Safety distance and beam heights in access guarding

8-3
Safety distance and beam heights in access guarding
!WARNING
22
Direction of
approach
Additional countermeasures may be necessary to prevent access to the dan-
gerous area from above, below, the sides or the rear of the machine.
According to EN999 and EN294:
Resolution
Lowest beam above
reference plane
14 mm
In accordance with
EN 294
35 mm
In accordance with
EN 294
The height of the protective field "H" above the reference plane and the reso-
lution "d" of the F3S-TGR-Cl system have the following relationship:
S =
(K x T) + C
For K and T please refer to the previous chapter
C =
S =
(2000 mm x T) + 8 x (d - 14)
S
H
L
Highest beam above
reference plane
In accordance with
EN 294
In accordance with
EN 294
8 x (d - 14)
d = resolution of the F3S-TGR-CL system
Section 8-3
Additional
amount C
(see formula)
0 mm
168 mm