Siemens MindConnect Nano System Manual page 21

Insights hub
Hide thumbs Also See for MindConnect Nano:
Table of Contents

Advertisement

4. Insert the USB stick into the USB port of the MindConnect Nano, e. g. "MindConnect Nano"
During the import of the configuration, the following LED-states are to be expected:
1. MAINT LED flashes orange
2. RUN LED blinks green
3. On-boarding result
RUN LED green: MindConnect onboarded successfully
MAINT LED orange: onboarding failed
The process can take up to 30 minutes. Please do not remove the USB stick
during this time.
5.After successfully importing the configuration, remove the USB stick from the MindConnect
Nano. 6.Check the status of the MindConnect Nano at the Overview.
Result
The connection status in Asset Manager at the overview has changed to "Onboarded". The
configuration of the asset has been transferred to the MindConnect Nano. The connection
between the MindConnect Nano and Industrial IoT is established.
Once MindConnect Nano is onboarded, the connection to your asset is permanent and your
asset for data collection can be configured. This requires configuration of machine data to be
monitored. Any additional configuration (except network configuration) of the connected asset
will automatically be synchronized with your onboarded MindConnect Nano.
The connection to the asset is permanent and can only be cancelled by offboarding. For this
purpose, refer to the
21
Asset Manager
documentation.
Overview of onboarding MindConnect Nano
2.7 Transferring configuration to MindConnect Nano
MindConnect Nano
System Manual 7/2023