Led Error Indication - Omron F3S-TGR-CL2 Installation And Operation Manual

Finger and hand protection sensor
Table of Contents

Advertisement

Receiver Diagnostic information

16-1-3 LED error indication

Disposition of indicator
RX
72
Name of indicator
POWER
Green
STATUS
Yellow
GUARD
Green
BREAK
Red
INTERLOCK
Yellow
Description of Error
Low supply voltage
Check if power-supply is within the specification
(24 VDC±20%)
Control logic fault
Remove and reapply power. If the error is still
present, contact your local Omron distributor
Error in Safety Outputs Check the wiring of the OSSD outputs.
Muting lamp connec-
Check the connection of the muting lamp and/or
tion fault of muting
check the condition of the muting lamp
lamp defective
Mutual light interfer-
Check the presence of ambient light sources
ence
close to the protection field. Use coding option
or remove the light source.
Error in floating blank-
Check the position of the blanking object. Make
ing mode. Object out-
sure it is inside the blanking area.
side the blanking area
or missing fixed blank-
ing object
EDM fault
Check and correct EDM wiring.
Error in pre-reset func-
Pre-reset condition was not met. Corect place-
tion
ment of the pre-reset switch to keep timing
within the specification.
Section 16-1
Colour
Corrective action needed

Advertisement