GR SERIES GAS FRYERS - REMOVAL AND REPLACEMENT OF PARTS
SPECIFICATIONS
Electrical
•
120VAC supply for Filter-Ready fryers and
Kleenscreen filter models only. The filter pump
motor draws approximately 5 amps.
Gas Pressures
Manifold (per fryer section):
•
Natural - 4" W.C.
•
Propane - 10" W.C.
Building supply pressure (Min):
•
Natural - 5" W.C. (7" W.C. battery units)
•
Propane - 11" W.C. (12" W.C. battery units)
NOTE: Propane or Natural gases -14" W.C. (Max).
REMOVAL AND REPLACEMENT OF PARTS
FRONT PANEL
WARNING: DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT /
TAGOUT PROCEDURES.
1.
Open fryer door and remove screws from front
panel.
2.
Lift front panel from fryer.
3.
Reverse procedure to install.
Input BTU Rating
GR SERIES
GR25, GR25F
GR35, GR35F
GR45, GR45F
GR65, GR65F
GR85, GR85F
Standard
•
Standard set of hand tools.
•
VOM with AC current tester.
NOTE: Any quality VOM with a sensitivity of
20,000 ohms per volt can be used.
•
Temperature tester (thermocouple type).
•
U-Tube Manometer.
•
Pipe joint compound suitable for use with
propane gas.
1.
Open the fryer door and remove screws
securing hinge & door assembly to fryer.
Page 5 of 24
NO. OF
BTU/HR/SECTION
TUBES
2
60,000
3
90,000
4
120,000
5
150,000
5
150,000
TOOLS
DOOR
F25125 (March 2003)