MENU OPTION
TCP/IP
1
Ping Host
System
11
Reboot System
Port
21
Reset Port
22
Local Loop
Back Test
23
Remote Loop
Back Test
VDSL
31
Update Remote
Firmware
32
Reconnect
Host IP
Address
Port Number
System Maintenance 1

Table 9-G System Maintenance Menu Diagnostic

FIELD
Enter 1 to ping any machine (with an IP address). Enter its IP address in
the Host IP Address field below.
Enter 11 to reboot the VES-1000 Series switch.
Enter 21 and then the port number in the Port Number field below to reset
the port.
Use these loop back tests to determine if there's a problem with the VES-
1000 Series switch or the telephone line to the VDSL modem. Enter 22 and
then the port number in the Port Number field below to do a local (internal
to the switch) loop back test.
Enter 23 and then the port number in the Port Number field below to do a
remote (from the switch to the VDSL modem) loop back test.
Enter 31 to manually update the subscriber's VDSL modem firmware; you
may also do this automatically in SMT menu 2.
Enter 32 to drop and bring up the VDSL connection. You may do this if you
are experiencing problems with a subscriber's VDSL connection.
If you entered 1 above, then enter the IP address of the machine you want
to ping in this field.
If you entered 21, 22 or 23 above, then enter the port number in this field.
VES-1000 Series Ethernet Switch
DESCRIPTION