Spartherm Premium Assembly And Operating Manual page 37

Table of Contents

Advertisement

. WARNING!
Risk of fire resulting from non-adherence to safety
distances!
using the unit creates very high temperatures. smoke and
sparks may escape when opening the firebox door. sensitive
items near the unit may become damaged or deformed, may
melt or catch fire.
4 ensure that the necessary safety distances are observed at
all times.
4 ensure that flammable objects and materials (e.g. furniture,
textiles) are located at a sufficient distance from the unit.
A Wall
B Floor covering made of non-flammable material (if
required)
C Flammable object (e.g. armchair)
X radiation area – minimum distance from flammable
objects and materials.
5.1 / 1
300
A
radiation range (X):
premium V-1V-87h – 2300 mm
premium V-Fd-87h – 1790 mm
5.1 / 2
radiation range (X):
premium V-2l-55h – 1200 mm front, 1000 mm side
premium V-2r-55h – 1200 mm front, 1000 mm side
premium V-2l-68h – 1400 mm front, 1200 mm side
premium V-2r-68h – 1400 mm front, 1200 mm side
premium V-2l-80h – 2100 mm front, 1300 mm side
premium V-2r-80h – 2100 mm front, 1300 mm side
lean 2l-70h – 1100 mm front, 800 mm side
lean 2r-70h – 1100 mm front, 800 mm side
B
5.1 / 3
X
A
C
radiation range (X):
premium A-3rl-60h – 1180 mm front, 880 mm side
premium A-3rl-80h – 1180 mm front, 900 mm side
premium A-u-50h – 850 mm front, 1000 mm side
premium A-u-70h – 850 mm front, 1100 mm side
lean 3rl-70h – 800 mm front, 800 mm side
Assembly and operating manual | Premium & Lean | 06.2023 | en
300
500
A
B
X
C
300
500
B
X
C
37

Advertisement

Table of Contents
loading