Cleaning The Flue Passageway - Stanley K50 Installation And Operating Instructions Manual

Wood pellet stove
Table of Contents

Advertisement

Figure 30 Side Cover removal
Remove the front cleaning door and the side
cleaning cover and vacuum clean the area behind
the cleaning doors and refit making sure the doors
are fitted correctly

13.5 Cleaning the flue passageway.

To perform this cleaning it is necessary to remove
the front vermiculite (refractory material) from
the inside of the combustion chamber, remove it
from the fittings that are in the smoke deflector, if
necessary remove the side vermiculites. Then
remove the smoke deflector, remove its fittings in
the holes in the combustion chamber. With the
help of a small steel brush (a 20-25mm diameter
steel brush is recommended) remove the ashes in
the flue passageway that are difficult to access
and the more ingrained ashes that are found in
the walls of the combustion chamber. Use the
vacuum cleaner to remove dirt from inside the
combustion chamber. Replace the parts back in
reverse order.
Figure 31Vermiculite removal
Figure 32Smoke deflector removal-1
Figure 33Flue passageways