Download Print this page
Endress+Hauser Proline Promass X 500 PROFIBUS PA Operating Instructions Manual

Endress+Hauser Proline Promass X 500 PROFIBUS PA Operating Instructions Manual

Coriolis flowmeter
Hide thumbs Also See for Proline Promass X 500 PROFIBUS PA:

Advertisement

Quick Links

BA01558D/06/EN/02.18
71415081
2018-11-01
Valid as of version
01.01.zz (Device firmware)
Products
Operating Instructions
Proline Promass X 500
PROFIBUS PA
Coriolis flowmeter
Solutions
Services

Advertisement

loading

Summary of Contents for Endress+Hauser Proline Promass X 500 PROFIBUS PA

  • Page 1 Products Solutions Services BA01558D/06/EN/02.18 71415081 2018-11-01 Valid as of version 01.01.zz (Device firmware) Operating Instructions Proline Promass X 500 PROFIBUS PA Coriolis flowmeter...
  • Page 2 • The manufacturer reserves the right to modify technical data without prior notice. Your Endress+Hauser Sales Center will supply you with current information and updates to these instructions. Endress+Hauser...
  • Page 3 Proline Promass X 500 PROFIBUS PA Table of contents Table of contents About this document ....6 Installation ..... . . 22 Document function .
  • Page 4 Table of contents Proline Promass X 500 PROFIBUS PA 8.2.2 Operating philosophy ... . 62 10.2 Switching on the measuring device ..100 Access to the operating menu via the local 10.3 Connecting via FieldCare .
  • Page 5 13.2 Measuring and test equipment ... 240 13.3 Endress+Hauser services ....240 Repairs ......241 14.1 General notes .
  • Page 6 About this document Proline Promass X 500 PROFIBUS PA About this document Document function These Operating Instructions contain all the information that is required in various phases of the life cycle of the device: from product identification, incoming acceptance and storage, to mounting, connection, operation and commissioning through to troubleshooting, maintenance and disposal.
  • Page 7 Proline Promass X 500 PROFIBUS PA About this document Symbol Meaning Light emitting diode is on. Light emitting diode is flashing. 1.2.4 Tool symbols Symbol Meaning Torx screwdriver Phillips head screwdriver Open-ended wrench 1.2.5 Symbols for certain types of information...
  • Page 8 • W@M Device Viewer (www.endress.com/deviceviewer): Enter the serial number from nameplate • Endress+Hauser Operations App: Enter the serial number from the nameplate or scan the 2D matrix code (QR code) on the nameplate Detailed list of the individual documents along with the documentation code →...
  • Page 9 Proline Promass X 500 PROFIBUS PA Basic safety instructions Basic safety instructions Requirements for the personnel The personnel for installation, commissioning, diagnostics and maintenance must fulfill the following requirements: ‣ Trained, qualified specialists must have a relevant qualification for this specific function and task.
  • Page 10 Verification for borderline cases: ‣ For special fluids and fluids for cleaning, Endress+Hauser is glad to provide assistance in verifying the corrosion resistance of fluid-wetted materials, but does not accept any warranty or liability as minute changes in the temperature, concentration or level of contamination in the process can alter the corrosion resistance properties.
  • Page 11 It meets general safety standards and legal requirements. It also complies with the EU directives listed in the device-specific EU Declaration of Conformity. Endress+Hauser confirms this by affixing the CE mark to the device.
  • Page 12 Basic safety instructions Proline Promass X 500 PROFIBUS PA 2.7.2 Protecting access via a password Different passwords are available to protect write access to the device parameters or access to the device via the WLAN interface. • User-specific access code Protect write access to the device parameters via the local display, Web browser or operating tool (e.g.
  • Page 13 Proline Promass X 500 PROFIBUS PA Basic safety instructions The device and status information can be hidden on the login page. This prevents unauthorized access to the information. For detailed information on device parameters, see: The "Description of Device Parameters" document →  273.
  • Page 14 Product description Proline Promass X 500 PROFIBUS PA Product description The measuring system consists of a transmitter and a sensor. The transmitter and sensor are mounted in physically separate locations. They are interconnected by connecting cables. Product design Two versions of the transmitter are available.
  • Page 15 Proline Promass X 500 PROFIBUS PA Product description 3.1.2 Proline 500 Signal transmission: analog Order code for "Integrated ISEM electronics", option B "Transmitter" For use in applications required to meet special requirements due to ambient or operating conditions. As the electronics are located in the transmitter, the device is ideal in the event of: •...
  • Page 16 Technical Documentation present? • If one of the conditions is not satisfied, contact your Endress+Hauser Sales Center. • Depending on the device version, the CD-ROM might not be part of the delivery! The Technical Documentation is available via the Internet or via the Endress+Hauser Operations App, see the "Product identification"...
  • Page 17  8 sections • The W@M Device Viewer: enter the serial number from the nameplate (www.endress.com/deviceviewer) • The Endress+Hauser Operations App: Enter the serial number from the nameplate or scan the 2-D matrix code (QR code) on the nameplate. 4.2.1 Transmitter nameplate Proline 500 –...
  • Page 18 Incoming acceptance and product identification Proline Promass X 500 PROFIBUS PA Proline 500 3 4 5 Order code: Ser. no.: Ext. ord. cd.: Date: A0029192  4 Example of a transmitter nameplate Manufacturing location Name of the transmitter Order code Serial number (ser.
  • Page 19 Proline Promass X 500 PROFIBUS PA Incoming acceptance and product identification 4.2.2 Sensor nameplate Order code: Ser. no.: Ext. ord. cd.: Date: A0029199  5 Example of a sensor nameplate Name of the sensor Manufacturing location Order code Serial number (ser. no.) Extended order code (Ext.
  • Page 20 Incoming acceptance and product identification Proline Promass X 500 PROFIBUS PA 4.2.3 Symbols on measuring device Symbol Meaning WARNING! This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in serious or fatal injury. Reference to documentation Refers to the corresponding device documentation.
  • Page 21 Proline Promass X 500 PROFIBUS PA Storage and transport Storage and transport Storage conditions Observe the following notes for storage: ‣ Store in the original packaging to ensure protection from shock. ‣ Do not remove protective covers or protective caps installed on process connections.
  • Page 22 Installation Proline Promass X 500 PROFIBUS PA 5.2.2 Measuring devices with lifting lugs CAUTION Special transportation instructions for devices with lifting lugs ‣ Only use the lifting lugs fitted on the device or flanges to transport the device. ‣ The device must always be secured at two lifting lugs at least.
  • Page 23 Proline Promass X 500 PROFIBUS PA Installation To prevent measuring errors arising from accumulation of gas bubbles in the measuring tube, avoid the following mounting locations in the pipe: • Highest point of a pipeline. • Directly upstream of a free pipe outlet in a down pipe.
  • Page 24 Installation Proline Promass X 500 PROFIBUS PA Orientation Recommendation Horizontal orientation, transmitter at bottom →  7,  24 A0015590 Horizontal orientation, transmitter at →  7,  24 side A0015592 This orientation is recommended to ensure self-draining. Applications with low process temperatures may decrease the ambient temperature. To maintain the minimum ambient temperature for the transmitter, this orientation is recommended.
  • Page 25 If operating outdoors: Avoid direct sunlight, particularly in warm climatic regions. You can order a weather protection cover from Endress+Hauser. →  243. System pressure It is important that cavitation does not occur, or that gases entrained in the liquids do not outgas.
  • Page 26 Installation Proline Promass X 500 PROFIBUS PA NOTICE Electronics overheating on account of thermal insulation! ‣ Recommended orientation: horizontal orientation, sensor connection housing pointing downwards. ‣ Do not insulate the sensor connection housing. ‣ Maximum permissible temperature at the lower end of the sensor connection housing: 80 °C (176 °F)
  • Page 27 Proline Promass X 500 PROFIBUS PA Installation The sheet must have the following properties: • Relative magnetic permeability µr ≥ 300 • Plate thickness d ≥ 0.35 mm (d ≥ 0.014 in) Vibrations The high oscillation frequency of the measuring tubes ensures that the correct operation of the measuring system is not influenced by plant vibrations.
  • Page 28 Installation Proline Promass X 500 PROFIBUS PA RUPTURE DISK A0029944 Rupture disk label Rupture disk with 1/2" NPT internal thread with 1" width across flat Transport protection Zero point adjustment All measuring devices are calibrated in accordance with state-of-the-art technology.
  • Page 29 Proline Promass X 500 PROFIBUS PA Installation 280 (11.0) 255 (10.0) 146 (5.75) 134 (5.3) 12 (0.47) 30 (1.18) A0029553  10 Weather protection cover for Proline 500 Cover locking: Proline 500 NOTICE Order code for "Transmitter housing", option L "Cast, stainless": The covers of the transmitter housing are provided with a borehole to lock the cover.
  • Page 30 Installation Proline Promass X 500 PROFIBUS PA For wall mounting: Drill with drill bit ⌀ 6.0 mm For sensor For flanges and other process connections: Corresponding mounting tools 6.2.2 Preparing the measuring device 1. Remove all remaining transport packaging. 2. Remove any protective covers or protective caps present from the sensor.
  • Page 31 Proline Promass X 500 PROFIBUS PA Installation Post mounting WARNING Excessive tightening torque applied to the fixing screws! Risk of damaging the plastic transmitter. ‣ Tighten the fixing screws as per the tightening torque: 2 Nm (1.5 lbf ft) ø...
  • Page 32 Installation Proline Promass X 500 PROFIBUS PA 2. Insert wall plugs into the drilled holes. 3. Screw in the securing screws slightly at first. 4. Fit the transmitter housing over the securing screws and mount in place. 5. Tighten the securing screws.
  • Page 33 Proline Promass X 500 PROFIBUS PA Installation Post mounting WARNING Order code for "Transmitter housing", option L "Cast, stainless": cast transmitters are very heavy. They are unstable if they are not mounted on a secure, fixed post. ‣ Only mount the transmitter on a secure, fixed post on a stable surface.
  • Page 34 Installation Proline Promass X 500 PROFIBUS PA 7. Depending on the device version: Attach the securing clamp of the connection compartment cover. 6.2.7 Turning the display module: Proline 500 The display module can be turned to optimize display readability and operability.
  • Page 35 Proline Promass X 500 PROFIBUS PA Electrical connection Electrical connection NOTICE The measuring device does not have an internal circuit breaker. ‣ For this reason, assign the measuring device a switch or power-circuit breaker so that the power supply line can be easily disconnected from the mains.
  • Page 36 Electrical connection Proline Promass X 500 PROFIBUS PA Pulse/frequency/switch output Standard installation cable is sufficient. Relay output Standard installation cable is sufficient. Current input 0/4 to 20 mA Standard installation cable is sufficient. Status input Standard installation cable is sufficient.
  • Page 37 Proline Promass X 500 PROFIBUS PA Electrical connection A: Connecting cable between sensor and transmitter: Proline 500 – digital Standard cable A standard cable with the following specifications can be used as the connecting cable. Design 4 cores (2 pairs); uninsulated stranded CU wires; pair-stranded with common...
  • Page 38 Electrical connection Proline Promass X 500 PROFIBUS PA Cross-section Cable length [max.] Termination 2 x 2 x 0.50 mm 50 m (165 ft) 2 x 2 x 0.50 mm (AWG 20) (AWG 20) BN WT YE GN • +, – = 0.5 mm •...
  • Page 39 Proline Promass X 500 PROFIBUS PA Electrical connection C: Connecting cable between sensor and transmitter: Proline 500 Standard cable 6 × 0.38 mm PVC cable with common shield and individually shielded cores Conductor resistance ≤50 Ω/km (0.015 Ω/ft) Capacitance: core/shield ≤420 pF/m (128 pF/ft)
  • Page 40 Electrical connection Proline Promass X 500 PROFIBUS PA 7.1.5 Pin assignment of device plug Assignment Coding Plug/socket PROFIBUS PA + Plug Grounding PROFIBUS PA – Not assigned 7.1.6 Shielding and grounding Optimal electromagnetic compatibility (EMC) of the fieldbus system can be guaranteed only if the system components and, in particular, the lines are shielded and the shield forms as complete a cover as possible.
  • Page 41 Proline Promass X 500 PROFIBUS PA Electrical connection A0028768  15 Connection example for PROFIBUS PA Control system (e.g. PLC) PROFIBUS PA segment coupler Cable shield: the cable shield must be grounded at both ends to comply with EMC requirements; observe cable...
  • Page 42 Electrical connection Proline Promass X 500 PROFIBUS PA Connecting the measuring device: Proline 500 - digital NOTICE Limitation of electrical safety due to incorrect connection! ‣ Have electrical connection work carried out by appropriately trained specialists only. ‣ Observe applicable federal/national installation codes and regulations.
  • Page 43 Proline Promass X 500 PROFIBUS PA Electrical connection Connecting the sensor connection housing via terminals For the device version with the order code for "Sensor connection housing": Option L "Cast, stainless" 10 (0.4) 3 mm TX 20 TX 20 22 mm...
  • Page 44 Electrical connection Proline Promass X 500 PROFIBUS PA Connecting the connecting cable to the transmitter TX 20 TX 20 10 (0.4) 22 mm 24 mm A0029597 1. Loosen the 4 fixing screws on the housing cover. 2. Open the housing cover.
  • Page 45 Proline Promass X 500 PROFIBUS PA Electrical connection 7.2.2 Connecting the signal cable and the supply voltage cable A0028200 Terminal connection for supply voltage Terminal connection for signal transmission, input/output Terminal connection for signal transmission, input/output Terminal connection for connecting cable between sensor and transmitter Terminal connection for signal transmission, input/output;...
  • Page 46 Electrical connection Proline Promass X 500 PROFIBUS PA WARNING Housing degree of protection may be voided due to insufficient sealing of the housing. ‣ Screw in the screw without using any lubricant. WARNING Excessive tightening torque applied to the fixing screws! Risk of damaging the plastic transmitter.
  • Page 47 Proline Promass X 500 PROFIBUS PA Electrical connection Connecting the measuring device: Proline 500 NOTICE Limitation of electrical safety due to incorrect connection! ‣ Have electrical connection work carried out by appropriately trained specialists only. ‣ Observe applicable federal/national installation codes and regulations.
  • Page 48 Electrical connection Proline Promass X 500 PROFIBUS PA Connecting the sensor connection housing via terminals For the device version with the order code for "Housing": Option L "Cast, stainless" 10 (0.4) 3 mm 22 mm 24 mm A0029612 1. Loosen the securing clamp of the housing cover.
  • Page 49 Proline Promass X 500 PROFIBUS PA Electrical connection Connecting the connecting cable to the transmitter 10 (0.4) 3 mm 22 mm 24 mm A0029592 1. Loosen the securing clamp of the connection compartment cover. 2. Unscrew the connection compartment cover.
  • Page 50 Electrical connection Proline Promass X 500 PROFIBUS PA 7.3.2 Connecting the signal cable and the supply voltage cable A0026781 Terminal connection for supply voltage Terminal connection for signal transmission, input/output Terminal connection for signal transmission, input/output or terminal connection for network connection via...
  • Page 51 Proline Promass X 500 PROFIBUS PA Electrical connection 10 (0.4) mm (in) – A0029815 7. Push the cable through the cable entry . To ensure tight sealing, do not remove the sealing ring from the cable entry. 8. Strip the cable and cable ends. In the case of stranded cables, also fit ferrules.
  • Page 52 Electrical connection Proline Promass X 500 PROFIBUS PA Removing a cable 3 (0.12) A0029598  17 Engineering unit mm (in) 1. To remove a cable from the terminal, use a flat-blade screwdriver to push the slot between the two terminal holes 2.
  • Page 53 Proline Promass X 500 PROFIBUS PA Electrical connection Special connection instructions 7.5.1 Connection examples PROFIBUS PA A0028768  18 Connection example for PROFIBUS PA Control system (e.g. PLC) PROFIBUS PA segment coupler Cable shield: the cable shield must be grounded at both ends to comply with EMC requirements; observe cable...
  • Page 54 Electrical connection Proline Promass X 500 PROFIBUS PA 4...20 mA A0028759  20 Connection example for 4-20 mA current output (passive) Automation system with current input (e.g. PLC) Active barrier for power supply (e.g. RN221N) Analog display unit: observe maximum load...
  • Page 55 Proline Promass X 500 PROFIBUS PA Electrical connection Relay output A0028760  23 Connection example for relay output (passive) Automation system with relay input (e.g. PLC) Power supply Transmitter: Observe input values →  251 Current input A0028915  24...
  • Page 56 Electrical connection Proline Promass X 500 PROFIBUS PA Hardware settings 7.6.1 Setting the device address The address must always be configured for a PROFIBUS DP/PA device. The valid address range is between 1 and 126. In a PROFIBUS DP/PA network, each address can only be assigned once.
  • Page 57 Proline Promass X 500 PROFIBUS PA Electrical connection Software addressing ‣ To switch addressing from hardware addressing to software addressing: set DIP switch No. 4 to Off.  The device address configured in the Device address parameter (→  108) takes effect after 10 seconds.
  • Page 58 Electrical connection Proline Promass X 500 PROFIBUS PA A0034500 1. Loosen the 4 fixing screws on the housing cover. 2. Open the housing cover. 3. Fold open the terminal cover. 4. Set DIP switch No. 2 on the I/O electronics module from OFF → ON.
  • Page 59 Proline Promass X 500 PROFIBUS PA Electrical connection Ensuring the degree of protection The measuring device fulfills all the requirements for the IP66/67 degree of protection, Type 4X enclosure. To guarantee IP66/67 degree of protection, Type 4X enclosure, carry out the following steps after the electrical connection: 1.
  • Page 60 Operation options Proline Promass X 500 PROFIBUS PA Operation options Overview of operation options A0034513 Local operation via display module Computer with Web browser (e.g. Internet Explorer) or with operating tool (e.g. FieldCare, DeviceCare, AMS Device Manager, SIMATIC PDM) Field Xpert SFX350 or SFX370...
  • Page 61 Proline Promass X 500 PROFIBUS PA Operation options Structure and function of the operating menu 8.2.1 Structure of the operating menu For an overview of the operating menu for experts: "Description of Device Parameters" document supplied with the device→  273...
  • Page 62 Operation options Proline Promass X 500 PROFIBUS PA 8.2.2 Operating philosophy The individual parts of the operating menu are assigned to certain user roles (operator, maintenance etc.). Each user role contains typical tasks within the device lifecycle. For custody transfer, once the device has been put into circulation or sealed, its operation is restricted.
  • Page 63 Proline Promass X 500 PROFIBUS PA Operation options Menu/parameter User role and tasks Content/meaning Expert function-oriented Tasks that require detailed Contains all the parameters of the device and makes it possible to access these knowledge of the function of the parameters directly using an access code.
  • Page 64 Operation options Proline Promass X 500 PROFIBUS PA Status area The following symbols appear in the status area of the operational display at the top right: • Status signals→  173 – F: Failure – C: Function check – S: Out of specification –...
  • Page 65 Proline Promass X 500 PROFIBUS PA Operation options 8.3.2 Navigation view In the submenu In the wizard /../Operation 0091-1 /../Select medium Access stat.disp Select medium Operator Liquid Locking status Display A0013993-EN A0013995-EN Navigation view Navigation path to current position Status area Display area for navigation Operating elements →...
  • Page 66 Operation options Proline Promass X 500 PROFIBUS PA Display area Menus Symbol Meaning Operation Appears: • In the menu next to the "Operation" selection • At the left in the navigation path in the Operation menu Setup Appears: • In the menu next to the "Setup" selection •...
  • Page 67 Proline Promass X 500 PROFIBUS PA Operation options 8.3.3 Editing view Numeric editor +0.000 Xx – A0034250  27 For entering values in parameters (e.g. limit values) Entry display area Input screen Confirm, delete or reject entry Operating elements Text editor...
  • Page 68 Operation options Proline Promass X 500 PROFIBUS PA Operating key(s) Meaning Enter key • Press the key briefly: confirm your selection. • Press the key for 2 s: confirm the entry. Escape key combination (press keys simultaneously) Close the editing view without accepting the changes.
  • Page 69 Proline Promass X 500 PROFIBUS PA Operation options 8.3.4 Operating elements Operating key(s) Meaning Minus key In a menu, submenu Moves the selection bar upwards in a picklist. With a Wizard Confirms the parameter value and goes to the previous parameter.
  • Page 70 Operation options Proline Promass X 500 PROFIBUS PA Calling up and closing the context menu The user is in the operational display. 1. Press the  and  keys for longer than 3 seconds.  The context menu opens. XXXXXXXXXX Setup Conf.backup...
  • Page 71 Proline Promass X 500 PROFIBUS PA Operation options 8.3.6 Navigating and selecting from list Different operating elements are used to navigate through the operating menu. The navigation path is displayed on the left in the header. Icons are displayed in front of the individual menus.
  • Page 72 Operation options Proline Promass X 500 PROFIBUS PA The direct access code consists of a 5-digit number (at maximum) and the channel number, which identifies the channel of a process variable: e.g. 00914-2. In the navigation view, this appears on the right-hand side in the header of the selected parameter.
  • Page 73 Proline Promass X 500 PROFIBUS PA Operation options Ent. access code Invalid or out of range input value Min:0 Max:9999 A0014049-EN For a description of the editing view - consisting of the text editor and numeric editor - with symbols →  67, for a description of the operating elements →  69 8.3.10...
  • Page 74 Operation options Proline Promass X 500 PROFIBUS PA 2. Enter the access code.  The -symbol in front of the parameters disappears; all previously write- protected parameters are now re-enabled. 8.3.12 Enabling and disabling the keypad lock The keypad lock makes it possible to block access to the entire operating menu via local operation.
  • Page 75 Proline Promass X 500 PROFIBUS PA Operation options 8.4.2 Prerequisites Computer hardware Hardware Interface CDI-RJ45 WLAN Interface The computer must have an RJ45 The operating unit must have a interface. WLAN interface. Connection Standard Ethernet cable with RJ45 Connection via Wireless LAN.
  • Page 76 Operation options Proline Promass X 500 PROFIBUS PA Measuring device: Via CDI-RJ45 service interface Device CDI-RJ45 service interface Measuring device The measuring device has an RJ45 interface. Web server Web server must be enabled; factory setting: ON  For information on enabling the Web server →  80...
  • Page 77 Proline Promass X 500 PROFIBUS PA Operation options IP address 192.168.1.XXX; for XXX all numerical sequences except: 0, 212 and 255 → e.g. 192.168.1.213 Subnet mask 255.255.255.0 Default gateway 192.168.1.212 or leave cells empty Via WLAN interface Configuring the Internet protocol of the mobile terminal NOTICE If the WLAN connection is lost during the configuration, settings made may be lost.
  • Page 78 Operation options Proline Promass X 500 PROFIBUS PA 2. Enter the IP address of the Web server in the address line of the Web browser: 192.168.1.212  The login page appears. 2 3 4 A0029417 Picture of device Device name...
  • Page 79 Proline Promass X 500 PROFIBUS PA Operation options 8.4.5 User interface A0029418 Function row Local display language Navigation area Header The following information appears in the header: • Device name • Device tag • Device status with status signal →  176 •...
  • Page 80 Operation options Proline Promass X 500 PROFIBUS PA Navigation area If a function is selected in the function bar, the submenus of the function open in the navigation area. The user can now navigate through the menu structure. Working area...
  • Page 81 Proline Promass X 500 PROFIBUS PA Operation options 3. If no longer needed: Reset modified properties of the Internet protocol (TCP/IP) →  76. Access to the operating menu via the operating tool The structure of the operating menu in the operating tools is the same as for operation via the local display.
  • Page 82 Operation options Proline Promass X 500 PROFIBUS PA Proline 500 – digital transmitter open press A0029163  31 Connection via service interface (CDI-RJ45) Computer with Web browser (e.g. Microsoft Internet Explorer, Microsoft Edge) for accessing the integrated device Web server or with "FieldCare", "DeviceCare" operating tool with COM DTM "CDI Communication TCP/IP"...
  • Page 83 Proline Promass X 500 PROFIBUS PA Operation options A0034569 Transmitter with integrated WLAN antenna Transmitter with external WLAN antenna LED lit constantly: WLAN reception is enabled on measuring device LED flashing: WLAN connection established between operating unit and measuring device Computer with WLAN interface and Web browser (e.g.
  • Page 84 FieldCare Function scope FDT-based plant asset management tool from Endress+Hauser. It can configure all smart field devices in a system and helps you manage them. By using the status information, it is also a simple but effective way of checking their status and condition.
  • Page 85 Proline Promass X 500 PROFIBUS PA Operation options Establishing a connection 1. Start FieldCare and launch the project. 2. In the network: Add a device.  The Add device window opens. 3. Select the CDI Communication TCP/IP option from the list and press OK to confirm.
  • Page 86 DeviceCare Function scope Tool to connect and configure Endress+Hauser field devices. The fastest way to configure Endress+Hauser field devices is with the dedicated "DeviceCare" tool. Together with the device type managers (DTMs) it presents a convenient, comprehensive solution. For details, see Innovation Brochure IN01047S Source for device description files See information →...
  • Page 87 Proline Promass X 500 PROFIBUS PA System integration System integration Overview of device description files 9.1.1 Current version data for the device Firmware version 01.01.zz • On the title page of the Operating instructions • On the transmitter nameplate • Firmware version Diagnostics →...
  • Page 88 System integration Proline Promass X 500 PROFIBUS PA 9.2.1 Manufacturer-specific GSD This GSD guarantees the unrestricted functionality of the measuring device. Device-specific process parameters and functions are therefore available. Manufacturer-specific GSD ID number File name PROFIBUS PA 0x156D EH3x156D.gsd Use manufacturer-specific GSD Assignment is performed in the Ident number selector parameter via the Manufacturer option.
  • Page 89 Proline Promass X 500 PROFIBUS PA System integration Compatibility with earlier model If the device is replaced, the measuring device Promass 500 supports the compatibility of the cyclic data with previous models. It is not necessary to adjust the engineering parameters of the PROFIBUS network with the Promass 500 GSD file.
  • Page 90 System integration Proline Promass X 500 PROFIBUS PA 2. Set the device address: The same device address that was set for the Promass 80 or Promass 83 PROFIBUS PA must be used. 3. Connect the measuring device Promass 500 PROFIBUS PA.
  • Page 91 Proline Promass X 500 PROFIBUS PA System integration Previous model: Promass 83 PROFIBUS PA Control variable Function Support 0 → 2 Positive zero return: ON 0 → 3 Positive zero return: OFF 0 → 4 Zero point adjustment: START 0 → 8...
  • Page 92 System integration Proline Promass X 500 PROFIBUS PA Cyclic data transmission Cyclic data transmission when using the device master file (GSD). 9.5.1 Block model The block model shows which input and output data the measuring device makes available for cyclic data exchange. Cyclic data exchange takes place with a PROFIBUS master (Class 1), e.g.
  • Page 93 Proline Promass X 500 PROFIBUS PA System integration AI module (Analog Input) Transmit an input variable from the measuring device to the PROFIBUS master (Class 1). The selected input variable, along with the status, is cyclically transmitted to the PROFIBUS Master (Class 1) via the AI module. The input variable is depicted in the first four bytes in the form of a floating point number as per the IEEE 754 standard.
  • Page 94 System integration Proline Promass X 500 PROFIBUS PA Input variable Alternative GSV flow NSV flow Alternative NSV flow S&W volume flow Water cut percentage Oil density Water density Oil mass flow Water mass flow Oil volume flow Water volume flow...
  • Page 95 Proline Promass X 500 PROFIBUS PA System integration Selection: totalizer value Input variable Mass flow Volume flow Corrected volume flow Target fluid mass flow Carrier mass flow Only available with the "Concentration" application package Factory setting Function block Factory setting: TOTAL...
  • Page 96 System integration Proline Promass X 500 PROFIBUS PA Input data of TOTAL Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Measured value: floating point number (IEEE 754) Status SETTOT_MODETOT_TOTAL module The module combination consists of the SETTOT, MODETOT and TOTAL functions: •...
  • Page 97 Proline Promass X 500 PROFIBUS PA System integration Assigned compensation values A compensation value is permanently assigned to the individual Analog Output blocks. Function block Compensation value AO 1 External pressure AO 2 External temperature AO 3 External reference density AO 4 External S&W percentage...
  • Page 98 System integration Proline Promass X 500 PROFIBUS PA Data structure Input data of Discrete Input Byte 1 Byte 2 Discrete Status DO module (Discrete Output) Transmit discrete output values from the PROFIBUS master (Class 1) to the measuring device. Discrete output values are used by the PROFIBUS master (Class 1) to enable and disable device functions.
  • Page 99 Proline Promass X 500 PROFIBUS PA System integration Assignment of medium type: function block DO 5 Original wort % mass / % volume Coef Set No. 1 Coef Set No. 2 Coef Set No. 3 Hydrochloric acid Sulfuric acid Data structure...
  • Page 100 Commissioning Proline Promass X 500 PROFIBUS PA Commissioning 10.1 Function check Before commissioning the measuring device: ‣ Make sure that the post-installation and post-connection checks have been performed. • "Post-installation check" checklist→  34 • "Post-connection check" checklist →  59 10.2...
  • Page 101 Proline Promass X 500 PROFIBUS PA Commissioning X X X X X X X 20.50 Main menu 0104-1 Display language English Operation Setup Display language 0104-1 English à Deutsch Español Français Display language 0104-1 à English Deutsch Español Français Hauptmenü...
  • Page 102 Commissioning Proline Promass X 500 PROFIBUS PA Navigation "Setup" menu  Setup →  103 Device tag ‣ →  103 System units ‣ Medium selection →  106 ‣ Communication →  107 ‣ Analog inputs →  109 ‣...
  • Page 103 Proline Promass X 500 PROFIBUS PA Commissioning XXXXXXXXX A0029422  35 Header of the operational display with tag name Tag name Enter the tag name in the "FieldCare" operating tool →  85 Navigation "Setup" menu → Device tag Parameter overview with brief description...
  • Page 104 Commissioning Proline Promass X 500 PROFIBUS PA Temperature unit →  105 Pressure unit →  105 Parameter overview with brief description Parameter Description Selection Factory setting Mass flow unit Select mass flow unit. Unit choose list Country-specific: • kg/h Result •...
  • Page 105 Proline Promass X 500 PROFIBUS PA Commissioning Parameter Description Selection Factory setting Temperature unit Select temperature unit. Unit choose list Country-specific: • °C Result • °F The selected unit applies for: • Electronic temperature parameter (6053) • Maximum value parameter (6051) •...
  • Page 106 Commissioning Proline Promass X 500 PROFIBUS PA 10.6.3 Selecting and setting the medium The Select medium wizard submenu contains parameters that must be configured in order to select and set the medium. Navigation "Setup" menu → Select medium ‣ Medium selection →...
  • Page 107 Proline Promass X 500 PROFIBUS PA Commissioning Parameter overview with brief description Parameter Prerequisite Description Selection / User Factory setting entry / User interface Select medium – Select medium type. • Liquid Liquid • Gas Select gas type The Gas option is selected in Select measured gas type.
  • Page 108 Commissioning Proline Promass X 500 PROFIBUS PA Navigation "Setup" menu → Communication ‣ Communication →  108 Device address Parameter overview with brief description Parameter Description User entry Factory setting Device address Enter device address. 0 to 126 Endress+Hauser...
  • Page 109 Proline Promass X 500 PROFIBUS PA Commissioning 10.6.5 Configuring the analog inputs The Analog inputs submenu guides the user systematically to the individual Analog input 1 to n submenu. From here you get to the parameters of the individual analog input.
  • Page 110 Commissioning Proline Promass X 500 PROFIBUS PA Parameter overview with brief description Parameter Prerequisite Description Selection / User Factory setting entry Channel – Select the process variable. • Mass flow Mass flow • Volume flow • Corrected volume flow • Density • Reference density •...
  • Page 111 Proline Promass X 500 PROFIBUS PA Commissioning Parameter Prerequisite Description Selection / User Factory setting entry Fail safe type – Select the failure mode. • Fail-safe value • Fallback value • Off Fail-safe value In Fail safe type parameter, Specify the values to be output...
  • Page 112 Commissioning Proline Promass X 500 PROFIBUS PA 10.6.7 Configuring the current input The "Current input" wizard guides the user systematically through all the parameters that have to be set for configuring the current input. Navigation "Setup" menu → Current input ‣...
  • Page 113 Proline Promass X 500 PROFIBUS PA Commissioning 10.6.8 Configuring the status input The Status input submenu guides the user systematically through all the parameters that have to be set for configuring the status input. Navigation "Setup" menu → Status input ‣...
  • Page 114 Commissioning Proline Promass X 500 PROFIBUS PA Signal mode →  114 Assign current output 1 to n →  115 Current span →  115 0/4 mA value →  116 →  116 20 mA value Fixed current →...
  • Page 115 Proline Promass X 500 PROFIBUS PA Commissioning Parameter Prerequisite Description User interface /  Factory setting Selection / User entry Assign current output 1 to n – Select process variable for • Off Mass flow current output. • Mass flow • Volume flow • Corrected volume flow •...
  • Page 116 Commissioning Proline Promass X 500 PROFIBUS PA Parameter Prerequisite Description User interface /  Factory setting Selection / User entry 0/4 mA value One of the following options is Enter 4 mA value. Signed floating-point Country-specific: selected in the Current span number • 0 kg/h parameter (→...
  • Page 117 Proline Promass X 500 PROFIBUS PA Commissioning 10.6.10 Configuring the pulse/frequency/switch output The Pulse/frequency/switch output wizard guides you systematically through all the parameters that can be set for configuring the selected output type. Navigation "Setup" menu → Advanced setup → Pulse/frequency/switch output ‣...
  • Page 118 Commissioning Proline Promass X 500 PROFIBUS PA Parameter overview with brief description Parameter Prerequisite Description Selection / User Factory setting interface / User entry Operating mode – Define the output as a pulse, • Pulse Pulse frequency or switch output. • Frequency • Switch Terminal number –...
  • Page 119 Proline Promass X 500 PROFIBUS PA Commissioning Parameter Prerequisite Description Selection / User Factory setting interface / User entry Failure mode The Pulse option is selected in Define output behavior in • Actual value No pulses the Operating mode alarm condition. • No pulses parameter (→...
  • Page 120 Commissioning Proline Promass X 500 PROFIBUS PA Parameter overview with brief description Parameter Prerequisite Description Selection / User Factory setting interface / User entry Operating mode – Define the output as a pulse, • Pulse Pulse frequency or switch output. • Frequency • Switch Terminal number –...
  • Page 121 Proline Promass X 500 PROFIBUS PA Commissioning Parameter Prerequisite Description Selection / User Factory setting interface / User entry Assign frequency output The Frequency option is Select process variable for • Off selected in the Operating frequency output. • Mass flow mode parameter (→  117) •...
  • Page 122 Commissioning Proline Promass X 500 PROFIBUS PA Parameter Prerequisite Description Selection / User Factory setting interface / User entry Maximum frequency value The Frequency option is Enter maximum frequency. 0.0 to 10 000.0 Hz 10 000.0 Hz selected in the Operating mode parameter (→  117)
  • Page 123 Proline Promass X 500 PROFIBUS PA Commissioning Configuring the switch output Navigation "Setup" menu → Pulse/frequency/switch output ‣ Pulse/frequency/switch output 1 to n Operating mode →  123 Terminal number →  123 Signal mode →  123 →  124...
  • Page 124 Commissioning Proline Promass X 500 PROFIBUS PA Parameter Prerequisite Description Selection / User Factory setting interface / User entry Switch output function The Switch option is selected Select function for switch • Off in the Operating mode output. • On parameter. • Diagnostic behavior •...
  • Page 125 Proline Promass X 500 PROFIBUS PA Commissioning Parameter Prerequisite Description Selection / User Factory setting interface / User entry Assign flow direction check • The Switch option is Select process variable for flow • Off Mass flow selected in the Operating direction monitoring. • Volume flow mode parameter.
  • Page 126 Commissioning Proline Promass X 500 PROFIBUS PA Assign flow direction check →  126 Assign limit →  127 Assign diagnostic behavior →  127 Assign status →  127 →  127 Switch-off value Switch-on value →  127 Failure mode →...
  • Page 127 Proline Promass X 500 PROFIBUS PA Commissioning Parameter Prerequisite Description Selection / User Factory setting interface / User entry Assign limit The Limit option is selected in Select process variable for limit • Mass flow Mass flow the Relay output function function. • Volume flow parameter parameter.
  • Page 128 Commissioning Proline Promass X 500 PROFIBUS PA Parameter Prerequisite Description Selection / User Factory setting interface / User entry Switch-on delay In the Relay output function Define delay for the switch-on 0.0 to 100.0 s 0.0 s parameter, the Limit option is of status output.
  • Page 129 Proline Promass X 500 PROFIBUS PA Commissioning Parameter overview with brief description Parameter Prerequisite Description Selection / User Factory setting entry Format display A local display is provided. Select how measured values • 1 value, max. size 1 value, max. size are shown on the display.
  • Page 130 Commissioning Proline Promass X 500 PROFIBUS PA Parameter Prerequisite Description Selection / User Factory setting entry Value 1 display A local display is provided. Select the measured value that • Mass flow Mass flow is shown on the local display. • Volume flow •...
  • Page 131 Proline Promass X 500 PROFIBUS PA Commissioning Parameter Prerequisite Description Selection / User Factory setting entry 0% bargraph value 1 A local display is provided. Enter 0% value for bar graph Signed floating-point Country-specific: display. number • 0 kg/h • 0 lb/min 100% bargraph value 1 A local display is provided.
  • Page 132 Commissioning Proline Promass X 500 PROFIBUS PA 10.6.13 Configuring the low flow cut off The Low flow cut off wizard systematically guides the user through all the parameters that must be set to configure low flow cut off. Navigation "Setup" menu → Low flow cut off ‣...
  • Page 133 Proline Promass X 500 PROFIBUS PA Commissioning 10.6.14 Configuring the partial filled pipe detection The Partial filled pipe detection wizard guides you systematically through all parameters that have to be set for configuring the monitoring of the pipe filling. Navigation "Setup"...
  • Page 134 Commissioning Proline Promass X 500 PROFIBUS PA 10.7 Advanced settings The Advanced setup submenu together with its submenus contains parameters for specific settings. Navigation to the "Advanced setup" submenu X X X X X X X 20.50 0104-1 Main menu...
  • Page 135 Proline Promass X 500 PROFIBUS PA Commissioning ‣ WLAN settings →  143 ‣ Concentration ‣ Heartbeat setup ‣ Configuration backup →  144 ‣ →  146 Administration 10.7.1 Calculated values The Calculated values submenu contains parameters for calculating the corrected volume flow.
  • Page 136 Commissioning Proline Promass X 500 PROFIBUS PA Parameter Prerequisite Description Selection / User Factory setting interface / User entry Fixed reference density The Fixed reference density Enter fixed value for reference Positive floating- 1 kg/Nl option is selected in the density. point number Corrected volume flow calculation parameter parameter.
  • Page 137 Proline Promass X 500 PROFIBUS PA Commissioning Navigation "Setup" menu → Advanced setup → Sensor adjustment → Zero point adjustment ‣ Zero point adjustment →  137 Zero point adjustment control →  137 Progress Parameter overview with brief description...
  • Page 138 Commissioning Proline Promass X 500 PROFIBUS PA Parameter overview with brief description Parameter Description Selection Factory setting Assign process variable Select process variable for totalizer. • Mass flow Mass flow • Volume flow • Corrected volume flow • Target mass flow •...
  • Page 139 Proline Promass X 500 PROFIBUS PA Commissioning 10.7.4 Carrying out additional display configurations In the Display submenu you can set all the parameters associated with the configuration of the local display. Navigation "Setup" menu → Advanced setup → Display ‣...
  • Page 140 Commissioning Proline Promass X 500 PROFIBUS PA Parameter overview with brief description Parameter Prerequisite Description Selection / User Factory setting entry Format display A local display is provided. Select how measured values • 1 value, max. size 1 value, max. size are shown on the display.
  • Page 141 Proline Promass X 500 PROFIBUS PA Commissioning Parameter Prerequisite Description Selection / User Factory setting entry Value 1 display A local display is provided. Select the measured value that • Mass flow Mass flow is shown on the local display. • Volume flow •...
  • Page 142 Commissioning Proline Promass X 500 PROFIBUS PA Parameter Prerequisite Description Selection / User Factory setting entry 0% bargraph value 1 A local display is provided. Enter 0% value for bar graph Signed floating-point Country-specific: display. number • 0 kg/h • 0 lb/min 100% bargraph value 1 A local display is provided.
  • Page 143 Proline Promass X 500 PROFIBUS PA Commissioning Parameter Prerequisite Description Selection / User Factory setting entry Display language A local display is provided. Set display language. • English English • Deutsch (alternatively, the • Français ordered language is • Español preset in the device) •...
  • Page 144 Commissioning Proline Promass X 500 PROFIBUS PA Security type →  144 WLAN passphrase →  144 Assign SSID name →  144 SSID name →  144 →  144 Apply changes Parameter overview with brief description Parameter Prerequisite Description User entry / ...
  • Page 145 Proline Promass X 500 PROFIBUS PA Commissioning Navigation "Setup" menu → Advanced setup → Configuration backup ‣ Configuration backup →  145 Operating time →  145 Last backup Configuration management →  145 Backup state →  145 Comparison result →...
  • Page 146 Commissioning Proline Promass X 500 PROFIBUS PA Options Description Compare The device configuration saved in the device memory is compared with the current device configuration of the HistoROM backup. Clear backup data The backup copy of the device configuration is deleted from the memory of the device.
  • Page 147 Proline Promass X 500 PROFIBUS PA Commissioning Using the parameter to reset the access code Navigation "Setup" menu → Advanced setup → Administration → Reset access code ‣ Reset access code Operating time →  147 Reset access code →  147...
  • Page 148 Commissioning Proline Promass X 500 PROFIBUS PA Navigation "Diagnostics" menu → Simulation ‣ Simulation →  149 Assign simulation process variable →  149 Process variable value Status input simulation →  149 Input signal level →  149 Current input 1 to n simulation →...
  • Page 149 Proline Promass X 500 PROFIBUS PA Commissioning Parameter overview with brief description Parameter Prerequisite Description Selection / User Factory setting entry / User interface Assign simulation process variable – Select a process variable for • Off the simulation process that is • Mass flow activated.
  • Page 150 Commissioning Proline Promass X 500 PROFIBUS PA Parameter Prerequisite Description Selection / User Factory setting entry / User interface Value current output 1 to n In the Current output 1 to n Enter the current value for 3.59 to 22.5 mA 3.59 mA simulation parameter, the On simulation.
  • Page 151 Proline Promass X 500 PROFIBUS PA Commissioning Parameter Prerequisite Description Selection / User Factory setting entry / User interface Diagnostic event simulation – Select a diagnostic event to • Off simulate this event. • Diagnostic event picklist (depends on the category selected) Logging interval –...
  • Page 152 Via Web browser, FieldCare, DeviceCare (via CDI-RJ45 service interface), fieldbus For a reset code, contact your Endress+Hauser service organization. 1. Navigate to the Reset access code parameter (→  147). 2. Enter the reset code.
  • Page 153 Proline Promass X 500 PROFIBUS PA Commissioning A0029673 1. Open the housing cover. 2. Remove the display module. 3. Fold open the terminal cover. 4. Setting the write protection (WP) switch on the main electronics module to the ON position enables hardware write protection.
  • Page 154 Commissioning Proline Promass X 500 PROFIBUS PA Proline 500 A0029630 Setting the write protection (WP) switch on the main electronics module to the ON position enables hardware write protection.  In the Locking status parameter the Hardware locked option is displayed →...
  • Page 155 Proline Promass X 500 PROFIBUS PA Operation Operation 11.1 Reading the device locking status Device active write protection: Locking status parameter Operation → Locking status Function scope of the "Locking status" parameter Options Description None The access status displayed in the Access status parameter applies →  73. Only appears on local display.
  • Page 156 Operation Proline Promass X 500 PROFIBUS PA 11.4.1 "Measured variables" submenu The Measured variables submenu contains all the parameters needed to display the current measured values for each process variable. Navigation "Diagnostics" menu → Measured values → Measured variables ‣...
  • Page 157 Proline Promass X 500 PROFIBUS PA Operation Parameter Prerequisite Description User interface Reference density – Displays the reference density currently Signed floating-point calculated. number Dependency The unit is taken from the Reference density unit parameter (→  104). Temperature –...
  • Page 158 Operation Proline Promass X 500 PROFIBUS PA Parameter overview with brief description Parameter Prerequisite Description Selection / User Factory setting entry / User interface Assign process variable – Select process variable for • Mass flow Mass flow totalizer. • Volume flow • Corrected volume flow •...
  • Page 159 Proline Promass X 500 PROFIBUS PA Operation Navigation "Diagnostics" menu → Measured values → Input values ‣ Input values ‣ →  159 Current input 1 to n ‣ →  159 Status input 1 to n Input values of current input The Current input 1 to n submenu contains all the parameters needed to display the current measured values for every current input.
  • Page 160 Operation Proline Promass X 500 PROFIBUS PA 11.4.4 Output values The Output values submenu contains all the parameters needed to display the current measured values for every output. Navigation "Diagnostics" menu → Measured values → Output values ‣ Output values ‣...
  • Page 161 Proline Promass X 500 PROFIBUS PA Operation Navigation "Diagnostics" menu → Measured values → Output values → Pulse/frequency/switch output 1 to n ‣ Pulse/frequency/switch output 1 to n Output frequency 1 to n →  161 Pulse output 1 to n →...
  • Page 162 Operation Proline Promass X 500 PROFIBUS PA 11.5 Adapting the measuring device to the process conditions The following are available for this purpose: • Basic settings using theSetup menu (→  101) • Advanced settings using theAdvanced setup submenu (→  134) 11.6...
  • Page 163 Proline Promass X 500 PROFIBUS PA Operation 11.7 Showing data logging The Extended HistoROM application package must be enabled in the device (order option) for the Data logging submenu to appear. This contains all the parameters for the measured value history.
  • Page 164 Operation Proline Promass X 500 PROFIBUS PA Data logging status →  166 Entire logging duration →  166 ‣ Display channel 1 ‣ Display channel 2 ‣ Display channel 3 ‣ Display channel 4 Endress+Hauser...
  • Page 165 Proline Promass X 500 PROFIBUS PA Operation Parameter overview with brief description Parameter Prerequisite Description Selection / User Factory setting entry / User interface Assign channel 1 The Extended HistoROM Assign process variable to • Off application package is logging channel. • Mass flow available.
  • Page 166 Operation Proline Promass X 500 PROFIBUS PA Parameter Prerequisite Description Selection / User Factory setting entry / User interface Assign channel 2 The Extended HistoROM Assign process variable to Picklist, see Assign application package is logging channel. channel 1 parameter available. (→  165) ...
  • Page 167 Proline Promass X 500 PROFIBUS PA Diagnostics and troubleshooting Diagnostics and troubleshooting 12.1 General troubleshooting For local display Error Possible causes Solution Local display dark and no output Supply voltage does not match the Apply the correct supply voltage .
  • Page 168 Diagnostics and troubleshooting Proline Promass X 500 PROFIBUS PA For output signals Error Possible causes Solution Signal output outside the valid Main electronics module is Order spare part →  241. range defective. Device shows correct value on local Configuration error...
  • Page 169 Proline Promass X 500 PROFIBUS PA Diagnostics and troubleshooting Error Possible causes Solution Web browser frozen and operation Data transfer active Wait until data transfer or current no longer possible action is finished. Connection lost 1. Check cable connection and power supply.
  • Page 170 Diagnostics and troubleshooting Proline Promass X 500 PROFIBUS PA 12.2 Diagnostic information via light emitting diodes 12.2.1 Transmitter Proline 500 – digital Different LEDs in the transmitter provide information on the device status. A0029689 Supply voltage Device status Not used...
  • Page 171 Proline Promass X 500 PROFIBUS PA Diagnostics and troubleshooting Color Meaning Service interface (CDI), Not connected or no connection established. Ethernet Link/Activity Yellow Connected and connection established. Flashing yellow Service interface active. Proline 500 Different LEDs in the transmitter provide information on the device status.
  • Page 172 Diagnostics and troubleshooting Proline Promass X 500 PROFIBUS PA Communication Communication Alarm Power Power A0029699 Communication Device status Supply voltage Color Meaning Communication White Communication active Device status Error Flashing red Warning Supply voltage Green Supply voltage is ok Supply voltage is off or too low...
  • Page 173 Proline Promass X 500 PROFIBUS PA Diagnostics and troubleshooting 12.3 Diagnostic information on local display 12.3.1 Diagnostic message Faults detected by the self-monitoring system of the measuring device are displayed as a diagnostic message in alternation with the operational display.
  • Page 174 Diagnostics and troubleshooting Proline Promass X 500 PROFIBUS PA Diagnostic behavior Symbol Meaning Alarm • Measurement is interrupted. • Signal outputs and totalizers assume the defined alarm condition. • A diagnostic message is generated. Warning Measurement is resumed. The signal outputs and totalizers are not affected. A diagnostic message is generated.
  • Page 175 Proline Promass X 500 PROFIBUS PA Diagnostics and troubleshooting 12.3.2 Calling up remedial measures X X X X X X X X X X X X X X 20.50 S801 Supply voltage Menu Diagnostic list Diagnostics 1 S801 Supply voltage...
  • Page 176 Diagnostics and troubleshooting Proline Promass X 500 PROFIBUS PA A0031056 Status area with status signal Diagnostic information→  174 Remedy information with Service ID In addition, diagnostic events which have occurred can be shown in the Diagnostics menu: • Via parameter •...
  • Page 177 Proline Promass X 500 PROFIBUS PA Diagnostics and troubleshooting Xxxxxx/…/…/ Device name: Xxxxxxx Mass flow: kg/h 12.34 Device tag: Xxxxxxx Volume flow: 12.34 m /h ³ Status signal: Function check (C) Xxxxxx Diagnostics 1: C485 Simu... Remedy information: Deactivate... Failure (F)
  • Page 178 Diagnostics and troubleshooting Proline Promass X 500 PROFIBUS PA The user is in the Diagnostics menu. 1. Call up the desired parameter. 2. On the right in the working area, mouse over the parameter.  A tool tip with remedy information for the diagnostic event appears.
  • Page 179 Proline Promass X 500 PROFIBUS PA Diagnostics and troubleshooting Coding Measuring value (hex) Byte 5 Quality Quality Substatus Limits A0032228-EN  38 Structure of the coding byte The content of the coding byte depends on the configured failsafe mode in the particular function block.
  • Page 180 Diagnostics and troubleshooting Proline Promass X 500 PROFIBUS PA Diagnostic information pertaining to the electronics: diagnostic number 200 to 399 Diagnostic number 200 to 301, 303 to 399 Measured value status (fixed assignment) Diagnostic behavior Device diagnosis Quality Coding Category...
  • Page 181 Proline Promass X 500 PROFIBUS PA Diagnostics and troubleshooting Measured value status (fixed assignment) Diagnostic behavior Device diagnosis Quality Coding Category (configurable) (fixed assignment) Quality Substatus (hex) (NE107) Logbook entry only GOOD 0x80 to 0x8E – – 12.7 Overview of diagnostic information •...
  • Page 182 Diagnostics and troubleshooting Proline Promass X 500 PROFIBUS PA Diagnostic information Remedy instructions Short text 046 Sensor limit exceeded 1. Inspect sensor 2. Check process condition Measured variable status [from the factory] Quality Good Quality substatus Maintenance demanded Coding (hex)
  • Page 183 Proline Promass X 500 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 062 Sensor connection faulty 1. Check or replace sensor electronic module (ISEM) 2. If available: Check connection cable between sensor and transmitter Measured variable status 3.
  • Page 184 Diagnostics and troubleshooting Proline Promass X 500 PROFIBUS PA Diagnostic information Remedy instructions Short text 063 Exciter current faulty 1. Check or replace sensor electronic module (ISEM) 2. If available: Check connection cable between sensor and transmitter Measured variable status 3.
  • Page 185 Proline Promass X 500 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 082 Data storage 1. Check module connections 2. Contact service Measured variable status Quality Quality substatus Maintenance alarm Coding (hex) 0x24 to 0x27 Status signal...
  • Page 186 Diagnostics and troubleshooting Proline Promass X 500 PROFIBUS PA Diagnostic information Remedy instructions Short text 083 Memory content 1. Restart device 2. Restore HistoROM S-DAT backup (' D evice reset' parameter) Measured variable status 3. Replace HistoROM S-DAT Quality Quality substatus...
  • Page 187 Proline Promass X 500 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 140 Sensor signal asymmetrical 1. Check or replace sensor electronic module (ISEM) 2. If available: Check connection cable between sensor and transmitter Measured variable status [from the factory] 3.
  • Page 188 Diagnostics and troubleshooting Proline Promass X 500 PROFIBUS PA Diagnostic information Remedy instructions Short text 144 Measuring error too high 1. Check or change sensor 2. Check process conditions Measured variable status [from the factory] Quality Quality substatus Maintenance alarm...
  • Page 189 Proline Promass X 500 PROFIBUS PA Diagnostics and troubleshooting 12.7.2 Diagnostic of electronic Diagnostic information Remedy instructions Short text 201 Device failure 1. Restart device 2. Contact service Measured variable status Quality Quality substatus Maintenance alarm Coding (hex) 0x24 to 0x27...
  • Page 190 Diagnostics and troubleshooting Proline Promass X 500 PROFIBUS PA Diagnostic information Remedy instructions Short text 242 Software incompatible 1. Check software 2. Flash or change main electronics module Measured variable status Quality Quality substatus Maintenance alarm Coding (hex) 0x24 to 0x27...
  • Page 191 Proline Promass X 500 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 252 Modules incompatible 1. Check electronic modules 2. Check if correct modules are available (e.g. NEx, Ex) Measured variable status 3. Replace electronic modules Quality...
  • Page 192 Diagnostics and troubleshooting Proline Promass X 500 PROFIBUS PA Diagnostic information Remedy instructions Short text 262 Sensor electronic connection faulty 1. Check or replace connection cable between sensor electronic module (ISEM) and main electronics Measured variable status 2. Check or replace ISEM or main electronics...
  • Page 193 Proline Promass X 500 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 270 Main electronic failure Change main electronic module Measured variable status Quality Quality substatus Maintenance alarm Coding (hex) 0x24 to 0x27 Status signal Diagnostic behavior...
  • Page 194 Diagnostics and troubleshooting Proline Promass X 500 PROFIBUS PA Diagnostic information Remedy instructions Short text 271 Main electronic failure 1. Restart device 2. Change main electronic module Measured variable status Quality Quality substatus Maintenance alarm Coding (hex) 0x24 to 0x27...
  • Page 195 Proline Promass X 500 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 272 Main electronic failure 1. Restart device 2. Contact service Measured variable status Quality Quality substatus Maintenance alarm Coding (hex) 0x24 to 0x27 Status signal...
  • Page 196 Diagnostics and troubleshooting Proline Promass X 500 PROFIBUS PA Diagnostic information Remedy instructions Short text 273 Main electronic failure Change electronic Measured variable status Quality Quality substatus Maintenance alarm Coding (hex) 0x24 to 0x27 Status signal Diagnostic behavior Alarm Influenced measured variables •...
  • Page 197 Proline Promass X 500 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 276 I/O module 1 to n faulty 1. Restart device 2. Change I/O module Measured variable status Quality Quality substatus Maintenance alarm Coding (hex) 0x24 to 0x27...
  • Page 198 Diagnostics and troubleshooting Proline Promass X 500 PROFIBUS PA Diagnostic information Remedy instructions Short text 302 Device verification active Device verification active, please wait. Measured variable status [from the factory] Quality Good Quality substatus Function check Coding (hex) 0xBC to 0xBF...
  • Page 199 Proline Promass X 500 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 311 Electronic failure 1. Do not reset device 2. Contact service Measured variable status Quality Quality substatus Maintenance alarm Coding (hex) 0x24 to 0x27 Status signal...
  • Page 200 Diagnostics and troubleshooting Proline Promass X 500 PROFIBUS PA Diagnostic information Remedy instructions Short text 332 Writing in HistoROM backup failed Replace user interface board Ex d/XP: replace transmitter Measured variable status Quality Quality substatus Maintenance alarm Coding (hex) 0x24 to 0x27...
  • Page 201 Proline Promass X 500 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 372 Sensor electronic (ISEM) faulty 1. Restart device 2. Check if failure recurs Measured variable status 3. Replace sensor electronic module (ISEM) Quality Quality substatus...
  • Page 202 Diagnostics and troubleshooting Proline Promass X 500 PROFIBUS PA Diagnostic information Remedy instructions Short text 373 Sensor electronic (ISEM) faulty 1. Transfer data or reset device 2. Contact service Measured variable status Quality Quality substatus Maintenance alarm Coding (hex) 0x24 to 0x27...
  • Page 203 Proline Promass X 500 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 375 I/O- 1 to n communication failed 1. Restart device 2. Check if failure recurs Measured variable status 3. Replace module rack inclusive electronic modules...
  • Page 204 Diagnostics and troubleshooting Proline Promass X 500 PROFIBUS PA Diagnostic information Remedy instructions Short text 382 Data storage 1. Insert T-DAT 2. Replace T-DAT Measured variable status Quality Quality substatus Maintenance alarm Coding (hex) 0x24 to 0x27 Status signal Diagnostic behavior...
  • Page 205 Proline Promass X 500 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 383 Memory content 1. Restart device 2. Delete T-DAT via ' R eset device' parameter Measured variable status 3. Replace T-DAT Quality Quality substatus Maintenance alarm...
  • Page 206 Diagnostics and troubleshooting Proline Promass X 500 PROFIBUS PA Diagnostic information Remedy instructions Short text 387 HistoROM backup failed Contact service organization Measured variable status Quality Quality substatus Maintenance alarm Coding (hex) 0x24 to 0x27 Status signal Diagnostic behavior Alarm Influenced measured variables •...
  • Page 207 Proline Promass X 500 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 331 Firmware update failed 1. Update firmware of device 2. Restart device Measured variable status Quality Quality substatus Maintenance alarm Coding (hex) 0x24 to 0x27...
  • Page 208 Diagnostics and troubleshooting Proline Promass X 500 PROFIBUS PA Diagnostic information Remedy instructions Short text 410 Data transfer 1. Check connection 2. Retry data transfer Measured variable status Quality Quality substatus Maintenance alarm Coding (hex) 0x24 to 0x27 Status signal...
  • Page 209 Proline Promass X 500 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 412 Processing download Download active, please wait Measured variable status Quality Uncertain Quality substatus Initial value Coding (hex) 0x4C to 0x4F Status signal Diagnostic behavior...
  • Page 210 Diagnostics and troubleshooting Proline Promass X 500 PROFIBUS PA Diagnostic information Remedy instructions Short text 437 Configuration incompatible 1. Restart device 2. Contact service Measured variable status Quality Quality substatus Maintenance alarm Coding (hex) 0x24 to 0x27 Status signal Diagnostic behavior...
  • Page 211 Proline Promass X 500 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 438 Dataset 1. Check data set file 2. Check device configuration Measured variable status 3. Up- and download new configuration Quality Uncertain Quality substatus Maintenance demanded...
  • Page 212 Diagnostics and troubleshooting Proline Promass X 500 PROFIBUS PA Diagnostic information Remedy instructions Short text 442 Frequency output 1 to n 1. Check process 2. Check frequency output settings Measured variable status [from the factory] Quality Good Quality substatus Function check...
  • Page 213 Proline Promass X 500 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 453 Flow override Deactivate flow override Measured variable status Quality Good Quality substatus Function check Coding (hex) 0xBC to 0xBF Status signal Diagnostic behavior Warning Influenced measured variables •...
  • Page 214 Diagnostics and troubleshooting Proline Promass X 500 PROFIBUS PA Diagnostic information Remedy instructions Short text 482 FB not Auto/Cas Set Block in AUTO mode Measured variable status Quality Good Quality substatus Coding (hex) 0x80 to 0x83 Status signal Diagnostic behavior...
  • Page 215 Proline Promass X 500 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 485 Measured variable simulation Deactivate simulation Measured variable status Quality Good Quality substatus Function check Coding (hex) 0xBC to 0xBF Status signal Diagnostic behavior Warning Influenced measured variables •...
  • Page 216 Diagnostics and troubleshooting Proline Promass X 500 PROFIBUS PA Diagnostic information Remedy instructions Short text 491 Current output 1 to n simulation Deactivate simulation Measured variable status Quality Good Quality substatus Function check Coding (hex) 0xBC to 0xBF Status signal...
  • Page 217 Proline Promass X 500 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 494 Switch output simulation 1 to n Deactivate simulation switch output Measured variable status Quality Good Quality substatus Function check Coding (hex) 0xBC to 0xBF...
  • Page 218 Diagnostics and troubleshooting Proline Promass X 500 PROFIBUS PA Diagnostic information Remedy instructions Short text 497 Simulation block output Deactivate simulation Measured variable status Quality Good Quality substatus Coding (hex) 0x80 to 0x83 Status signal Diagnostic behavior Warning Influenced measured variables –...
  • Page 219 Proline Promass X 500 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 529 Concentration settings faulty 1. Check concentration settings 2. Check input values e.g. pressure, temperature Measured variable status Quality Quality substatus Function check Coding (hex)
  • Page 220 Diagnostics and troubleshooting Proline Promass X 500 PROFIBUS PA 12.7.4 Diagnostic of process Diagnostic information Remedy instructions Short text 803 Current loop 1. Check wiring 2. Change I/O module Measured variable status Quality Quality substatus Process related Coding (hex) 0x28 to 0x2B...
  • Page 221 Proline Promass X 500 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 831 Sensor temperature too low Increase ambient temp. around the sensor housing Measured variable status [from the factory] Quality Uncertain Quality substatus Process related Coding (hex)
  • Page 222 Diagnostics and troubleshooting Proline Promass X 500 PROFIBUS PA Diagnostic information Remedy instructions Short text 832 Electronic temperature too high Reduce ambient temperature Measured variable status [from the factory] Quality Quality substatus Process related Coding (hex) 0x28 to 0x2B Status signal...
  • Page 223 Proline Promass X 500 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 833 Electronic temperature too low Increase ambient temperature Measured variable status [from the factory] Quality Quality substatus Process related Coding (hex) 0x28 to 0x2B Status signal...
  • Page 224 Diagnostics and troubleshooting Proline Promass X 500 PROFIBUS PA Diagnostic information Remedy instructions Short text 834 Process temperature too high Reduce process temperature Measured variable status [from the factory] Quality Uncertain Quality substatus Process related Coding (hex) 0x78 to 0x7B...
  • Page 225 Proline Promass X 500 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 835 Process temperature too low Increase process temperature Measured variable status [from the factory] Quality Uncertain Quality substatus Process related Coding (hex) 0x78 to 0x7B...
  • Page 226 Diagnostics and troubleshooting Proline Promass X 500 PROFIBUS PA Diagnostic information Remedy instructions Short text 842 Process limit Low flow cut off active! 1. Check low flow cut off configuration Measured variable status [from the factory] Quality Uncertain Quality substatus...
  • Page 227 Proline Promass X 500 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 882 Input signal 1. Check input configuration 2. Check external device or process conditions Measured variable status Quality Quality substatus Maintenance alarm Coding (hex) 0x24 to 0x27...
  • Page 228 Diagnostics and troubleshooting Proline Promass X 500 PROFIBUS PA Diagnostic information Remedy instructions Short text 910 Tubes not oscillating 1. Check electronic 2. Inspect sensor Measured variable status Quality Quality substatus Maintenance alarm Coding (hex) 0x24 to 0x27 Status signal...
  • Page 229 Proline Promass X 500 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 912 Medium inhomogeneous 1. Check process cond. 2. Increase system pressure Measured variable status [from the factory] Quality Uncertain Quality substatus Process related Coding (hex)
  • Page 230 Diagnostics and troubleshooting Proline Promass X 500 PROFIBUS PA Diagnostic information Remedy instructions Short text 913 Medium unsuitable 1. Check process conditions 2. Check electronic modules or sensor Measured variable status [from the factory] Quality Uncertain Quality substatus Process related...
  • Page 231 Proline Promass X 500 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 942 API density out of specification 1. Check process density with selected API commodity group 2. Check API related parameters Measured variable status Quality Quality substatus...
  • Page 232 Diagnostics and troubleshooting Proline Promass X 500 PROFIBUS PA Diagnostic information Remedy instructions Short text 944 Monitoring failed Check process conditions for Heartbeat Monitoring Measured variable status [from the factory] Quality Quality substatus Maintenance alarm Coding (hex) 0x24 to 0x27...
  • Page 233 Proline Promass X 500 PROFIBUS PA Diagnostics and troubleshooting 12.8 Pending diagnostic events The Diagnostics menu allows the user to view the current diagnostic event and the previous diagnostic event separately. To call up the measures to rectify a diagnostic event: •...
  • Page 234 Diagnostics and troubleshooting Proline Promass X 500 PROFIBUS PA / ../Diagnose list Diagnostics F273 Main electronic Diagnostics 2 Diagnostics 3 A0014006-EN  39 Taking the example of the local display To call up the measures to rectify a diagnostic event: •...
  • Page 235 Proline Promass X 500 PROFIBUS PA Diagnostics and troubleshooting 12.10.2 Filtering the event logbook Using the Filter options parameter you can define which category of event message is displayed in the Events list submenu. Navigation path Diagnostics → Event logbook → Filter options Filter categories •...
  • Page 236 Diagnostics and troubleshooting Proline Promass X 500 PROFIBUS PA Info number Info name I1451 Monitoring on I1457 Measured error verification failed I1459 I/O module verification failed I1460 HBSI verification failed I1461 Sensor verification failed I1462 Sensor electronic module verific. failed...
  • Page 237 Proline Promass X 500 PROFIBUS PA Diagnostics and troubleshooting 12.11.1 Function scope of the "Device reset" parameter Options Description Cancel No action is executed and the user exits the parameter. To delivery settings Every parameter for which a customer-specific default setting was ordered is reset to this customer-specific value.
  • Page 238 Diagnostics and troubleshooting Proline Promass X 500 PROFIBUS PA Parameter overview with brief description Parameter Description User interface Factory setting Device tag Shows name of measuring point. Max. 32 characters, such as Promass 500 PA letters, numbers or special characters (e.g. @, %, /).
  • Page 239 "Manufacturer' s information" document. The manufacturer' s information is available: • In the Download Area of the Endress+Hauser web site: www.endress.com → Downloads • Specify the following details: –...
  • Page 240 13.2 Measuring and test equipment Endress+Hauser offers a wide variety of measuring and test equipment, such as W@M or device tests. Your Endress+Hauser Sales Center can provide detailed information on the services.
  • Page 241 • The measuring devices have a modular design. • Spare parts are grouped into logical kits with the associated Installation Instructions. • Repairs are carried out by Endress+Hauser Service or by appropriately trained customers. • Certified devices can only be converted to other certified devices by Endress+Hauser Service or at the factory.
  • Page 242 Repairs Proline Promass X 500 PROFIBUS PA 14.5 Disposal 14.5.1 Removing the measuring device 1. Switch off the device. WARNING Danger to persons from process conditions. ‣ Beware of hazardous process conditions such as pressure in the measuring device, high temperatures or aggressive fluids.
  • Page 243 Various accessories, which can be ordered with the device or subsequently from Endress +Hauser, are available for the device. Detailed information on the order code in question is available from your local Endress+Hauser sales center or on the product page of the Endress+Hauser website: www.endress.com.
  • Page 244 Accessories Description Applicator Software for selecting and sizing Endress+Hauser measuring devices: • Choice of measuring devices for industrial requirements • Calculation of all the necessary data for identifying the optimum flowmeter: e.g. nominal diameter, pressure loss, flow velocity and accuracy.
  • Page 245 Proline Promass X 500 PROFIBUS PA Accessories 15.3 System components Accessories Description Memograph M graphic The Memograph M graphic data manager provides information on all the relevant data manager measured variables. Measured values are recorded correctly, limit values are monitored and measuring points analyzed. The data are stored in the 256 MB internal memory and also on a SD card or USB stick.
  • Page 246 Technical data Proline Promass X 500 PROFIBUS PA Technical data 16.1 Application The measuring device is suitable for flow measurement of liquids and gases only. Depending on the version ordered, the measuring device can also measure potentially explosive, flammable, poisonous and oxidizing media.
  • Page 247 Proline Promass X 500 PROFIBUS PA Technical data 16.3 Input Measured variable Direct measured variables • Mass flow • Density • Temperature Calculated measured variables • Volume flow • Corrected volume flow • Reference density Measuring range Measuring range for liquids Measuring range full scale values ...
  • Page 248 • Operating pressure to increase accuracy (Endress+Hauser recommends the use of a pressure measuring device for absolute pressure, e.g. Cerabar M or Cerabar S) •...
  • Page 249 Proline Promass X 500 PROFIBUS PA Technical data 16.4 Output Output signal PROFIBUS PA PROFIBUS PA In accordance with EN 50170 Volume 2, IEC 61158-2 (MBP), galvanically isolated Data transmission 31.25 kbit/s Current consumption 10 mA Permitted supply voltage 9 to 32 V...
  • Page 250 Technical data Proline Promass X 500 PROFIBUS PA Maximum input values DC 30 V, 250 mA (passive) Maximum output current 22.5 mA (active) Open-circuit voltage DC 28.8 V (active) Pulse width Adjustable: 0.05 to 2 000 ms Maximum pulse rate...
  • Page 251 Proline Promass X 500 PROFIBUS PA Technical data Relay output Function Switch output Version Relay output, galvanically isolated Switching behavior Can be set to: • NO (normally open), factory setting • NC (normally closed) Maximum switching • DC 30 V, 0.1 A capacity (passive) •...
  • Page 252 Technical data Proline Promass X 500 PROFIBUS PA Current output 0/4 to 20 mA 4 to 20 mA Failure mode Choose from: • 4 to 20 mA in accordance with NAMUR recommendation NE 43 • 4 to 20 mA in accordance with US •...
  • Page 253 Proline Promass X 500 PROFIBUS PA Technical data Interface/protocol • Via digital communication: PROFIBUS PA • Via service interface – CDI-RJ45 service interface – WLAN interface Plain text display With information on cause and remedial measures Web server Plain text display...
  • Page 254 Technical data Proline Promass X 500 PROFIBUS PA Compatibility with If the device is replaced, the measuring device Promass 500 supports the earlier model compatibility of the cyclic data with previous models. It is not necessary to adjust the engineering parameters of the PROFIBUS network with the Promass 500 GSD file.
  • Page 255 Proline Promass X 500 PROFIBUS PA Technical data terminals Spring-loaded terminals: Suitable for strands and strands with ferrules. Conductor cross-section 0.2 to 2.5 mm (24 to 12 AWG). Cable entries • Cable gland: M20 × 1.5 with cable ⌀ 6 to 12 mm (0.24 to 0.47 in) •...
  • Page 256 Technical data Proline Promass X 500 PROFIBUS PA Zero point stability Zero point stability [mm] [in] [kg/h] [lb/min] 5.03 5.03 5.03 Flow values Flow values as turndown parameter depending on nominal diameter. SI units 1:10 1:20 1:50 1:100 1:500 [mm]...
  • Page 257 Proline Promass X 500 PROFIBUS PA Technical data Mass flow (gases) ±0.25 % o.r. Density (liquids) ±0.00025 g/cm Temperature ±0.25 °C ± 0.0025 · T °C (±0.45 °F ± 0.0015 · (T–32) °F) Response time The response time depends on the configuration (damping).
  • Page 258 Technical data Proline Promass X 500 PROFIBUS PA Influence of medium The table below shows the effect on accuracy of mass flow due to a difference between pressure calibration pressure and process pressure. o.r. = of reading It is possible to compensate for the effect by: •...
  • Page 259 Proline Promass X 500 PROFIBUS PA Technical data 16.7 Installation "Mounting requirements" →  22 16.8 Environment Ambient temperature →  25 range Temperature tables Observe the interdependencies between the permitted ambient and fluid temperatures when operating the device in hazardous areas.
  • Page 260 Technical data Proline Promass X 500 PROFIBUS PA 16.9 Process Medium temperature range –50 to +180 °C (–58 to +356 °F) Dependency of ambient temperature on medium temperature A0031121  41 Exemplary representation, values in the table below. Ambient temperature...
  • Page 261 Proline Promass X 500 PROFIBUS PA Technical data the sensor housing. Therefore, the use of a rupture disk is strongly recommended in applications involving high gas pressures, and particularly in applications in which the process pressure is greater than 2/3 of the sensor housing burst pressure.
  • Page 262 Technical data Proline Promass X 500 PROFIBUS PA • The minimum recommended full scale value is approx. 1/20 of the maximum full scale value • In most applications, 20 to 50 % of the maximum full scale value can be considered ideal •...
  • Page 263 Proline Promass X 500 PROFIBUS PA Technical data Materials Transmitter housing Housing of Proline 500 – digital transmitter Order code for "Transmitter housing": • Option A "Aluminum coated": aluminum, AlSi10Mg, coated • Option D "Polycarbonate": polycarbonate Housing of Proline 500 transmitter Order code for "Transmitter housing":...
  • Page 264 Technical data Proline Promass X 500 PROFIBUS PA Cable entries and adapters Material • Adapter for cable entry with internal thread G ½" Stainless steel, 1.4404 (316L) • Adapter for cable entry with internal thread NPT ½"  Only available for certain device versions: •...
  • Page 265 Proline Promass X 500 PROFIBUS PA Technical data External WLAN antenna • Antenna: ASA plastic (acrylic ester-styrene-acrylonitrile) and nickel-plated brass • Adapter: Stainless steel and nickel-plated brass • Cable: Polyethylene • Plug: Nickel-plated brass • Angle bracket: Stainless steel Process connections Fixed flange connections: –...
  • Page 266 Technical data Proline Promass X 500 PROFIBUS PA A0028232  43 Operation with touch control Proline 500 – digital Proline 500 Display elements • 4-line, illuminated, graphic display • White background lighting; switches to red in event of device errors •...
  • Page 267 Proline Promass X 500 PROFIBUS PA Technical data Supported operating Operating unit Interface Additional information tools Web browser Notebook, PC or tablet • CDI-RJ45 service Special Documentation for with Web browser interface device →  274 • WLAN interface DeviceCare SFE100 Notebook, PC or tablet •...
  • Page 268 Technical data Proline Promass X 500 PROFIBUS PA HistoROM The measuring device features HistoROM data management. HistoROM data management data management comprises both the storage and import/export of key device and process data, making operation and servicing far more reliable, secure and efficient.
  • Page 269 The device meets the legal requirements of the applicable EU Directives. These are listed in the corresponding EU Declaration of Conformity along with the standards applied. Endress+Hauser confirms successful testing of the device by affixing to it the CE mark. C-Tick symbol The measuring system meets the EMC requirements of the "Australian Communications...
  • Page 270 • With the identification PED/G1/x (x = category) on the sensor nameplate, Directive Endress+Hauser confirms conformity with the "Essential Safety Requirements" specified in Appendix I of the Pressure Equipment Directive 2014/68/EU. • Devices not bearing this marking (PED) are designed and manufactured according to good engineering practice.
  • Page 271 The application packages can be ordered with the device or subsequently from Endress+Hauser. Detailed information on the order code in question is available from your local Endress+Hauser sales center or on the product page of the Endress+Hauser website: www.endress.com.
  • Page 272 Technical data Proline Promass X 500 PROFIBUS PA Heartbeat Technology Package Description Heartbeat Verification Heartbeat Verification +Monitoring Meets the requirement for traceable verification to DIN ISO 9001:2008 Chapter 7.6 a) "Control of monitoring and measuring equipment". • Functional testing in the installed state without interrupting the process.
  • Page 273 For an overview of the scope of the associated Technical Documentation, refer to the following: • W@M Device Viewer (www.endress.com/deviceviewer): Enter the serial number from nameplate • Endress+Hauser Operations App: Enter the serial number from the nameplate or scan the 2D matrix code (QR code) on the nameplate Standard documentation Brief Operating Instructions...
  • Page 274 Technical data Proline Promass X 500 PROFIBUS PA Special Documentation Contents Documentation code Information on the Pressure Equipment Directive SD01614D Radio approvals for WLAN interface for A309/A310 display module SD01793D Web server SD01668D Heartbeat Technology SD01705D Concentration measurement SD01711D Petroleum...
  • Page 275 Proline Promass X 500 PROFIBUS PA Index Index Connection preparations ..... . 41 Connection tools ......35 About this document .
  • Page 276 Index Proline Promass X 500 PROFIBUS PA Display Filtering the event logbook ....235 see Onsite display Firmware Display area Release date ......87 For operational display .
  • Page 277 Proline Promass X 500 PROFIBUS PA Index Transmitter ......17 Navigation path (navigation view) ....65 Main electronics module .
  • Page 278 Index Proline Promass X 500 PROFIBUS PA Pulse/frequency/switch output (Wizard) 117, Repairs ........241 119, Notes .
  • Page 279 Proline Promass X 500 PROFIBUS PA Index Special connection instructions ....53 For submenu ......66 Standards and guidelines .
  • Page 280 Index Proline Promass X 500 PROFIBUS PA Vibration resistance ......259 Vibrations ....... . . 27 W@M .
  • Page 282 www.addresses.endress.com...