Genie Screw Drive User Manual
Genie Screw Drive User Manual

Genie Screw Drive User Manual

Includes remote control and series ii electronics screw drive series

Advertisement

IS, ISL, IC, H
Series
Includes
and SERIES II Electronics
Included Wall Control MUST be installed prior to operation of this Garage
Door Operator
Safe-T-Beam
®
Safety Reverse System Must be installed to close door
NOTE: Your Residential Operator comes with a Rail Assembly
which is standard for up to a 7 foot 6 inch high door. An extension
kit for an 8 foot high door is available.
For Answers and Assistance:
1.800.354.3643
or visit www.geniecompany.com
SAVE THIS MANUAL FOR FUTURE REFERENCE
3511035556
¤
®
Remote Control

Advertisement

Table of Contents
loading

Summary of Contents for Genie Screw Drive

  • Page 1 IS, ISL, IC, H Series Includes and SERIES II Electronics Included Wall Control MUST be installed prior to operation of this Garage Door Operator Safe-T-Beam ® Safety Reverse System Must be installed to close door NOTE: Your Residential Operator comes with a Rail Assembly which is standard for up to a 7 foot 6 inch high door.
  • Page 2: Pre-Installation Check List

    The Genie Company recommends that you read and fully understand all information and instructions contained herein before choosing a “do-it-yourself ” installation. Any questions should be directed to the Genie Company or an authorized Genie Dealer. ( The issue numbers below refer to the circled numbers in the illustrations on page 3.
  • Page 3: Typical Sectional Door Installation

    TYPICAL SUPPORT BRACKET 36” POWER CORD 120V GROUNDED OUTLET EXTENSION SPRING TORSION SPRING TYPICAL 1-PIECE DOOR INSTALLATION TYPICAL SECTIONAL DOOR INSTALLATION SAFE-T-BEAM SECTIONAL DOOR ADDED HEADER BRACKET MOUNTING BOARD BRACES ® 1-PIECE DOOR...
  • Page 4: Table Of Contents

    TABLE OF CONTENTS SECTION PAGE PRE-INSTALLATION CHECK LIST ....2-3 TOOLS REQUIRED ......4 SAFETY FEATURES .
  • Page 5: Operational Features

    POWER HEAD EXPLODED VIEW [ 1 ] Power Head Assembly POWER HEAD PARTS LIST Item Part Name Power Head Assembly Cover (By Series/Model) Front Plate Assembly Light Socket Motor Parts Receiver Assembly Capacitor (By Series/Model) Opto Wheel Opto-Luctor Assembly Sequencer Assembly Circuit Board Bracket Transformer OPERATIONAL FEATURES...
  • Page 6: 1-Piece Rail Hardware Exploded View

    1-PIECE RAIL HARDWARE EXPLODED VIEW [ 2 ] 1-Piece Rail & Screw Assembly NOTE: The operator will not function properly unless the Safe-T-Beam sensors are installed and the force controls adjusted. PARTS LIST Item Part Name Power Head Assembly (See page 5) Rail Assembly (1 piece) Rail Assembly (3 piece) First Rail Section...
  • Page 7: 3-Piece Rail Hardware Exploded View

    3-PIECE RAIL HARDWARE EXPLODED VIEW [ 3 ] 3-Piece Rail & Screw Assembly NOTE: The operator will not function unless the Safe-T-Beam installed and the force controls are properly set. PARTS LIST Item Part Name Wall Console #6 x 1-1/4” Pan Head Screw Entrapment WARNING Label Safe-T-Beam (STB) System Sensor (Green LED) Safe-T-Beam (STB) System Source (Red LED)
  • Page 8: 34 #6 X 1-1/4" Pan Head Screw

    PARTS IDENTIFICATION NOTE: Accessories vary by model. FASTENERS - Shown full size. See Parts List for description. 1/4" Shoulder bolt w/flange 1/4" Flange nut Carriage stop (not to scale) 5/16" Shoulder bolt w/flange 5/16" Flange nut Collar Clip #8-32 x 3/8" Hex head screw FOR HELP-1.800.354.3643 OR GENIECOMPANY.COM 1/4"...
  • Page 9: Safety Information

    SAFETY INFORMATION OVERVIEW OF POTENTIAL HAZARDS Garage doors are large, heavy objects that move with the help of springs under high tension and electric motors. Since moving objects, springs under tension, and electric motors can cause injuries, your safety and the safety of others depend on you reading the information in this manual.
  • Page 10: Bumper

    SECT 1—MAIN ASSEMBLY OPEN BLUE PARTS BAG NOTE: 3-piece rail assembly is for doors up to and including 7 feet 6 inches high. An extension for 8 feet doors is available. 1. Set power head so that front panel (with end of shaft and rail attachment flange) is facing up.
  • Page 11: Main Assembly

    MAIN ASSEMBLY 6. Attach “middle” rail section [3B]. • Select “middle” rail section. (This section looks identical on both ends with each set of holes being about 4 inches apart.) Fig. 1-6. • Find arrows stamped into side of rail. Fig.
  • Page 12 MAIN ASSEMBLY • Slide a collar [11] over exposed end of screw on “middle” rail as far as it will go. Fig. 1-8. • Engage “hook” on “middle” rail with “hook” on “first” rail section. Fig. 1-9. • Slide collar toward power head so that it now covers hooks.
  • Page 13: 5/16" X 3/4" Hex Head Bolt

    MAIN ASSEMBLY NOTE: If installing an extension kit for an 8 feet high door, refer to the instructions included with the extension kit now. 7. Attach “end” rail section [3C]. • Attach “end” rail in same way as “middle” rail (step 5).
  • Page 14 MAIN ASSEMBLY OPEN GREEN PARTS BAG Screws for attaching light cover are included in this bag. Please set aside for use later. 14. Attach emergency release knob, cord and tag. • Tie an overhand knot in one end of emergency release cord [17]. –...
  • Page 15 SECT 2—INSTALLATION NOTE: There are differences in installations depending on which type of door you have. These differences are explained throughout this section. Please note those steps which are applicable to your particular door. REFER TO PAGES 2 & 3. There are two basic types of residential garage doors.
  • Page 16: Installation

    INSTALLATION 2. Finding highest point of travel. • While raising garage door manually, watch top edge of door to see where it reaches its highest point. This is called “highest point of travel.” Fig. 2-2. • A locking pliers can be used to hold the door in position by clamping it onto the rail.
  • Page 17 INSTALLATION NOTE: If torsion spring interferes with your final location, mark bracket location 2-1/2" or 6" above torsion spring depending on garage door type. 4. Check mounting location for strength. Header bracket must be attached to framework of garage. Fig. 2-5. •...
  • Page 18 INSTALLATION 7. Attaching rail to header bracket. • Gently set power head on garage floor while leaning rail strap against header bracket. (It is recommended that you place a piece of cardboard or similar material between power head and floor to prevent scrapes and scratches to power head.) NOTE: It may be necessary to support power head above floor.
  • Page 19: Mounting Straps

    INSTALLATION 8. Mounting power head. • Raise power head and support it high enough that you can manually raise garage door fully open. • Line up power head and rail with center of door. Fig. 2-9. • Keeping power head centered, mount to ceiling: –...
  • Page 20: Mounting Door Bracket

    Unauthorized improper use of these attachment systems could void your warranty. WHEREVER POSSIBLE—USE DOOR BRACKET SUPPLIED WITH YOUR GENIE OPERATOR. a. Fasten door bracket using 3 self-drilling screws [47]. 1/4" x 2" Lag screw FOR HELP-1.800.354.3643 OR GENIECOMPANY.COM WOODEN ONE-PIECE...
  • Page 21 INSTALLATION OPEN YELLOW PARTS BAG 10. Attach door arms [23] and [26]. • For sectional doors. – Connect short leg of curved arm to door bracket. Fig. 2-14. – Use clevis pin [24] and cotter pin [25]. Fig. 2-14. – Connect straight arm to carriage. –...
  • Page 22: Safe-T-Beam Installation

    SECT 3—SAFE-T-BEAM WARNING There should be no electrical power to the operator while installing Safe-T-Beam System ® wires. If you have plugged in the power cord–UNPLUG IT NOW. NOTE: Operator will not close door automatically unless the Safe-T-Beam ® System is installed. 1.
  • Page 23: Safe-T-Beam

    SAFE-T-BEAM ® INSTALLATION CAUTION Staples which are too tight can cut or pinch wires. Cut or pinched wires can cause the STB System to stop working. When using the insulated staples, make sure you fasten them only as tightly as needed to hold the wire snugly. •...
  • Page 24 SECT 4—WALL CONTROL INSTALLATION WARNING Power must be removed before attaching wires. Be sure ends do not touch each other or other terminals. CAUTION • Use of any other wall control can cause the door to operate unexpectedly and the light not to work.
  • Page 25: Wall Control

    WALL CONTROL OPERATIONAL FEATURES 1. Wall console. Fig. 4-5. A. Vacation locking switch. – Lock disable all controls after door closes.. – Unlock allows all controls to work normally. NOTE: Carriage must stay in contact with “CLOSE” limit switch in order for the vacation locking switch to work.
  • Page 26: Connecting Power

    SECT 6—CONNECTING POWER WITH GROUNDED PLUG: WARNING To reduce the risk of electrical shock, this equipment has a grounded type plug that includes a third (grounding) pin. This plug will only fit a grounded type outlet. If you do not have a grounded outlet, contact a qualified electrician to install one.
  • Page 27 SECT 7—SETTINGS CAUTION Door opens rapidly • Keep clear of door and its path. • Keep ladder to side of power head to prevent being hit by moving parts. Be sure and set force adjustments at minimum required to operate door. 1.
  • Page 28: Settings

    SETTINGS (CONTACT REVERSE) Limit switch adjustments must be completed before running contact reverse test. 1. Test contact reverse. • Open door using wall control. • Lay 2" x 4" board on floor in center of garage door opening. Fig. 7-3. •...
  • Page 29: Programming Remote Controls

    SECT 9—PROGRAMMING REMOTE CONTROLS PROGRAMMING REMOTE CONTROLS NOTE: Each remote device must be programmed separately WARNING Moving door can cause serious injury or death. • Keep people clear of opening while door is moving. • Do not allow children to play with remote controls.
  • Page 30: Transmitter Compliance Statement

    KEEP GARAGE DOORS PROPERLY BALANCED. See Owner's Manual. An improperly balanced door increases the risk of severe injury or death. Have a Genie Factory Authorized Dealer make repairs to cables, spring assemblies, and other hardware. SAVE THESE INSTRUCTIONS.
  • Page 31 YEARLY MAINTENANCE Drive Screw • Lubricate drive screw. – Use GENIE GLU3 lubricant. CAUTION Use only GENIE GLU3 lubricant, because other lubricants may damage operator. TROUBLESHOOTING SELF-DIAGNOSTIC TROUBLESHOOTING SOURCE ( RED LED ) SENSOR ( GREEN LED ) INDICATED CONDITION...
  • Page 32: Maintenance & Troubleshooting

    MAINTENANCE & TROUBLESHOOTING Use this guide to correct problems with your door operator. If these solutions do not work, call Customer Service. CAUTION Use only with included SERIES II wall control Use of any other wall control can cause the door to operate unexpectedly and the light not to work.
  • Page 33: Wiring Diagram

    SECT 11—WIRING DIAGRAM CAUTION Opening cover could cause electrical shock. Remove power from operator prior to removing cover. PRIMARY SEQUENCER CLOSE / CERRAR / FERMER SECUENCIADOR PRIMARIO SEQUENCEUR OPEN / ABRIR / OUVRIR PRIMAIRE WHITE WHITE WHITE GREEN BLACK LIGHTS LUZES LAMPES BLUE...
  • Page 34 If we send replacement parts for your Genie product, we may use new or reconditioned replacement parts. If we choose to replace your Genie product, we may replace it with a new or reconditioned one of the same or similar design.
  • Page 35: Accessories Order Form

    Screw Drive Extension Kit - Eighteen inch Extension to increase travel of Screw Drive Operator to accommodate eight foot door. Juego de extensión deslizante de Screw Drive - Una extensión de 18 pulgadas para aumentar la carrera de un abridor deslizable de tornillo, para acomodar una puerta de 8 pies (2,43 m.).

Table of Contents