Interface Electronics Specifications; Interface Configuration - Tandon TM-100-1 Operating And Service Manual

Disk drives 48 tracks per inch
Hide thumbs Also See for TM-100-1:
Table of Contents

Advertisement

3.3
INTERFACE ELECTRONICS SPECIFICATIONS
All interface signals are TTL compatible. Logic true (low) is
+
0.4 V (minimum)
.
Figure 3-2 illustrates the interface
configuration. The maximum interface cable length is ten (10) feet.
TR UE
DR
IV
ER
TWI ST
ED PAIR
TRANSMI
SSION LINE
~
10
FEE
T
Figure 3-2
Interface Configuration
SV
I
RECE
I
VER
I
I
I
I
150 OHMS
74
LS04
OR
EQUIVA
LE
NT
It is recommended that the interface cable be flat ribbon
cable,
with a characteristic impedance of 100 ohms (or
equivalent twisted pairs).
Interface connector pin assignments and power connector pin assignments are given in Table 3-2 and Table
3-3.
3-3