Electrical Connection - Blodgett SG2136E Installation Operation & Maintenance

Table of Contents

Advertisement

Available languages

Available languages

Before making any electrical connections to this
unit, check that the power supply is adequate for
the voltage, amperage, and phase requirements
stated on the rating plate.
A wiring diagram accompanies this manual and is
also attached to the rear of the oven.
SG2136G
U.S. and Canadian installations
SG2136G ovens require a 5 amp, 60HZ, 1Φ,
208-240 VAC, 3 wire service consisting of L1, L2
and ground. Use 75_C wire and size to National
Electric or local codes.
Single phase units MUST NOT be connected to the
high leg of a three phase system. The high leg refers
to a potential of 240 volts between one phase and
neutral. The remaining two legs have a potential of
120 volts between each phase and neutral.
General export installations
SG2136G ovens require a 5 amp, 50/60HZ (see
rating plate), 1Φ, 208-240VAC, 3 wire service con-
sisting of L1, neutral (or L2) and ground. Use 75_C
wire and size to National Electric or local codes.
SG2136E 1Φ
L1
L2
Supply
SG2136E Delta Power 3Φ
U.S. and Canadian Installations (or similar)
L1
L2
Supply
L3
208-240
Oven
208 or 240
(typical)
Oven
Figure 18
Installation
SG2136E
U.S. and Canadian installations
SG2136E ovens are available in either 1Φ or 3Φ
options. Single phase models require a 90 amp,
60 HZ, 208-240 VAC (see rating plate) 3 wire ser-
vice consisting of L1, L2 and ground. Three phase
units require a 60 amp, 60 HZ, 208-240 VAC (see
rating plate) 4 wire service consisting of L1, L2, L3,
and ground. Use 75_C wire and size to National
Electric or local codes.
Australia and General Export installations
SG2136E ovens are available in either 1Φ or 3Φ
options. Single phase units require a 90 amp,
50/60 HZ (see rating plate), 208-240 VAC (see rat-
ing plate) 3 wire service consisting of L1, L2 and
ground. Three phase units require a 30 amp,
50/60 HZ (see rating plate), 208-240 VAC (see rat-
ing plate) 4 wire service consisting of L1, L2, L3
and ground. Use 75_C wire and size to National
Electric or local codes.
WARNING!!
Incorrect wiring will result in extensive
damage to electrical components and
possible fire in the control panel.
THE BLODGETT OVEN COMPANY CANNOT AS-
SUME RESPONSIBILITY FOR LOSS OR DAMAGE
SUFFERED AS A RESULT OF IMPROPER INSTAL-
LATION.
Supply
SG2136E Wye Power 3Φ
Australia and General Export Installations
L1
380/400/415
L2
Supply
380/400/415
L3
N
21

Electrical Connection

SG2136G 1Φ
L1
208-240
L2
Oven
220/230/240
380/400/415
Oven