Cross Talk Mitigation - Omron F3S-TGR-CL2 Installation And Operation Manual

Finger and hand protection sensor
Table of Contents

Advertisement

Cross Talk Mitigation

9-2
Cross Talk Mitigation
24
The following graphs show the minimum distance d for a operating range R of
up to 20 m:
2
Type 2
1,5
1
0,5
0
0,1 0,2 0,5 1
2
3
-0,5
-1
-1,5
-2
1
Type 4
0,8
0,6
0,4
0,2
0
0,1 0,2 0,5 1
2
3
-0,2
-0,4
-0,6
-0,8
-1
To mitigate interference from other light curtains, the F3S-TGR-CL system
has two possible scan codes, A and B. The transmitter and receiver units
must be set to the same scan code for the receiver to enter the MACHINE
RUN state.
Scan Code A
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20
Operating range R [m]
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20
Operating range R [m]
Scan Code B
Section 9-2