FRYMATE (DUMP STATION)
WITH OPTIONAL HEATER
SYMPTOM
No heat.
KLEENSCREEN FILTERING
SYSTEM
SYMPTOM
Oil not filtering, pump motor is on.
Shortening not discarding, pump motor
on.
Pump motor is not running.
GR SERIES GAS FRYERS - TROUBLESHOOTING
1.
2.
3.
4.
1.
Filter screen plugged.
2.
Clog in filter system lines.
NOTE: When all filtered oil is returned to the fry tank and filter
power switch is off, open the filter drawer approximately 1".
Allow the remaining shortening in the line to drain into the filter
tank to prevent possible clogging after the shortening cools and
solidifies. Close the filter drawer when complete.
Shortening below 300 / F (too thick).
3.
4.
Filter valve switch malfunction.
5.
Filter valve mechanical malfunction.
6.
Pump is inoperative.
1.
Filter screen plugged.
2.
Clog in filter system lines.
NOTE: When all filtered oil is returned to the fry tank and filter
power switch is off, open the filter drawer approximately 1".
Allow the remaining shortening in the line to drain into the filter
tank to prevent possible clogging after the shortening cools and
solidifies. Close the filter drawer when complete.
Shortening below 300 / F (too thick).
3.
4.
Discard valve switch malfunction.
5.
Discard valve mechanical malfunction.
6.
Discard hose connection not fully engaged.
7.
Pump is inoperative.
1.
Filter power switch inoperative.
2.
Filter/discard handle not extended.
3.
Filter/discard valve switch malfunction.
4.
Filter relay malfunction.
5.
Pump motor inoperative.
Page 23 of 24
POSSIBLE CAUSES
Unplugged.
Power switch off or inoperative.
Main circuit breaker off or open.
Malfunctioning heat assembly.
POSSIBLE CAUSES
F25125 (March 2003)