possible to modify the value of parameter
P10 (Fig. 8.35):
05 = M275V.28 SR
Fig. 8.35
• Press 10 or 11 (Fig. 8.31) to confirm the
value entered and return to the list of pa-
rameters (Fig. 8.34).
• Press the 15 button (Fig. 8.31) to exit "pro-
gramming mode".
• Enter "programming mode" by holding
down buttons 15 and 16 for 5 seconds at
the same time (Fig. 8.31).
• Press 10 or 11 and hold until the LCD dis-
play shows the code P02, indicating entry
into "parameter P02" (Fig. 8.36).
Fig. 8.36
• By using buttons 13 or 14 (Fig. 8.31) it is
possible to modify the value of parameter
P02 (Fig. 8.37).
78 = Default
83 = Correct
Fig. 8.37
ADVANCED COMMISSIONING
RESET
bar
RESET
bar
RESET
bar
• Press 10 or 11 (Fig. 8.31) to confirm the
value entered and return to the list of pa-
rameters (Fig. 8.36).
• Press 10 and hold until the LCD display
shows the code P09, indicating entry into
"parameter P09" (Fig. 8.38).
Fig. 8.38
• By using buttons 13 or 14 (Fig. 8.31) it is
possible to modify the value of parameter
P09 (Fig. 8.39).
03 = Default
01 = Correct
Fig. 8.39
• Press 10 or 11 (Fig. 8.31) to confirm the
value entered and return to the list of pa-
rameters (Fig. 8.38).
• Press 10 and hold until the LCD display
shows the code A00, indicating entry into
"parameter A00" (Fig. 8.40).
Fig. 8.40
• By using buttons 13 or 14 (Fig. 8.31) it is
possible to modify the value of parameter
RESET
bar
RESET
bar
RESET
bar
- 57 -