Access to the selector switches
6-1-2

Transmitter selector switch settings

Selector switches 5 - 8 are not used in the transmitter.
Switch Position
Setting
1
OFF
ON
2
OFF
ON
3
OFF
ON
4
OFF
ON
Please refer to the table below for the range setting:
SW-1
SW-2
OFF
OFF
OFF
ON
ON
OFF
ON
ON
Function
RANGE SETTING
X
SHORT RANGE X
RANGE SETTING
X
LONG RANGE
CODE SETTING
NO CODING
CODING
CODE SELECTION CODE A
CODE B
Range selected
NOT ALLOWED
LONG RANGE
SHORT RANGE
NOT ALLOWED
Section 6-1
Default
X
X