Omron F3S-TGR-CL2 Installation And Operation Manual page 32

Finger and hand protection sensor
Table of Contents

Advertisement

Safety Outputs (OSSDs) waveform
18
F3S-TGR-CL in MACHINE STOP state, coding selected
OSSD1
OSSD2
Test pulse ≤ 70 µs
t
1
Test interval ≤ 33 ms
t
2
t
1
t
2
Section 7-2