Philips VueLink M1032A Service Booklet page 169

Table of Contents

Advertisement

Step 3: Prepare the free analog cable
Note
Free Analog Device Information
(45 Minutes)
1. Connect the black and white wires that are twisted together to the ELSA/
EAS Analog ground (pin 18). Do NOT separate these wires.
2. Connect the thick black wire, or the copper shield, to the case resp. ground
on the device (ELSA/EAS pin 1).
If there is a conductive connection from the copper shield, via the connector, to the
case resp. ground, then the black wire does not need to be connected.
3. Connect the colored wires to the analog output connector on the external
device. The respective channels for each wire color are given in the following
table.
VueLink Free Analog Cable
Channel
Wire Colours
---
Black and White
(twisted)
---
Black (thick)
Wave 1
Brown
Wave 2
Red
Numeric 1
Orange
Numeric 2
Yellow
Numeric 3
Green
Numeric 4
Blue
1. This wave is optional for ELSA. Please select another waveform, if CO
available on your device.
Engström ELSA/EAS Anesthesia System
Designation
Analog ground
Shield
1
CO
Concentration
2
Airway Pressure
O
Concentration
2
Expired Minute
Volume
Total Fresh Gas Flow
-
Concentration is not
2
ELSA/
EAS PIN
18
1
5
15
3
4
17
-
169

Advertisement

Table of Contents
loading

Table of Contents