Siemens SIMATIC NET RUGGEDCOM M2200F Installation Manual

Rugged ethernet switches
Hide thumbs Also See for SIMATIC NET RUGGEDCOM M2200F:

Advertisement

Quick Links

Edition
04/2022
Installation Manual
SIMATIC NET
Rugged Ethernet Switches
RUGGEDCOM M2200F
https://www.siemens.com/ruggedcom

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC NET RUGGEDCOM M2200F

  • Page 1 Edition 04/2022 Installation Manual SIMATIC NET Rugged Ethernet Switches RUGGEDCOM M2200F https://www.siemens.com/ruggedcom...
  • Page 2 Preface Introduction Installing the Device SIMATIC NET Device Management Rugged Ethernet Switches RUGGEDCOM M2200F Communication Ports Technical Specifications Installation Manual Certification 04/2022 C79000-G8976-1343-09...
  • Page 3 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Table Of Contents

    Accessing Documentation ....................... v Registered Trademarks ......................v Warranty ..........................vi Training ..........................vi Customer Support ........................vi Contacting Siemens ....................... vii Introduction ........................... 1 Feature Highlights ....................1 Description ......................1 Required Tools and Materials ................. 3 Decommissioning and Disposal ................3 Cabling Recommendations ..................
  • Page 5 Table of Contents Power Supply Specifications ................25 Failsafe Relay Specifications ................25 Supported Networking Standards ................ 25 Copper Ethernet Port Specifications ..............26 Fiber Optic Ethernet Port Specifications ............... 27 Operating Environment ..................27 Mechanical Specifications ..................27 Dimension Drawings ................... 28 Certification .........................
  • Page 6: Preface

    SIMATIC NET Glossary The SIMATIC NET Glossary describes special terms that may be used in this document. The glossary is available online via Siemens Industry Online Support (SIOS) at: https://support.industry.siemens.com/cs/ww/en/view/50305045 Accessing Documentation The latest user documentation for RUGGEDCOM M2200F is available online at https:// support.industry.siemens.com.
  • Page 7: Warranty

    Preface Warranty Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
  • Page 8: Contacting Siemens

    Call a local hotline center to submit a Support Request (SR). To locate a local hotline center, visit https://w3.siemens.com/aspa_app/?lang=en. Mobile App Install the Industry Online Support app by Siemens AG on any Android, Apple iOS or Windows mobile device and be able to: •...
  • Page 9 Preface Contacting Siemens viii RUGGEDCOM M2200F Installation Manual, 04/2022, C79000-G8976-1343-09...
  • Page 10: Introduction

    Introduction Feature Highlights Ethernet Ports • Up to 9 x Gigabit Ethernet ports (copper and fiber) • Up to 9 x 100Base-FX Fiber Fast Ethernet ports • 2-port modules for tremendous flexibility • Non-blocking, store and forward switching • Supports many types of fiber (multimode, single mode, bidirectional single strand) •...
  • Page 11 Introduction 1.2 Description Fiber or Copper Ethernet Ports Port Status Indicator LEDs Mode Button RS-232 Serial Console Port (RJ45) Display Mode Indicator LEDs Alarm Indicator LED Power Module Indicator LEDs Figure 1.1 RUGGEDCOM M2200F Communication Ports Ports for communicating with other devices or accessing the RUGGEDCOM M2200F operating system are described in "Communication Ports (Page 21)".
  • Page 12: Required Tools And Materials

    Introduction 1.3 Required Tools and Materials about connecting to the device via the serial console port, refer to "Connecting to the Device (Page 19)". Required Tools and Materials The following tools and materials are required to install the RUGGEDCOM M2200F: Tools/Materials Purpose AC power cord (16 AWG) For connecting power to the device.
  • Page 13: Gigabit Ethernet 1000Base-Tx Cabling Recommendations

    Siemens also does not recommend using copper Ethernet ports to interface with devices in the field across distances that could produce high levels of ground potential rise (i.e. greater than 2500 V), during line-to-ground fault conditions.
  • Page 14: Tamper-Evident Security Seals

    NOTICE Worn, damaged or missing seals must be replaced immediately. Replacement seals are available for purchase from Siemens. For more information, contact a Siemens Sales representative. There are three ways to determine if a security seal has been tampered with: •...
  • Page 15 Introduction 1.6 Tamper-Evident Security Seals RUGGEDCOM M2200F Installation Manual, 04/2022, C79000-G8976-1343-09...
  • Page 16: Installing The Device

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens Canada Ltd. could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 17: General Procedure

    Visually inspect each item in the package for any physical damage. Verify all items are included. Note If any item is missing or damaged, contact Siemens for assistance. Mounting the Device The RUGGEDCOM M2200F is designed for maximum mounting and display flexibility.
  • Page 18: Mounting The Device To A Rack

    Installing the Device 2.3.1 Mounting the Device to a Rack Note For detailed dimensions of the device with either rack or panel hardware installed, refer to "Dimension Drawings (Page 28)". 2.3.1 Mounting the Device to a Rack The RUGGEDCOM M2200F can be secured to a standard 48 cm (19 in) rack using separately purchased rack mount adapters.
  • Page 19: Mounting The Device To A Panel

    Installing the Device 2.3.2 Mounting the Device to a Panel To secure the device to a standard 48 cm (19 in) rack, do the following: Note The device can be ordered with the communication ports located at the front or rear of the device.
  • Page 20: Connecting The Failsafe Alarm Relay

    Installing the Device 2.4 Connecting the Failsafe Alarm Relay To mount the device to a panel, do the following: Place the device against the panel and align the adapters with the mounting holes. Screw Panel Adapter Figure 2.2 Panel Mounting Install the supplied screws to secure the adapters to the panel. Connecting the Failsafe Alarm Relay The failsafe relay can be configured to latch based on alarm conditions.
  • Page 21: Connecting Power

    Installing the Device 2.5 Connecting Power Normally Open Common Normally Closed Figure 2.3 Failsafe Alarm Relay Wiring Connecting Power The RUGGEDCOM M2200F supports a single or dual redundant AC and/or DC power supplies. The RUGGEDCOM M2200F can be equipped with either a screw-type or pluggable terminal block, which provides power to both power supplies.
  • Page 22: Connecting Ac Or Dc Power

    Installing the Device 2.5.1 Connecting AC or DC Power • It is recommended to provide a separate circuit breaker for each power supply module. • Equipment must be installed according to applicable local wiring codes and standards. 2.5.1 Connecting AC or DC Power To connect a single high AC, high DC or low DC power supply to the device, do the following: NOTICE...
  • Page 23 Installing the Device 2.5.1 Connecting AC or DC Power Connect the positive wire from the power source to the positive/live (+/L) terminal on the terminal block. Screw-Type Terminal Block Pluggable Terminal Block Jumper Positive/Live (+/L) Terminal Negative/Neutral (-/N) Terminal (-/N) Surge Ground Terminal Chassis Ground Terminal Chassis Ground Connection Figure 2.4...
  • Page 24: Wiring Examples

    Installing the Device 2.5.2 Wiring Examples Using a #6 ring lug and #6-32 screw, secure the ground terminal on the power source to the chassis ground connection on the device. Make sure the lug is tightened to 1.7 N·m (15 lbf·in). Stainless Steel Stud #6-32 Screw #6 Ring Lug...
  • Page 25 Installing the Device 2.5.2 Wiring Examples Figure 2.6 Single AC Power Supply Figure 2.7 Single DC Power Supply RUGGEDCOM M2200F Installation Manual, 04/2022, C79000-G8976-1343-09...
  • Page 26 Installing the Device 2.5.2 Wiring Examples Figure 2.8 Dual AC Power Supply Figure 2.9 Dual DC Power Supply RUGGEDCOM M2200F Installation Manual, 04/2022, C79000-G8976-1343-09...
  • Page 27 Installing the Device 2.5.2 Wiring Examples Figure 2.10 Dual AC/DC Power Supply RUGGEDCOM M2200F Installation Manual, 04/2022, C79000-G8976-1343-09...
  • Page 28: Device Management

    Device Management This section describes how to connect to and manage the device. Connecting to the Device The following describes the various methods for accessing the RUGGEDCOM M2200F console and Web interfaces on the device. For more detailed instructions, refer to the "RUGGEDCOMROS Configuration Manual"...
  • Page 29: Configuring The Device

    Device Management 3.2 Configuring the Device Name Description Comment RJ45 Male DB9 Female Ring Indicator   The DSR, DCD and DTR pins are connected together internally. The CTS and RTS pins are connected together internally. RI is not connected. Communication Ports Connect any of the available Ethernet ports on the device to a management switch and access the RUGGEDCOM M2200F console and Web interfaces via the device's IP address.
  • Page 30: Communication Ports

    Communication Ports The RUGGEDCOM M2200F can be equipped with various types of communication ports to enhance its abilities and performance. With five available slots, the RUGGEDCOM M2200F supports a variety of one- or two-port fiber or copper Ethernet module of various speeds with up to nine Gigabit Ethernet (1 Gbps) ports. Module Assignment Figure 4.1 Module Assignment...
  • Page 31: Copper Ethernet Ports

    Communication Ports 4.1 Copper Ethernet Ports Port LED Figure 4.2 Port LEDs LED State Description Yellow (Solid) Link established Yellow (Blinking) Link activity No link detected Copper Ethernet Ports The RUGGEDCOM M2200F supports several 10/100Base-TX and 10/100/1000Base- TX Ethernet ports that allow connection to standard Category 5 (CAT-5) unshielded twisted-pair (UTP) cables with Micro-D male connectors.
  • Page 32: Fiber Optic Ethernet Ports

    Communication Ports 4.2 Fiber Optic Ethernet Ports Name Description 10/100Base-TX 1000Base-TX BI_DB+ Transmit Data+ or Bi- Directional Pair B+ Reserved (Do Not Connect) BI_DC+ Transmit Data+ or Bi- Directional Pair C+ Reserved (Do Not Connect) BI_DC- Receive Data- or Bi- Directional Pair C- BI_DB- Transmit Data- or Bi- Directional Pair B-...
  • Page 33 Communication Ports 4.2 Fiber Optic Ethernet Ports For specifications on the available fiber optic Ethernet ports, refer to "Fiber Optic Ethernet Port Specifications (Page 27)". RUGGEDCOM M2200F Installation Manual, 04/2022, C79000-G8976-1343-09...
  • Page 34: Technical Specifications

    Technical Specifications This section details the specifications and operating conditions of the device. Power Supply Specifications The RUGGEDCOM M2200F can be equipped with the following power supplies: NOTICE Electrical hazard – risk of damage to the device Make sure power input to the device is within the specified input range. Power Input Range Internal Fuse...
  • Page 35: Copper Ethernet Port Specifications

    Note • Maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens sales associate when determining maximum segment distances. • All optical power numbers are listed as dBm averages.
  • Page 36: Fiber Optic Ethernet Port Specifications

    All optical power numbers are listed as dBm averages. Typical distance. The maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens sales associates when determining maximum segment distances. Operating Environment The RUGGEDCOM M2200F is rated to operate under the following environmental conditions.
  • Page 37: Dimension Drawings

    Technical Specifications 5.8 Dimension Drawings Dimension Drawings Note All dimensions are in millimeters, unless otherwise stated. Note Dimensional tolerances are in accordance with ISO 2768-mK, unless otherwise stated. 438.15 Figure 5.1 Overall Dimensions RUGGEDCOM M2200F Installation Manual, 04/2022, C79000-G8976-1343-09...
  • Page 38 Technical Specifications 5.8 Dimension Drawings 32.77 21.08 11.68 479.29 470.4 461.0 Figure 5.2 Rack Mount Dimensions RUGGEDCOM M2200F Installation Manual, 04/2022, C79000-G8976-1343-09...
  • Page 39 Technical Specifications 5.8 Dimension Drawings 467.4 275.6 482.6 Figure 5.3 Panel Mount Dimensions RUGGEDCOM M2200F Installation Manual, 04/2022, C79000-G8976-1343-09...
  • Page 40: Certification

    6.1.2 European Union (EU) This device is declared by Siemens Canada Ltd. to comply with essential requirements and other relevant provisions of the following EU directives: EN 62368-1 • Information Technology Equipment – Safety – Part 1: General Requirements •...
  • Page 41: Fcc

    Methods of Measurement The device is marked with a CE marking and can be used throughout the European community. A copy of the CE Declaration of Conformity is available from Siemens Canada Ltd.. For contact information, refer to "Contacting Siemens (Page vii)".
  • Page 42: Ised

    Certification 6.1.5 ISED 6.1.5 ISED This device is declared by Siemens Canada Ltd. to meet the requirements of the following ISED (Innovation Science and Economic Development Canada) standard: • CAN ICES-3 (A)/NMB-3 (A) 6.1.6 This device was designed and manufactured using a certified ISO (International...
  • Page 43: Emc And Environmental Type Tests

    Certification 6.2 EMC and Environmental Type Tests EMC and Environmental Type Tests The RUGGEDCOM M2200F has passed the following Electromagnetic Compatibility (EMC) and environmental tests. EMC Type Tests per IEC 61850-3 Note • In the case of an all fiber port configuration, this product meets all Class 2 requirements.
  • Page 44 DC Power Ports 5 kV   AC Power Ports   Siemens-specified severity levels EMC Immunity Type Tests per IEEE 1613 Note RUGGEDCOM products meet Class 1 requirements for copper Ethernet configurations and Class 2 for fiber Ethernet configurations. Class 1 allows for temporary communication loss, while Class 2 requires error-free and interrupted communications.
  • Page 45 Certification 6.2 EMC and Environmental Type Tests Description Test Levels AC Power Ports 4 kV Earth Ground Ports 4 kV Oscillatory Signal Ports 2.5 kV Common Mode @ 1 MHz DC Power Ports 2.5 kV Common 1 kV differential mode @ 1 MHz AC Power Ports 2.5 kV Common 1 kV differential mode @ 1 MHz...
  • Page 46 Certification 6.2 EMC and Environmental Type Tests Test Description Test Levels MIL-STD-167-1 Vibration Type I (4-33 Hz) MIL-STD-461E Electromagnetic Interference CE101, CE102, CS101, CS114, CS115, CS116, RE101, RE102, RS101, RS103 MIL-STD-1399 Magnetic Field – DC Section 070, Part 1 Magnetic Exposure MIL-STD-810F Low Pressure Altitude Method 500 Series Procedures...
  • Page 47 Certification 6.2 EMC and Environmental Type Tests RUGGEDCOM M2200F Installation Manual, 04/2022, C79000-G8976-1343-09...
  • Page 48 For more information Siemens RUGGEDCOM https://www.siemens.com/ruggedcom Industry Online Support (service and support) https://support.industry.siemens.com Industry Mall https://mall.industry.siemens.com Siemens Canada Ltd. Digital Industries Process Automation 300 Applewood Crescent Concord, Ontario, L4K 4E5 Canada © 2022 Siemens Canada Ltd. Subject to change...