2-Post Rack Mount Installation
You can position the mid-bracket on to the rail in the following configurations:
3 inches in from the rack mount rail ear for securing to the rear rack post flange in a 3 inch rack
post flush mount configuration. See
7.25 inches in from the rack mount rail ear for securing to the rear rack post flange in a 7.25
inch rack post flush mount configuration. See
7.25 inches in from the rack mount rail ear for securing to the front rack post flange for a mid-
mount configuration (the rear rack post flange is not used in a mid-mount configuration). See
Figure
The 2-post rack mount rail can be installed in both a flush mount or mid-mount configuration. In a
flush mount configuration, the rack mount rail is secured to both the front and rear flange of either
a 3 inch or 7.25 inch rack post.
Mid-Bracket to Rail 3 Inch Flush Mount Assembly
To secure the mid-bracket to the rail for a 3 inch post flush mount assembly:
1.
Align the mid-bracket (callout 2) with the four rail holes closest to the rail ear (callout 3) as
shown in
2.
Insert and secure the four screws (callout 1) from the rack mount extension assembly for both
rails.
Figure C-8
1
Four screws from extension rack assembly
2
Mid-bracket
C-10 Optional Rack Mount Rail Kit Installation
C-10.
Note: If you are installing the rack mount rail in a flush mount 7.25 inch rack post or a mid-mount
configuration, proceed to
"Mid-Bracket to Rail 7.25 Inch Flush Mount or Mid-Mount
page C-11, otherwise continue here.
Figure C-8
for both rails.

Securing Mid-Bracket to Rail 3 Inch Flush Mount

Figure
C-8.
Figure
C-9.
3
Rail ear
Assembly" on