Pluming kit A (Fig. 6.10)
Coaxial Ø 60/100 mm + vertical part Ø 60
mm (flue outlet).
Coaxial Ø 60/100 mm (b) + vertical part
Ø 60 mm (a)
Telescopic coaxial flue
Maximum length (a + b)
This kit allows the products of combustion
to be discharged at a different location to
the air intake to avoid nuisance issues.
90° =--- 0,85 m
ø 60 mm
45° =--- 0,65 m
Fig. 6.10
60 mm elbows and extensions can be add-
ed to the vertical section.
Each additional elbow reduces the overall
acceptable length of the flue system as fol-
lows:
For the bend of 45° (60/100 mm) loss 0.5 m
For the bend of 90° (60/100 mm) loss
For the bend of 45° (60 mm) loss
For the bend of 90° (60 mm) loss
- 38 -
INSTALLATION
0.45-0.95 m
15 m
90° =--- 1 m
ø 60/100 mm
45° =--- 0,5 m
1 m
0.65 m
0.85 m
Pluming kit B (Fig. 6.11) (Fig. 6.12)
Push on type Ø 60 mm vertical plume man-
agement kit
This kit allows the products of combustion to
be discharged at a different location, when
used with the standard horizontal flue kit.
90° =--- 0,85 m
ø 60 mm
45° =--- 0,65 m
Fig. 6.11
Each additional elbow reduces the overall
acceptable length of the flue system as fol-
lows:
For the bend of 45° (60/100 mm) loss 0.5 m
For the bend of 90° (60/100 mm) loss
For the bend of 45° (60 mm) loss
For the bend of 90° (60 mm) loss
The chart Fig. 6.12 gives the maximum al-
lowed value for a + b of (Fig. 6.11).
90° =--- 1 m
ø 60/100 mm
45°
=--- 0,5 m
1 m
0.65 m
0.85 m