Connecting to the PLC

1-5-5 Incompatibility with Versions Earlier than Version 3.2

Function Blocks
Incompatible with Earlier
Versions

1-5-6 Incompatibility with Versions Earlier than Version 4.0

Function Blocks
Incompatible with Earlier
Versions
1-6

Connecting to the PLC

28
The following function blocks can be used only with LCB01/LCB05 version 1.5 or
higher, or LCB03, together with the CX-Process Tool version 3.20 or higher.
Ai4 Terminal (PTS51), Ai8 Terminal (PTS55), Ai4 Terminal (PTS52), Ai8
Terminal (PTS56), Ai8 Terminal (PDC55), Ao2 Terminal (DA021),
Ai4/Ao2 Terminal (MAD42)
• If an earlier version of the Loop Control Board is used with CX-Process Tool
version 3.20 or higher, these function blocks can be registered but the data for
the function blocks won't be downloaded to the Loop Control Unit when LCU
element data is downloaded. (The supported function blocks will be down-
loaded normally.)
• If Loop Control Board version 1.20 or higher is used with an earlier version of
the CX-Process Tool, these function blocks cannot be registered in the CX-
Process Tool, so they cannot be downloaded to the Loop Control Unit.
If these function blocks have been downloaded to the Loop Control Unit al-
ready, the data for these function blocks won't be uploaded from the Loop Con-
trol Unit. The supported function blocks will be uploaded normally. (If Upload
New is selected, the unsupported function blocks will be empty.)
The following function blocks can be used only with LCB01/LCB05 version 2.0 or
higher, or LCB03, together with the CX-Process Tool version 4.0 or higher.
Ai4 Terminal (PTS51/52) (Block Model 590), Ao2 Terminal (DA021)
(Block Model 591), Ai4/Ao2 Terminal (MAD42) (Block Model 592)
• If an earlier version of LCBjj is used with an earlier version of the CX-Pro-
cess Tool, these function blocks cannot be registered in the CX-Process Tool,
so they cannot be downloaded to the LCBjj.
Either one of the following communications drivers can be selected to support
the connection with a PLC (Programmable Controller):
• FinsGateway
• CX-Server
When the CX-Process Tool starts up, a dialog box is displayed to select whether
FinsGateway or CX-Server will be used as the communications driver.
Section
1-6