PRINT POSITION OFFSET IN CR OPERATION DIRECTION
Symptom
The image is offset in the main scanning direction (left and right margins
are not equal) and the left or right edge of the image is cut off.
Main scanning line (CR operation) direction
Figure 4-7. Print Position Offset in CR Operation Direction
Cause
Paper load position offset
Paper settings of main unit or printer driver settings are inappropriate.
Print start position process adjustment value deviation
Paper feeding failure
PW Sensor is dirty or has deteriorated.
PW Sensor adjustment value incorrect
CR Scale dirty, damaged, or defective
Troubleshooting
Troubleshooting procedure