Biasi BASICA COND 28S User Manual And Installation Instructions page 59

Wall hung, fanflue, roomsealed, high efficiency gas boiler
Hide thumbs Also See for BASICA COND 28S:
Table of Contents

Advertisement

• Press 10 (Fig. 8.31) to confirm the value
entered and return to the list of param-
eters (Fig. 8.45).
• Press button 10 and hold until the LCD
display shows the code A21, indicating
entry into "parameter A21" (Fig. 8.47).
Fig. 8.47
• By using buttons 13 or 14 (Fig. 8.31) it is
possible to modify the value of parameter
A21 (Fig. 8.48).
00 = Room thermostat
01 = Remote control
Fig. 8.48
• Press 10 (Fig. 8.31) to confirm the value
entered and return to the list of param-
eters (Fig. 8.47).
• Press button 10 and hold until the LCD
display shows the code A38, indicating
entry into "parameter A38" (Fig. 8.49).
Fig. 8.49
• By using buttons 13 or 14 (Fig. 8.31) it is
possible to modify the value of parameter
ADVANCED COMMISSIONING
RESET
bar
RESET
bar
RESET
bar
A38 (Fig. 8.50).
60 = Default
10 = Correct
Fig. 8.50
• Press 10 (Fig. 8.31) to confirm the value
entered and return to the list of param-
eters (Fig. 8.49).
• Press button 10 and hold until the LCD
display shows the code A50, indicating
entry into "parameter A50" (Fig. 8.51).
Fig. 8.51
• By using buttons 13 or 14 (Fig. 8.31) it is
possible to modify the value of parameter
A50 (Fig. 8.52).
00 = Maintenance period not activated
01 = Maintenance period activated
Fig. 8.52
• Press 10 (Fig. 8.31) to confirm the value
entered and return to the list of param-
eters (Fig. 8.51).
• Press the 15 button (Fig. 8.31) to exit "pro-
gramming mode".
RESET
bar
RESET
bar
RESET
bar
- 59 -