Mitsubishi Electric MELSEC iQ-R C Series Programming Manual page 238

Controller module
Table of Contents

Advertisement

*1
Error code
Decimal
Hexadec
imal
-31
FFE1H
-32
FFE0H
-33
FFDFH
-34
FFDEH
-35
FFDDH
-36
FFDCH
-37
FFDBH
-42
FFD6H
-43
FFD5H
-52
FFCCH
-53
FFCBH
-54
FFCAH
-55
FFC9H
-56
FFC8H
-80
FFB0H
-81
FFAFH
-82
FFAEH
236
Description
Module load error
Loading modules required for executing functions failed.
Resource timeout error
The resource is being used by another task/thread and is not
released within 30 seconds.
Communication target unsupported error
The module specified as the communication target by a network
number and station number is not supported.
Registry open error
Opening parameter files in the registry failed.
Registry read error
Reading parameter files from the registry failed.
Registry write error
Writing parameter files to the registry failed.
Communications initialization error
Initializing the setting for communication failed.
Close error
Communications cannot be closed.
ROM operation error
A TC setting value was written to the CPU module during ROM
operation.
MELSEC data link function service error
MELSEC data link function service is disabled.
Timeout value error
The specified timeout value is out of range.
I/O number error
The specified I/O number is out of range.
Logical station number error
The specified logical station number is out of range.
Target CPU error
The specified target CPU is out of range.
Connection destination CPU error
The connection destination CPU is not an RCPU.
Label code mismatch error
Label assignment information of the CPU module was changed.
Label incorrect value error
An incorrect label name was specified.
• Non-existent label name
• Label name assigned to a device which does not support
random read/write.
• Label name assigned to a device which is specified by the
inappropriate specification method (index modification or
indirect specification)
Corrective action
• The memory may be insufficient. End another running task or
reduce the access size.
• Check the status of the system drive of the C Controller
module.
• Retry.
• The memory may be insufficient. End another running task.
• Check if the C Controller module is running normally.
• Reset the C Controller module, or turn the power OFF and
ON.
• Check if the module specified as the communication target by
a network number and station number is supported.
• Check the settings of the access target set in CW
Configurator.
Check if the access target is correctly set with CW Configurator.
• Check if the access target is correctly set with CW
Configurator.
• Check if the setting for the channel number is enabled.
• Reset the C Controller module or turn the power OFF and ON
after checking the parameters with CW Configurator again
and writing them.
• Check if the access target module supports dedicated
function libraries. (MELSEC iQ-R C Controller Module
User's Manual)
• Check if the standard ROM has already been shutdown.
• Reset the C Controller module, or turn the power OFF and
ON.
• Retry.
• The memory may be insufficient. End another running task.
• Check the available memory capacity.
• Check if the C Controller module is running normally.
• Reset the C Controller module, or turn the power OFF and
ON.
• Retry.
• Check if the C Controller module is running normally.
• Reset the C Controller module, or turn the power OFF and
ON.
Change the TC setting value during RAM operation.
Enable the MELSEC data link function service with CW
Configurator.
Check the specified time out value.
Check the specified I/O number.
Check the specified logical station number.
Check the specified target CPU.
Connect an RCPU.
Acquire label information using the mdGetLabelInfo function
again.
Check the specified label name or the device specification
method.