Display Operation in Run Mode
Operators display their status on the integrated display. Each time the operator
runs, stops, reverses or refuses to run, the display will indicate why the action did, or did
not, take place.
Once an error code has been generated, the operator will continue to display the
error code while the operator is not running. This error code can be cleared by pressing
the STOP button or STOP key on the keypad. The error code will automatically clear
when the operator stops at the down limit. Error codes will continue to be stored in the
operator's Error Code Memory after they have been cleared from the display in
the Run Mode.

Error Codes

To aid in troubleshooting problems, operators include an error code memory
that stores the last 10 error events. These codes are stored with or without power. The
last error code detected is also displayed on the LCD until the stop button or key is
pressed or the operator stops at the down limit.
The error code memory stores the last 10 error codes in sequence. Once 10 codes are
stored, the oldest code is erased to make room for the newest code. These codes are
displayed in calibration mode. The display will flash the number of the error code and
the 2-digit error code followed by a description of the error code. Fig. 1 & 2.
Section 8: Troubleshooting
www.geniecompany.com
OPEN
ERROR CODE 1 41
CLOSE
STOP
CAL
SET
SCROLL
RUN
CLEAR
SCROLL
Figure 1
OPEN
REV ONE BUTTON
CLOSE
STOP
CAL
SET
SCROLL
RUN
CLEAR
SCROLL
Figure 2