Mitsubishi Electric MELSEC iQ-R C Series Programming Manual page 190

Controller module
Table of Contents

Advertisement

CCPU_Y_Out_Word_ISR
This function outputs an output signal (Y) in word (16-point) units.
Format
short CCPU_Y_Out_Word_ISR (unsigned short usYNo, unsigned short usSize, unsigned short* pusDataBuf)
Argument
Argument
Name
usYNo
Start output signal
usSize
Output size
pusDataBuf
Data storage destination
Description
• This function outputs (turns ON/OFF) data in the data storage destination (pusDataBuf) from a start output signal (Y)
specified to the start output signal (usYNo) to an output signal (Y) for the size specified to the data size (usSize).
• Specify the start output signal (usYNo) in multiples of 16. (The remainder divided by 16 is discarded.)
• Do not specify an output module controlled by other CPUs to the output signal (usYNo).
If it is specified, no operation is performed to the output module.
• Store output data in the data storage destination (pusDataBuf) in ascending order from the lower bit as shown below.
pusDataBuf
pusDataBuf[0]
pusDataBuf[1]
pusDataBuf[usSize-1]
• Do not execute this function in a routine other than an interrupt routine.
• Do not execute this function to an I/O assignment on which an intelligent function module or an interrupt
module is mounted.
• When data is output to the same output signal (Y) from a routine other than an interrupt routine, the output
value may be overlapped, resulting in an invalid value. Manage the resource so that data is not output to the
same output signal (Y).
WARNING
• If any function in which an invalid argument is specified is executed, an error such as hardware failure (3C02H) may occur
on C Controller module.
• This function does not check the specified argument.
When creating a program, note the following:
An address specified to the write data is a multiple of 2.
An output signal (Y) which is out of the range (excluding 0H to FFFH) is not specified.
3 DETAILS OF FUNCTION
188
3.2 C Controller module dedicated functions for ISR
Description
Specify a start output signal (Y).
(Specify a multiple of 16.)
Specify the output size in word units.
Specify the storage destination of output data.
Description
Data of usYNo+FH to usYNo
Data of usYNo+1FH to usYNo+10H
Data of usYNo+(usSize-1)16+FH to usYNo+(usSize-1)16
IN/OUT
IN
IN