follow the same procedure as for the receiver.
7. The system is now prepared for electrical connection.
5.4

Disassembly

Note
Correct disassembly
For correct disassembly, complete the installing and mounting steps in reverse order.
5.4.1

Incorrect disassembly

Incorrect disassembly
The following risks may result from incorrect disassembly:
- Injury through electric shock
- Risk through emerging media when connected to the process
In order to disassemble correctly, observe the following:
• Before starting work, make sure that you have switched off all physical variables such as
• If the device contains hazardous media, it must be emptied prior to disassembly. Make sure
• Secure the remaining connections so that no damage can result if the process is started
SITRANS TDL
Operating Instructions, 05/2023, A5E51429088_AA
tion using the clamp
screw.
Connection with the clamp screw
WARNING
pressure, temperature, electricity etc. or that they have a harmless value.
that no environmentally hazardous media are released.
unintentionally.
Installing/mounting
5.4 Disassembly
47

Advertisement

Table of Contents
loading

Table of Contents