Sequence for setting the K coefficient
• Enter "programming mode" by pressing
the 15 and 16 keys simultaneously for 5
seconds (Fig. 8.9). The code P00 appears
on the display, indicating entry into "pa-
rameter P00" (Fig. 8.10).
16
10
11
Fig. 8.9
Fig. 8.10
• Scroll through the various menus by
pressing the keys 10 (back) or 11 (for-
ward), until the LCD display shows the
code P07, indicating entry into "parameter
P07" (Fig. 8.11).
Fig. 8.11
• Press 14 (Fig. 8.9) to show the value of
parameter P07 on the LCD display (Fig.
8.12).
ADVANCED COMMISSIONING
15
14
13
12
RESET
bar
RESET
bar
Fig. 8.12
• By using buttons 13 or 14 (Fig. 8.9) it is
possible to modify the value of parameter
P07:
00 = Probe disabled (preset)
01 = Probe enabled (12kOhm)
02 = Probe enabled (10kOhm)
• Press 10 or 11 (Fig. 8.9) to confirm the
value entered and return to the list of pa-
rameters Fig. 8.11.
• Press the 15 button (Fig. 8.9) to exit "pro-
gramming mode".
• Press 11 and hold until the LCD display
shows the code P08, indicating entry into
"parameter P08" (Fig. 8.13).
Fig. 8.13
• Using buttons 13 or 14 it is possible to
change the value of parameter P08 from
a minimum of 1.0 to a maximum of 3.0
based on the selected curve of the K coef-
ficient in Fig. 8.7 (the value read on the
display corresponds to the decimal values
of the K coefficients).
• Press 10 or 11 (Fig. 8.9) to confirm the
value entered and return to the list of pa-
rameters (Fig. 8.13).
• Press the 15 button (Fig. 8.9) to exit "pro-
gramming mode".
RESET
bar
RESET
bar
- 51 -