5. ELECTRICAL WIRING DIAGRAMS

GUF-50RDH
3
TM1, TM2 shown in dotted lines are field work.
Be sure to connect the grounding wire.
Breakers and controller switches should be provided by the customer.
GREEN/YELLOW
RED
WHITE
GREEN/YELLOW
M2
ORANGE
PINK
BLACK
SUPPL
AN
Y F
GREEN/YELLOW
PINK
BLACK
RED
M1
WHITE
BLUE
ORANGE
EXHAUST FAN
PURPLE
RED
SV2
PURPLE
RED
RED
SV1
RED
RSV(1k )
RED
GM
YELLOW
ORANGE
ORANGE
LS
YELLOW
YELLOW
W.S
GRAY
TH1(OA)
GRAY
WHITE
TH4(RA)
WHITE
YELLOW
TH3 Gas
pipe
YELLOW
PINK
TH2 Liquid
pipe
PINK
MARK
Symbol Explanation
Symbol
Name
M1
Fan motor (exhaust)
M2
Fan motor (supply)
C
Capacitor
W.S
Water sensor
SV1
Solenoid valve (pressure regulator)
SV2
Solenoid valve (exhaust)
TH1
Thermistor (outdoor air temp. detection)
TH2
Thermistor (pipe temp. detection/liquid)
TH3
Thermistor (pipe temp. detection/gas)
TH4
Thermistor (room air temp. detection)
LEV
Electronic linear expansion valve
RSV
Resistance (solenoid valve)
BROWN
FAN2
CND1
PURPLE
SW4
5
YELLOW
PURPLE
YELLOW
C
BLACK
PINK
FAN4
1
C
FAN1
PINK
RED
SW5
5
WHITE
WHITE
ORANGE
FAN3
1
FUSE1
ZNR9D2
ZNR901
DSA1
7
+
-
CN70
DB901
1
6
CNL
X02
1
CN27
BROWN
RED
PURPLE
LEV
CN4D
ORANGE
PINK
WHITE
CN20
LED3
CN60
CN22
LED2
SW2
LED1
SW14
CN29
SW3
SW12
SW11
CN21
: indicates terminal block,
: board insertion connector or fastening connector of control board.
Symbol
TM1
Terminal block (power supply)
TM2
Terminal block (transmission)
TM3
Terminal block (humidistat, monitor)
SW1
Switch (function selection)
SW2
Switch (capacity code setting)
SW3
Switch (function selection)
SW4,SW5 Switch
SW11
Switch (1st digit address set)
SW12
Switch (2nd digit address set)
SW14
Switch (branch NO. set)
CN32
Connecter (Remote input)
CN51,CN52 Connecter (Remote input/output)
INDOOR UNITS
BROWN
BLUE
CND2
TR
X06
X07
GREEN
/YELLOW
X04
1
3
X05
CNT CN3T
TM3
12
X03
11
10
X08
9
8
X09
CN32
7
CN51
TM2
CN52
1
2
A
B
SW1
S
: connector
Name
Symbol
1, 2
A, B
S
CND1, CND2 Connector (power supply)
X02-X09 Relay
TR
GM
LS
LED1
LED2
LED3
POWER SUPPLY
TM1
220-240V ~50Hz
L
L
N
N
BREAKER(16A)
PE
Humidistat
Uncharged a-contact
240VAC more than 10mA
Operation monitor output
MAX
MIN
AC240V 1A AC220V 100mA
DC 24V 1A DC 5V 100mA
Malfunction monitor output
MAX
MIN
AC240V 1A
AC220V 100mA
DC 24V 1A
DC 5V 100mA
MA Remote Controller
<PAR-21MAA>
M-NET transmission cable
To Outdoor Unit , Refrigerant Distributor
Fresh Master
ME Remote controller
< PAR-F27MEA>
Shield wire
Name
Remote control terminal
M-NET transmission terminal
Shield
Transformer
Damper motor
Limit switch
Power supply monitor
MA Remote controller
Power supply monitor
M-NET Power supply monitor
C7-R Rev.
5. E L E C T R I C A L W I R I N G D I A G R A M S