Specification
50
Safety category
Safety Integrity Level
Performance level (PL)
Mean time to dangerous fail-
ure (MTTFd)
Diagnostic Coverage (DC)
Mean time to repair (MTTR)
PFH
Proof test interval
Response time of F3S-TGR-CL__-014-____ system
Part No.
F3S-TGR-CL__-014-0150
F3S-TGR-CL__-014-0300
F3S-TGR-CL__-014-0450
F3S-TGR-CL__-014-0600
F3S-TGR-CL__-014-0750
F3S-TGR-CL__-014-0900
F3S-TGR-CL__-014-1050
F3S-TGR-CL__-014-1200
F3S-TGR-CL__-014-1350
F3S-TGR-CL__-014-1500
F3S-TGR-CL__-014-1650
F3S-TGR-CL__-014-1800
F3S-TGR-CL__-014-1950
F3S-TGR-CL__-014-2100
F3S-TGR-CL__-014-2250
F3S-TGR-CL__-014-2400
Response time of F3S-TGR-CL__-035-____ system
Part No.
F3S-TGR-CL__-035-0150
F3S-TGR-CL__-035-0300
F3S-TGR-CL__-035-0450
F3S-TGR-CL__-035-0600
F3S-TGR-CL__-035-0750
F3S-TGR-CL__-035-0900
F3S-TGR-CL__-035-1050
F3S-TGR-CL__-035-1200
F3S-TGR-CL__-035-1350
F3S-TGR-CL__-035-1500
F3S-TGR-CL__-035-1650
F3S-TGR-CL__-035-1800
Conformity
F3S-TGR-CL2 system is suitable for safety control
systems up to Category 2 acc. EN954-1 (1996)
F3S-TGR-CL4 system is suitable for safety control
systems up to Category 4 acc. EN954-1 (1996)
F3S-TGR-CL system is suitable for up to SIL 3 per
IEC 61508
F3S-TGR-CL2 system is suitable for safety control
systems up to Performance level c acc. EN ISO
13849-1
F3S-TGR-CL4 system is suitable for safety control
systems up to Performance level e acc. EN ISO
13849-1
450 years
High acc. EN ISO 13849-1
8 hours
-09
2.5 * 10
Every 20 years
Number of
modules
beams
7
21
7
42
7
63
7
84
7
105
7
136
7
147
7
168
7
189
7
210
7
231
7
252
7
273
7
294
7
315
7
336
Number of
modules
beams
4
8
4
16
4
24
4
32
4
40
4
48
4
56
4
64
8
72
8
80
8
88
8
96
Section 14-1
Response time
ON OFF
OFF ON
18 ms
138 ms
23 ms
135 ms
29 ms
131 ms
35 ms
127 ms
40 ms
123 ms
46 ms
119 ms
52 ms
116 ms
58 ms
112 ms
63 ms
108 ms
69 ms
104 ms
75 ms
100 ms
80 ms
97 ms
86 ms
93 ms
92 ms
93 ms
97 ms
98 ms
103 ms
104 ms
Response time
ON OFF
OFF ON
14 ms
141 ms
16 ms
139 ms
19 ms
138 ms
21 ms
136 ms
23 ms
135 ms
25 ms
133 ms
27 ms
132 ms
29 ms
131 ms
32 ms
129 ms
34 ms
128 ms
36 ms
126 ms
38 ms
125 ms