Gas Pilot - Vulcan-Hart 1GR45A Service Manual

Gra series gas fryers with kleenscreen plus filtration sytems
Table of Contents

Advertisement

GRA SERIES GAS FRYERS - REMOVAL AND REPLACEMENT OF PARTS
3.
Disconnect pilot tube from gas combination
valve.
4.
Disconnect gas line fittings then remove gas
combination valve.
A.
Remove gas line fittings from gas
combination valve and install (in same
orientation) on the replacement valve.
5.
Reverse procedure to install and check for
proper operation.
A.
Clean the pipe threads and apply pipe joint
compound to threads. Any pipe joint
compound used must be resistant to the
action of propane gases.

GAS PILOT

1.
Remove GAS BURNERS as necessary.
2.
Remove pilot burner assembly and bracket from
pilot bracket stand-off on the fry tank.
3.
Remove wire tie and disconnect ignitor cable
from ignitor/flame sense electrode on the gas
pilot.
F25377 (March 2010)
4.
Disconnect pilot tube from gas pilot.
5.
Remove screws (2) securing gas pilot to
mounting bracket.
A.
To remove gas orifice from pilot for
inspection or cleaning, disconnect the gas
orifice fitting from pilot body.
B.
If orifice is clogged with debris, clean with
air or liquid only.
GAS PILOT FOR ELECTRONIC IGNITION SHOWN
6.
Reverse procedure to install and check for
proper operation.
A.
Secure ignitor to pilot tube with wire tie.
Page 8 of 36