Download Print this page

Yamaha REV-1 Operating Manual page 10

Digital reverberator / remote control unit

Advertisement

REAR
PANEL
(D INPUT (Input XLR Connector)
The balanced XLR (pin l-ground; pin 2-hot;
pin 3-cold)
level is +4dB nominal,
and head-
room is +144В,
with a maximum input level of
+20dB,
input impedance not less than 10 kohms.
@ REM/COMP (Remote Control/Computer Switch)
Switch to "REM" to use the remote control unit,
and to "COMP" to use a computer via the RS-
232C cable.
@ REMOTE (Remote Control Connector)
This connector
is exclusively
for the remote
control unit.
48
ее
Ф
remote control cable
@
v
After connecting,
lock with this part. bh. @ |
(D-sub 9 2
@ TO COMPUTER
(Connector for Computer
Interface)
D-sub 25 Pin connector,
RS-232C compatible.
(FUSE
U.S. Version
3A 250V
11.254 250V
(6 OUTPUT L апа R (Output XLR Connectors)
General
Version
The balanced XLR (pin 1-ground; pin 2-hot;
pin 3-cold),
level is +4dB nominal,
with a
maximum output level of +18dB, output imped-
ance-
less than or equal to 600 ohms.
9
@ INT/EXT (Word Clock Switch)
Used to switch
between
the internal
word clock
(44.1 kHz) or an external word clock
(through
BNC input).
The internal word clock is
assumed automatically
if no sampling clock
is
fed to the BNC input;
even
if this switch
is
on "EXT"
(external).
@ A IN/D IN (Analog/Digital Input
Selection Switch)
At "A IN", analog input is accepted,
and at "D
ІК", digital
input is accepted.
@ EXT. W. CLK (External Word Clock Connector)
This
terminal
can be connected with the word
clocks
(sampling clocks) of function genera-
tors and other digital
equipment
at the TTL
level.
The range of the frequency is from 30
kHz to 46.75 kHz (alializing distortion
results when analog input is selected rather
than digital
input with a sampling
frequency
of under 40 kHz).
In this case,
data such as
R/T,
Delay 1, is automatically
adjusted
to the
micro-computer.
(0 DIGITAL 1/0 (Connector for Digital
Input/Output)
This
is used when an optional
unit circuit
board
is mounted
for digital
input and output.
(D-sub 37 Pin)
@ AC~
(AC Inlet)
U.S. Version
AC 110V ~120V
AC 220V ~240V
General
Version
Note : Optional
features
and computer
inter-
faces are now being planned
for future sale.