Settings For Changing The Control Board - Biasi BASICA COND 28S User Manual And Installation Instructions

Wall hung, fanflue, roomsealed, high efficiency gas boiler
Hide thumbs Also See for BASICA COND 28S:
Table of Contents

Advertisement

Fig. 8.30
• By using buttons 13 or 14 (Fig. 8.29) it is
possible to modify the value of parameter
A49:
39 = factory reset
• Press 10 or 11 (Fig. 8.29) to confirm the
value entered and return to the list of pa-
rameters (Fig. 8.30).
• Press the 15 (Fig. 8.29) to exit "program-
ming mode".
8.9
Settings for changing the
control board
When the control board is replaced, it must
be configured for the exact boiler type.
• Enter "programming mode" by holding
down buttons 15 and 16 for 5 seconds at
the same time (Fig. 8.31). The code P00
appears on the display, indicating entry
into "parameter P00" (Fig. 8.32).
16
10
11
Fig. 8.31
- 56 -
ADVANCED COMMISSIONING
RESET
bar
15
14
13
12
Fig. 8.32
• Scroll through the various parameters us-
ing 10 or 11 until the LCD display shows
the message Cod, indicating entry into
"parameter Cod" (Fig. 8.33), and then dis-
plays three dashes "- - -".
Fig. 8.33
• Press the 14 button to set "2 - -", then
press 10 to confirm the 2 and go to the
next segment.
• Press the 14 button to set "2 7 -", then
press 10 to confirm the 7 and go to the
next segment.
• Press the 14 button to set "2 7 5", then
press 10 to confirm the 5 and go back to
the list of parameters.
• The code P10 appears on the display, in-
dicating entry into "parameter P10" (Fig.
8.34).
Fig. 8.34
• By using buttons 13 or 14 (Fig. 8.31) it is
RESET
bar
RESET
bar
RESET
bar