1-1.Function Table Of Controllers - Mitsubishi Electric CITY MULTI PEFY-P22VMS-E-S Data Book

Table of Contents

Advertisement

1. MITSUBISHI ELECTRIC's Air-conditioner Network System. (MELANS)
1-1. Function table of controllers
Model
PAR-
30MAAC
Controllable Groups / Indoors
1 / 16
(Group / Indoor)
*6
■ Operating
ON / OFF
Mode (cool / heat / dry / fan)
Temperature-set
Local Permit / Prohibit
Fan speed
Air-flow direction
■ Status monitoring
ON / OFF
Mode (cool / heat / dry / fan)
Temperature-set
Local Permit / Prohibit
Fan speed
Air-flow direction
Indoor temperature
Filter sign
Error flashing
Error code
Operation hour
■ Scheduling
One-day
Times of ON / OFF per day
Weekly
Times of ON / OFF per week
8 x 7
Annual
Optimized start-up
Auto-off timer
Min. timer setting unit (minute)
■ Recording
Error record
Daily / monthly report
Electricity charge
■ Other
Temp-set limitation by Local R / C
Temp-set limitation by System controller
Operation-lock
Night setback
Sliding temperature control
■ Management (Group / Interlocked)
Ventilation interlock
N /
Group setting
Block setting
Revision of electricity charge
■ Operating on LOSSNAY interlocked (Group / Interlocked)
ON / OFF
N /
Fan speed
N /
Ventilation mode
N / N
■ Status monitoring on LOSSNAY interlocked (Group / Interlocked)
ON / OFF
N /
Fan speed
N /
Ventilation mode
: Each group / Batched ;
: Each group ;
*1. Group setting via wiring between Indoor units with cross-over cable;
*2. Installation possible at Initial setting web browser;
*3. Inter-lock is set at Local remote controller.
*4. This function can be set only on the ME/Simple ME remote controller. This function cannot be used with the MA/Simple MA remote controller.
(But, the validity of this function with the MA/Simple MA remote controller depends on the indoor unit model, and there are possibilities that this function can be used with them.)
*5. Inter-lock is set from system controller. (Except PAC-YT40ANRA)
*6. The maximum number of controllable units decreases depending on the indoor unit model.
*7. For indoor use only.
Local remote controller
PAR-
PAR-
21MAA
F27MEA
YT51CRB
1 / 16
1 / 16
N
N
N
N
N
N
1
8
1 / 1
N
8 x 7
N
N
N
N
N
N
N
5
1
10
N
N
N
N
N
N
N
N
*4
*4
N
N
N
N
N
N /
N /
*1
*1
N
N
N
N
N
N
N /
N /
N /
N
N / N
N
N /
N
N /
N
N
N
N
: Block (for CITY MULTI Indoor unit, not for all Mr.SLIM) ; N : Not Available (Not Used.) ;
CONTROLLER
*7
PAC-
PAC-
PAR-
SE51CRA
FL32MA
1 / 16
1 / 16
1 / 16
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
1 / 1
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
10
N
N
N
N
N
N
N
N
N
N
N
N
*4
N
N
N
N
N
N
N
N
N
N /
N /
N
N
*1
N
N
N
N
N
N
*5
N /
N /
N /
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
System controller
*7
PAC-
AT-50A
YT40ANRA
50 / 50
16 / 50
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
16
N
16 x 7
N
N
N
N
N
N
N
N
5
N
N
N
N
N
N
N
N
*4
N
N
N
N
N
N
N
N
*3
/
/
N
/
N
/ N
N
/
/
N
/ N
N
: Batched only
02-E L
W
ON
ORKS
C7-R Rev.
3 - 3

Advertisement

Table of Contents
loading

Table of Contents