Troubleshooting
7.1 Troubleshooting
If log file upload is disabled, the log files are saved locally. This local space is limited (200 MB). The
files are written and after reaching this limit the oldest files are overwritten.
After the log file upload has been reactivated, previously saved MERS log files are uploaded to
Industrial IoT (max. 200 MB).
JSON Code:
{
"Commands": [
{
"Cmd": "ChangeLogFileUploadConfiguration",
"EnableUpload":
}
]
}
You can set the following command parameters:
Parameter
EnableUpload
Changing log upload by USB command will not be synchronized with the asset's
device configuration on Industrial IoT side.
Perform factory reset
For factory reset a
The network and BoxMgr settings will be reset to their initial state on MindConnect Nano. All
BoxMgr and MERS logging files and temporary files will be then deleted. At the end the
MindConnect device will be restarted automatically.
Offboard the asset and device before factory reset execution and perform the
factory reset. After the execution, the asset and device should be onboarded again.
The factory reset command will be available on MindConnect Nano version 03.01.00.00 b00x or
later.
JSON Code:
{
"Commands": [
{
"Cmd": "DoFactoryReset",
MindConnect Nano
System Manual 7/2023
"true"
Description
true: enable log file upload
false: disable log file upload
ConBox_Commands.json
file can be provided by using the USB stick.