IBM IntelliStation R Pro Hardware Maintenance Manual page 29

Table of Contents

Advertisement

Table 5. NDIS (Windows NT or Windows 2000) driver messages for the Ethernet controller.
Error code (hex)
0x00
Explanation: The driver could not register the specified interrupt. Action: Using the
Configuration/Setup utility, make sure that a PCI interrupt is assigned to your Ethernet card, and
that Ethernet is enabled.
0x01
Explanation: One of the PCI cards did not get the required resources. Action: Using the
Configuration/Setup utility, make sure that a PCI interrupt is assigned to your Ethernet card, and
that Ethernet is enabled.
0x02
Explanation: Bad node address (multicast address). Action: Make sure the locally administered
address is valid, if one is specified. The address can not be a multicast address.
0x03
Explanation: Failed self-test. Action: Make sure a cable is attached to the Ethernet connector. If the
problem persists, call for service.
0x0D
Explanation: Could not allocate enough memory for transmit queues. Action:
1.
From the Windows NT desktop, select Start -> Control Panel -> Networks -> Adapters.
2.
Select your IBM Ethernet adapter from the list.
3.
Select Properties -> Advanced.
4.
Lower the resource values that apply to the transmit queue.
0x0E
Explanation: Could not allocate enough memory for receive queue. Action:
1.
From the Windows NT desktop, select Start -> Control Panel -> Networks -> Adapters.
2.
Select your IBM Ethernet adapter from the list.
3.
Select Properties -> Advanced.
4.
Lower the resource values that apply to the receive queue.
0x0F
Explanation: Could not allocate enough memory for other structures. Action:
1.
From the Windows NT desktop, select Start -> Control Panel -> Networks -> Adapters.
2.
Select your IBM Ethernet adapter from the list.
3.
Select Properties -> Advanced.
4.
Lower the value for the resource named in the message.
0x10
Explanation: Did not find any Ethernet controllers. Action: Using the Configuration/Setup utility,
make sure that Ethernet is enabled.
0x11
Explanation: Multiple Ethernet controllers found, but none matched the required ID. Action:
Using the Configuration/Setup utility, make sure that Ethernet is enabled.
0x13
Explanation: Did not find any Ethernet controllers that matched the required subven/subdev.
Action: Using the Configuration/Setup utility, make sure that Ethernet is enabled.
0x16
Explanation: Single adapter found but multiple instances tried to load. Action: Using the
Configuration/Setup utility, make sure that Ethernet is enabled, and that the slot containing the
IBM Netfinity 10/100 Ethernet Adapter or the IBM 10/100 Etherjet PCI adapter is enabled.
0x17
Explanation: Slot parameter not specified in the registry. Action: Remove the adapter driver and
reinstall it. If the problem persists, call for service.
All other 4-
Action: Call for service.
character
hexadecimal
codes
Ethernet teaming messages:
Description
21
Diagnostics

Advertisement

Table of Contents
loading

This manual is also suitable for:

330 xseries86746851

Table of Contents