In standby mode (but not in energy saver mode):
The adjustment is done once, depending on:
The machine checks the above conditions in
standby mode every 10 minutes (SP 3512 002).
Then, line position adjustment is done if two of the
conditions occurs.
New PCDU
When the machine detects a new PCDU, line
position adjustment is automatically done twice.
Slide 131
No additional notes
Adjustment Conditions (5)
» Time since the previous line position adjustment
» Temperature change since the previous line position
adjustment
» Number of prints since the previous line position
adjustment
» Time and number of prints, or temperature and number
of prints