Quad 2-Input Multiplexer 1820-0616; Data Selectors/Multiplexers 1820-0640 - HP 5340A Operating And Service Manual

Frequency counter
Hide thumbs Also See for 5340A:
Table of Contents

Advertisement

Model 5340A
Theory of Operation
Figure 4-24. Quad 2-Input Multiplexer 1820-0616
4-56. This IC (Figure 4-25) selects 1 of 16 data sources and can be used for parallel-to-serial
conversion, multiplexing, or as a five-variable function generator. Four data select lines are used
to select which input is routed to the output. The select lines perform binary decoding. When the
strobe input is driven low, the multiplexers are enabled. The truth table shows the logic require-
of the multiplexers. For example, when the strobe is low, and the data select lines are
ABCD, then input E3 is gated to the output W line.
Figure 4-25. Data Selectors/Multiplexers 1820-0640
DATA INPUTS
DATA SELECT
9
10
13
A
\
OUT- DATA
DATA INPUTS
PUT SELECT
POSITIVE LOGIC
+
+
+ A B C D E ~
+ A B C D E ~
+
+
+
+
+
+
+
+
+
4-17