Using Finsgateway - Omron SYSMAC CS Series Operation Manual

Hide thumbs Also See for SYSMAC CS Series:
Table of Contents

Advertisement

Connecting to the PLC

1-6-3 Using FinsGateway

Communications network
Serial
Host Link Network
co
communications
u ca o s
(See note 1.)
Peripheral bus
(See note 2.)
Controller Link Network
Ethernet Network
Connecting via Serial Communications
Host Link (SYSMAC
WAY)
Peripheral Bus
Connections to the Peripheral
Port of the CPU Unit
CX-Process
Tool
IBM PC/AT or
compatible
(9-pin male)
CS1W-CN226 or
CS1W-CN626
Connecting Cable
Connecting through a Controller Link Support Board
30
The following three methods can be used to connect to the PLC. Regardless of
the connection method, use FinsGateway Version 2 or higher (embedded) as
the communications driver.
FinsGateway
communications driver
Serial Unit Driver
CLK (PCI slot) Driver
(Not supported by
FinsGateway Version 2)
Controller Link Driver
ETN_UNIT Driver
Note
1. Host Link communications use FINS commands enclosed in a header and
terminator data (i.e., SYSWAY-CV for FinsGateway). Host Link communica-
tions (SYSMAC WAY) is set for the PLC.
2. FinsGateway Version 2003 only.
The personal computer uses the FinsGateway (Version 2 or higher) Serial Unit
Driver to connect to the PLC's peripheral or RS-232C port via Host Link commu-
nications.
The personal computer uses the FinsGateway (Version 2003) Serial Unit Driver
to connect to the PLC's peripheral or RS-232C port via the peripheral bus.
Loop Control Unit
CS1 CPU Unit
Peripheral
port
Note The FinsGateway Version 3 Serial Unit Driver must be installed to enable con-
necting the PLC via Host Link communications.
The personal computer can be connected to the PLC through a Controller Link
Network using the FinsGateway Version 3 CLK (PCI slot) Driver or the FinsGate-
way Version 2 or higher Controller Link Driver.
CX-Process Tool
(IBM PC/AT or
compatible)
Connecting to the PLC's peripheral or RS-232C
po
port via Host Link.
a os
Connecting through the Controller Link Support
Board to a PLC with a Controller Link Unit
mounted.
Connecting through the Ethernet Board to a PLC
with an Ethernet Unit mounted.
Connections to the RS-232C port of the CPU
Unit or Serial Communications Board or Unit
CX-Process
Loop Control Unit
Tool
IBM PC/AT or
compatible
(9-pin male)
XW2Z-200S-CV
Connecting Cable
Loop Control Unit
Controller
Controller
Link Unit
Link Unit
Controller Link Network
Controller Link Support Board
Section
Contents
CS1 CPU Unit
RS-232C Port
Loop Control Unit
1-6