GR SERIES GAS FRYERS - REMOVAL AND REPLACEMENT OF PARTS
6.
Reverse procedure to install and check for
proper operation.

PILOT BURNER

WARNING: DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT /
TAGOUT PROCEDURES.
WARNING: SHUT OFF THE GAS BEFORE
SERVICING THE UNIT.
WARNING: ALL GAS JOINTS DISTURBED
DURING SERVICING MUST BE CHECKED FOR
LEAKS. CHECK WITH A SOAP AND WATER
SOLUTION (BUBBLES). DO NOT USE AN OPEN
FLAME.
1.
Remove burners (as necessary) as outlined
under MAIN BURNERS.
2.
Disconnect thermopile lead wires from N.O. and
COM terminals on the high limit thermostat.
3.
Disconnect pilot tube from pilot burner.
NOTE: With pilot tube disconnected from pilot
burner, the pilot orifice is accessible for inspection or
cleaning.
CAUTION: If orifice is clogged with debris, clean
with air or liquid only.
4.
Remove pilot burner from pilot mounting
bracket stool (on fry tank).
5.
Remove pilot burner from pilot mounting
bracket.
6.
Reverse procedure to install and check for
proper operation.
WARNING: SHUT OFF THE GAS BEFORE
SERVICING THE UNIT.
WARNING: ALL GAS JOINTS DISTURBED
DURING SERVICING MUST BE CHECKED FOR
LEAKS. CHECK WITH A SOAP AND WATER
SOLUTION (BUBBLES). DO NOT USE AN OPEN
FLAME.
1.
Remove pilot burner as outlined under PILOT
BURNER.
2.
Remove mounting nut securing thermopile to
pilot burner.
Page 9 of 24

THERMOPILE

WARNING: DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT /
TAGOUT PROCEDURES.