Endress+Hauser Proline Promass I 300 PROFIBUS PA Operating Instructions Manual

Endress+Hauser Proline Promass I 300 PROFIBUS PA Operating Instructions Manual

Coriolis flowmeter

Advertisement

Quick Links

BA01509D/06/EN/02.18
71415066
2018-11-01
Valid as of version
01.01.zz (Device firmware)
Products
Operating Instructions
Proline Promass I 300
PROFIBUS PA
Coriolis flowmeter
Solutions
Services

Advertisement

Table of Contents
loading

Summary of Contents for Endress+Hauser Proline Promass I 300 PROFIBUS PA

  • Page 1 Products Solutions Services BA01509D/06/EN/02.18 71415066 2018-11-01 Valid as of version 01.01.zz (Device firmware) Operating Instructions Proline Promass I 300 PROFIBUS PA Coriolis flowmeter...
  • Page 2 • The manufacturer reserves the right to modify technical data without prior notice. Your Endress+Hauser Sales Center will supply you with current information and updates to these instructions. Endress+Hauser...
  • Page 3 Proline Promass I 300 PROFIBUS PA Table of contents Table of contents About this document ....6 Installation ..... . . 22 Document function .
  • Page 4 Table of contents Proline Promass I 300 PROFIBUS PA 8.3.10 User roles and related access 10.6.6 Displaying the I/O configuration ..96 authorization ....59 10.6.7 Configuring the current input .
  • Page 5 13.2 Measuring and test equipment ... 220 13.3 Endress+Hauser services ....220 Repairs ......221 14.1 General notes .
  • Page 6 About this document Proline Promass I 300 PROFIBUS PA About this document Document function These Operating Instructions contain all the information that is required in various phases of the life cycle of the device: from product identification, incoming acceptance and storage, to mounting, connection, operation and commissioning through to troubleshooting, maintenance and disposal.
  • Page 7 Proline Promass I 300 PROFIBUS PA About this document Symbol Meaning Light emitting diode is on. Light emitting diode is flashing. 1.2.4 Tool symbols Symbol Meaning Flat blade screwdriver Allen key Open-ended wrench 1.2.5 Symbols for certain types of information...
  • Page 8 • W@M Device Viewer (www.endress.com/deviceviewer): Enter the serial number from nameplate • Endress+Hauser Operations App: Enter the serial number from the nameplate or scan the 2D matrix code (QR code) on the nameplate Detailed list of the individual documents along with the documentation code →...
  • Page 9 Proline Promass I 300 PROFIBUS PA About this document TRI-CLAMP® Registered trademark of Ladish & Co., Inc., Kenosha, USA Endress+Hauser...
  • Page 10 Basic safety instructions Proline Promass I 300 PROFIBUS PA Basic safety instructions Requirements for the personnel The personnel for installation, commissioning, diagnostics and maintenance must fulfill the following requirements: ‣ Trained, qualified specialists must have a relevant qualification for this specific function and task.
  • Page 11 Verification for borderline cases: ‣ For special fluids and fluids for cleaning, Endress+Hauser is glad to provide assistance in verifying the corrosion resistance of fluid-wetted materials, but does not accept any warranty or liability as minute changes in the temperature, concentration or level of contamination in the process can alter the corrosion resistance properties.
  • Page 12 Proline Promass I 300 PROFIBUS PA It meets general safety standards and legal requirements. It also complies with the EU directives listed in the device-specific EU Declaration of Conformity. Endress+Hauser confirms this by affixing the CE mark to the device.
  • Page 13 Proline Promass I 300 PROFIBUS PA Basic safety instructions • User-specific access code Protect write access to the device parameters via the local display, Web browser or operating tool (e.g. FieldCare, DeviceCare). Access authorization is clearly regulated through the use of a user-specific access code.
  • Page 14 Basic safety instructions Proline Promass I 300 PROFIBUS PA 2.7.4 Access via service interface (CDI-RJ45) The device can be connected to a network via the service interface (CDI-RJ45). Device- specific functions guarantee the secure operation of the device in a network.
  • Page 15 Proline Promass I 300 PROFIBUS PA Product description Product description The device consists of a transmitter and a sensor. The device is available as a compact version: The transmitter and sensor form a mechanical unit. Product design N ic te r e rg ö...
  • Page 16 Technical Documentation present? • If one of the conditions is not satisfied, contact your Endress+Hauser Sales Center. • Depending on the device version, the CD-ROM might not be part of the delivery! The Technical Documentation is available via the Internet or via the Endress+Hauser Operations App, see the "Product identification"...
  • Page 17  8 sections • The W@M Device Viewer: enter the serial number from the nameplate (www.endress.com/deviceviewer) • The Endress+Hauser Operations App: Enter the serial number from the nameplate or scan the 2-D matrix code (QR code) on the nameplate. 4.2.1...
  • Page 18 Incoming acceptance and product identification Proline Promass I 300 PROFIBUS PA 4.2.2 Sensor nameplate Order code: Ser. no.: Ext. ord. cd.: Date: A0029199  3 Example of a sensor nameplate Name of the sensor Manufacturing location Order code Serial number (ser. no.) Extended order code (Ext.
  • Page 19 Proline Promass I 300 PROFIBUS PA Incoming acceptance and product identification 4.2.3 Symbols on measuring device Symbol Meaning WARNING! This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in serious or fatal injury. Reference to documentation Refers to the corresponding device documentation.
  • Page 20 Storage and transport Proline Promass I 300 PROFIBUS PA Storage and transport Storage conditions Observe the following notes for storage: ‣ Store in the original packaging to ensure protection from shock. ‣ Do not remove protective covers or protective caps installed on process connections.
  • Page 21 Proline Promass I 300 PROFIBUS PA Storage and transport 5.2.2 Measuring devices with lifting lugs CAUTION Special transportation instructions for devices with lifting lugs ‣ Only use the lifting lugs fitted on the device or flanges to transport the device.
  • Page 22 Installation Proline Promass I 300 PROFIBUS PA Installation Installation conditions No special measures such as supports are necessary. External forces are absorbed by the construction of the device. 6.1.1 Mounting position Mounting location A0028772 To prevent measuring errors arising from accumulation of gas bubbles in the measuring tube, avoid the following mounting locations in the pipe: •...
  • Page 23 Proline Promass I 300 PROFIBUS PA Installation Ø orifice plate, pipe restriction [mm] [in] [mm] [in] ³⁄₈ 0.24 ½ 0.40 15 FB ½ FB 0.60 0.55 25 FB 1 FB 0.95 1½ 0.87 40 FB 1½ FB 1.38 1.10 50 FB 2 FB 2.13...
  • Page 24 If operating outdoors: Avoid direct sunlight, particularly in warm climatic regions. You can order a weather protection cover from Endress+Hauser. →  223. System pressure It is important that cavitation does not occur, or that gases entrained in the liquids do not outgas.
  • Page 25 Proline Promass I 300 PROFIBUS PA Installation NOTICE Electronics overheating on account of thermal insulation! ‣ Recommended orientation: horizontal orientation, transmitter housing pointing downwards. ‣ Do not insulate the transmitter housing . ‣ Maximum permissible temperature at the lower end of the transmitter housing: 80 °C (176 °F)
  • Page 26 Installation Proline Promass I 300 PROFIBUS PA Vibrations The high oscillation frequency of the measuring tubes ensures that the correct operation of the measuring system is not influenced by plant vibrations. 6.1.3 Special mounting instructions Drainability When installed vertically, the measuring tube can be drained completely and protected against buildup.
  • Page 27 Proline Promass I 300 PROFIBUS PA Installation [mm] [in] [mm] [in] [mm] [in] [mm] [in] 14.69 0.79 1.57 16.1 0.79 1.57 15 FB 15 FB 21.22 1.18 44.5 1.75 21.22 1.18 44.5 1.75 25 FB 25 FB 26.3 2.36 26.3 2.36...
  • Page 28 Installation Proline Promass I 300 PROFIBUS PA SW 2.5 5 (0.2) min. 15 (0.6) A0029800 Cover borehole for the securing screw Securing screw to lock the cover Mounting the measuring device 6.2.1 Required tools For sensor For flanges and other process connections: Corresponding mounting tools 6.2.2...
  • Page 29 Proline Promass I 300 PROFIBUS PA Installation 2. Install the measuring device or turn the transmitter housing so that the cable entries do not point upwards.  A0029263 6.2.4 Turning the transmitter housing To provide easier access to the connection compartment or display module, the transmitter housing can be turned.
  • Page 30 Installation Proline Promass I 300 PROFIBUS PA – – – 3 mm A0030035 1. Depending on the device version: Loosen the securing clamp of the connection compartment cover. 2. Unscrew the connection compartment cover. 3. Turn the display module to the desired position: max. 8 × 45° in each direction.
  • Page 31 Proline Promass I 300 PROFIBUS PA Electrical connection Electrical connection NOTICE The measuring device does not have an internal circuit breaker. ‣ For this reason, assign the measuring device a switch or power-circuit breaker so that the power supply line can be easily disconnected from the mains.
  • Page 32 Electrical connection Proline Promass I 300 PROFIBUS PA Pulse/frequency/switch output Standard installation cable is sufficient. Relay output Standard installation cable is sufficient. Current input 0/4 to 20 mA Standard installation cable is sufficient. Status input Standard installation cable is sufficient.
  • Page 33 Proline Promass I 300 PROFIBUS PA Electrical connection Maximum 24 µH/Ω for Zone 1, Class I, Division 1 Cable length Maximum 300 m (1 000 ft), see the following table Max. cable length for use in Non-hazardous area, Cross-section Ex Zone 2, Class I, Division 2 Ex Zone 1, Class I, Division 1 0.34 mm...
  • Page 34 Electrical connection Proline Promass I 300 PROFIBUS PA 7.1.3 Terminal assignment Transmitter: supply voltage, input/outputs The terminal assignment of the inputs and outputs depends on the individual order version of the device. The device-specific terminal assignment is documented on an adhesive label in the terminal cover.
  • Page 35 Proline Promass I 300 PROFIBUS PA Electrical connection unrestricted operation when EMC interference is present. These measures have been taken into account for this device. Operation in the event of disturbance variables as per NAMUR NE21 is thus guaranteed. 1. Observe national installation requirements and guidelines during installation.
  • Page 36 Electrical connection Proline Promass I 300 PROFIBUS PA 2. If the measuring device is supplied without cable glands: Provide suitable cable gland for corresponding connecting cable. 3. If the measuring device is supplied with cable glands: Observe requirements for connecting cables →  31.
  • Page 37 Proline Promass I 300 PROFIBUS PA Electrical connection N ic N ic te r te r e rg ö ff e rg ö ff iz e iz e te n te n ri r ri r s io s io te r ö...
  • Page 38 Electrical connection Proline Promass I 300 PROFIBUS PA Removing a cable 3 (0.12) A0029598  7 Engineering unit mm (in) 1. To remove a cable from the terminal, use a flat-blade screwdriver to push the slot between the two terminal holes 2.
  • Page 39 Proline Promass I 300 PROFIBUS PA Electrical connection 7.2.2 Connecting the remote display and operating module DKX001 The remote display and operating module DKX001 is available as an optional extra →  223. • The remote display and operating module DKX001 is only available for the following housing versions, order code for "Housing":...
  • Page 40 Electrical connection Proline Promass I 300 PROFIBUS PA Special connection instructions 7.4.1 Connection examples PROFIBUS PA A0028768  8 Connection example for PROFIBUS PA Control system (e.g. PLC) PROFIBUS PA segment coupler Cable shield: the cable shield must be grounded at both ends to comply with EMC requirements; observe cable...
  • Page 41 Proline Promass I 300 PROFIBUS PA Electrical connection 4...20 mA A0028759  10 Connection example for 4-20 mA current output (passive) Automation system with current input (e.g. PLC) Active barrier for power supply (e.g. RN221N) Analog display unit: observe maximum load...
  • Page 42 Electrical connection Proline Promass I 300 PROFIBUS PA Relay output A0028760  13 Connection example for relay output (passive) Automation system with relay input (e.g. PLC) Power supply Transmitter: Observe input values →  232 Current input A0028915  14...
  • Page 43 Proline Promass I 300 PROFIBUS PA Electrical connection Hardware settings 7.5.1 Setting the device address The address must always be configured for a PROFIBUS DP/PA device. The valid address range is between 1 and 126. In a PROFIBUS DP/PA network, each address can only be assigned once.
  • Page 44 Electrical connection Proline Promass I 300 PROFIBUS PA Activating the default IP address via the DIP switch Risk of electric shock when opening the transmitter housing. ‣ Before opening the transmitter housing: ‣ Disconnect the device from the power supply.
  • Page 45 Proline Promass I 300 PROFIBUS PA Electrical connection Post-connection check Are cables or the device undamaged (visual inspection)?  Do the cables used meet the requirements?  Do the cables have adequate strain relief?  Are all the cable glands installed, firmly tightened and leak-tight? Cable run with "water trap"...
  • Page 46 Operation options Proline Promass I 300 PROFIBUS PA Operation options Overview of operation options A0034513 Local operation via display module Computer with Web browser (e.g. Internet Explorer) or with operating tool (e.g. FieldCare, DeviceCare, AMS Device Manager, SIMATIC PDM) Field Xpert SFX350 or SFX370...
  • Page 47 Proline Promass I 300 PROFIBUS PA Operation options Structure and function of the operating menu 8.2.1 Structure of the operating menu For an overview of the operating menu for experts: "Description of Device Parameters" document supplied with the device→  256...
  • Page 48 Operation options Proline Promass I 300 PROFIBUS PA 8.2.2 Operating philosophy The individual parts of the operating menu are assigned to certain user roles (operator, maintenance etc.). Each user role contains typical tasks within the device lifecycle. Menu/parameter User role and tasks...
  • Page 49 Proline Promass I 300 PROFIBUS PA Operation options Menu/parameter User role and tasks Content/meaning Expert function-oriented Tasks that require detailed Contains all the parameters of the device and makes it possible to access these knowledge of the function of the parameters directly using an access code.
  • Page 50 Operation options Proline Promass I 300 PROFIBUS PA Status area The following symbols appear in the status area of the operational display at the top right: • Status signals→  153 – F: Failure – C: Function check – S: Out of specification –...
  • Page 51 Proline Promass I 300 PROFIBUS PA Operation options 8.3.2 Navigation view In the submenu In the wizard /../Operation 0091-1 /../Select medium Access stat.disp Select medium Operator Liquid Locking status Display A0013993-EN A0013995-EN Navigation view Navigation path to current position Status area Display area for navigation Operating elements →...
  • Page 52 Operation options Proline Promass I 300 PROFIBUS PA Display area Menus Symbol Meaning Operation Appears: • In the menu next to the "Operation" selection • At the left in the navigation path in the Operation menu Setup Appears: • In the menu next to the "Setup" selection •...
  • Page 53 Proline Promass I 300 PROFIBUS PA Operation options 8.3.3 Editing view Numeric editor +0.000 Xx – A0034250  17 For entering values in parameters (e.g. limit values) Entry display area Input screen Confirm, delete or reject entry Operating elements Text editor...
  • Page 54 Operation options Proline Promass I 300 PROFIBUS PA Operating key(s) Meaning Enter key • Press the key briefly: confirm your selection. • Press the key for 2 s: confirm the entry. Escape key combination (press keys simultaneously) Close the editing view without accepting the changes.
  • Page 55 Proline Promass I 300 PROFIBUS PA Operation options 8.3.4 Operating elements Operating key(s) Meaning Minus key In a menu, submenu Moves the selection bar upwards in a picklist. With a Wizard Confirms the parameter value and goes to the previous parameter.
  • Page 56 Operation options Proline Promass I 300 PROFIBUS PA Calling up and closing the context menu The user is in the operational display. 1. Press the  and  keys for longer than 3 seconds.  The context menu opens. XXXXXXXXXX Setup Conf.backup...
  • Page 57 Proline Promass I 300 PROFIBUS PA Operation options 8.3.6 Navigating and selecting from list Different operating elements are used to navigate through the operating menu. The navigation path is displayed on the left in the header. Icons are displayed in front of the individual menus.
  • Page 58 Operation options Proline Promass I 300 PROFIBUS PA The direct access code consists of a 5-digit number (at maximum) and the channel number, which identifies the channel of a process variable: e.g. 00914-2. In the navigation view, this appears on the right-hand side in the header of the selected parameter.
  • Page 59 Proline Promass I 300 PROFIBUS PA Operation options Ent. access code Invalid or out of range input value Min:0 Max:9999 A0014049-EN For a description of the editing view - consisting of the text editor and numeric editor - with symbols →  53, for a description of the operating elements →  55 8.3.10...
  • Page 60 Operation options Proline Promass I 300 PROFIBUS PA 2. Enter the access code.  The -symbol in front of the parameters disappears; all previously write- protected parameters are now re-enabled. 8.3.12 Enabling and disabling the keypad lock The keypad lock makes it possible to block access to the entire operating menu via local operation.
  • Page 61 Proline Promass I 300 PROFIBUS PA Operation options 8.4.2 Prerequisites Computer hardware Hardware Interface CDI-RJ45 WLAN Interface The computer must have an RJ45 The operating unit must have a interface. WLAN interface. Connection Standard Ethernet cable with RJ45 Connection via Wireless LAN.
  • Page 62 Operation options Proline Promass I 300 PROFIBUS PA Measuring device: Via CDI-RJ45 service interface Device CDI-RJ45 service interface Measuring device The measuring device has an RJ45 interface. Web server Web server must be enabled; factory setting: ON  For information on enabling the Web server →  66...
  • Page 63 Proline Promass I 300 PROFIBUS PA Operation options Via WLAN interface Configuring the Internet protocol of the mobile terminal NOTICE If the WLAN connection is lost during the configuration, settings made may be lost. ‣ Make sure that the WLAN connection is not disconnected while configuring the device.
  • Page 64 Operation options Proline Promass I 300 PROFIBUS PA 2. Enter the IP address of the Web server in the address line of the Web browser: 192.168.1.212  The login page appears. 2 3 4 A0029417 Picture of device Device name...
  • Page 65 Proline Promass I 300 PROFIBUS PA Operation options 8.4.5 User interface A0029418 Function row Local display language Navigation area Header The following information appears in the header: • Device name • Device tag • Device status with status signal →  156 •...
  • Page 66 Operation options Proline Promass I 300 PROFIBUS PA Navigation area If a function is selected in the function bar, the submenus of the function open in the navigation area. The user can now navigate through the menu structure. Working area...
  • Page 67 Proline Promass I 300 PROFIBUS PA Operation options 3. If no longer needed: Reset modified properties of the Internet protocol (TCP/IP) →  62. Access to the operating menu via the operating tool The structure of the operating menu in the operating tools is the same as for operation via the local display.
  • Page 68 Operation options Proline Promass I 300 PROFIBUS PA A0027563  21 Connection via service interface (CDI-RJ45) Computer with Web browser (e.g. Microsoft Internet Explorer, Microsoft Edge) for accessing the integrated device Web server or with "FieldCare", "DeviceCare" operating tool with COM DTM "CDI Communication TCP/IP"...
  • Page 69 FieldCare Function scope FDT-based plant asset management tool from Endress+Hauser. It can configure all smart field devices in a system and helps you manage them. By using the status information, it is also a simple but effective way of checking their status and condition.
  • Page 70 Operation options Proline Promass I 300 PROFIBUS PA Typical functions: • Configuring parameters of transmitters • Loading and saving device data (upload/download) • Documentation of the measuring point • Visualization of the measured value memory (line recorder) and event logbook...
  • Page 71 DeviceCare Function scope Tool to connect and configure Endress+Hauser field devices. The fastest way to configure Endress+Hauser field devices is with the dedicated "DeviceCare" tool. Together with the device type managers (DTMs) it presents a convenient, comprehensive solution. For details, see Innovation Brochure IN01047S Source for device description files See information →...
  • Page 72 Operation options Proline Promass I 300 PROFIBUS PA Source for device description files See data →  73 Endress+Hauser...
  • Page 73 Proline Promass I 300 PROFIBUS PA System integration System integration Overview of device description files 9.1.1 Current version data for the device Firmware version 01.01.zz • On the title page of the Operating instructions • On the transmitter nameplate • Firmware version Diagnostics →...
  • Page 74 System integration Proline Promass I 300 PROFIBUS PA 9.2.1 Manufacturer-specific GSD This GSD guarantees the unrestricted functionality of the measuring device. Device-specific process parameters and functions are therefore available. Manufacturer-specific GSD ID number File name PROFIBUS PA 0x156D EH3x156D.gsd Use manufacturer-specific GSD Assignment is performed in the Ident number selector parameter via the Manufacturer option.
  • Page 75 Proline Promass I 300 PROFIBUS PA System integration Compatibility with earlier model If the device is replaced, the measuring device Promass 300 supports the compatibility of the cyclic data with previous models. It is not necessary to adjust the engineering parameters of the PROFIBUS network with the Promass 300 GSD file.
  • Page 76 System integration Proline Promass I 300 PROFIBUS PA 2. Set the device address: The same device address that was set for the Promass 80 or Promass 83 PROFIBUS PA must be used. 3. Connect the measuring device Promass 300 PROFIBUS PA.
  • Page 77 Proline Promass I 300 PROFIBUS PA System integration Previous model: Promass 83 PROFIBUS PA Control variable Function Support 0 → 2 Positive zero return: ON 0 → 3 Positive zero return: OFF 0 → 4 Zero point adjustment: START 0 → 8...
  • Page 78 System integration Proline Promass I 300 PROFIBUS PA Cyclic data transmission Cyclic data transmission when using the device master file (GSD). 9.5.1 Block model The block model shows which input and output data the measuring device makes available for cyclic data exchange. Cyclic data exchange takes place with a PROFIBUS master (Class 1), e.g.
  • Page 79 Proline Promass I 300 PROFIBUS PA System integration AI module (Analog Input) Transmit an input variable from the measuring device to the PROFIBUS master (Class 1). The selected input variable, along with the status, is cyclically transmitted to the PROFIBUS Master (Class 1) via the AI module. The input variable is depicted in the first four bytes in the form of a floating point number as per the IEEE 754 standard.
  • Page 80 System integration Proline Promass I 300 PROFIBUS PA Factory setting Function block Factory setting AI 1 Mass flow AI 2 Volume flow AI 3 Corrected volume flow AI 4 Density AI 5 Mass flow AI 6 Temperature AI 7 Mass flow...
  • Page 81 Proline Promass I 300 PROFIBUS PA System integration SETTOT_TOTAL module The module combination consists of the SETTOT and TOTAL functions: • SETTOT: Control the totalizers via the PROFIBUS master. • TOTAL: Transmit totalizer value, along with the status, to the PROFIBUS master.
  • Page 82 System integration Proline Promass I 300 PROFIBUS PA Data structure Output data of SETTOT and MODETOT Byte 1 Byte 2 Control variable 1: SETTOT Control variable 2: MODETOT Input data of TOTAL Byte 1 Byte 2 Byte 3 Byte 4...
  • Page 83 Proline Promass I 300 PROFIBUS PA System integration Selection: device function Device function Factory setting: Status (meaning) Empty pipe detection • 0 (device function not active) • 1 (device function active) Low flow cut off • Bit 0: Verification status - Check not done •...
  • Page 84 System integration Proline Promass I 300 PROFIBUS PA Assignment of medium type: function block DO 5 Fructose in water Glucose in water Hydrogen peroxide in water Sucrose in water Invert sugar in water Nitric acid Phosphoric acid Potassium hydroxide Sodium hydroxide...
  • Page 85 Proline Promass I 300 PROFIBUS PA Commissioning Commissioning 10.1 Function check Before commissioning the measuring device: ‣ Make sure that the post-installation and post-connection checks have been performed. • "Post-installation check" checklist→  30 • "Post-connection check" checklist →  45 10.2...
  • Page 86 Commissioning Proline Promass I 300 PROFIBUS PA X X X X X X X 20.50 Main menu 0104-1 Display language English Operation Setup Display language 0104-1 English à Deutsch Español Français Display language 0104-1 à English Deutsch Español Français Hauptmenü...
  • Page 87: Table Of Contents

    Proline Promass I 300 PROFIBUS PA Commissioning Navigation "Setup" menu  Setup Device tag →  88 ‣ System units →  88 ‣ Medium selection →  91 ‣ Communication →  92 ‣ Analog inputs →  94 ‣...
  • Page 88 Commissioning Proline Promass I 300 PROFIBUS PA XXXXXXXXX A0029422  24 Header of the operational display with tag name Tag name Enter the tag name in the "FieldCare" operating tool →  71 Navigation "Setup" menu → Device tag Parameter overview with brief description...
  • Page 89 Proline Promass I 300 PROFIBUS PA Commissioning Temperature unit →  90 Pressure unit →  90 Parameter overview with brief description Parameter Description Selection Factory setting Mass flow unit Select mass flow unit. Unit choose list Country-specific: • kg/h Result •...
  • Page 90 Commissioning Proline Promass I 300 PROFIBUS PA Parameter Description Selection Factory setting Temperature unit Select temperature unit. Unit choose list Country-specific: • °C Result • °F The selected unit applies for: • Electronic temperature parameter (6053) • Maximum value parameter (6051) •...
  • Page 91: Medium Selection

    Proline Promass I 300 PROFIBUS PA Commissioning 10.6.3 Selecting and setting the medium The Select medium wizard submenu contains parameters that must be configured in order to select and set the medium. Navigation "Setup" menu → Select medium ‣ Medium selection Select medium →...
  • Page 92 Commissioning Proline Promass I 300 PROFIBUS PA Parameter overview with brief description Parameter Prerequisite Description Selection / User Factory setting entry / User interface Select medium – Select medium type. • Liquid Liquid • Gas Select gas type The Gas option is selected in Select measured gas type.
  • Page 93: Communication

    Proline Promass I 300 PROFIBUS PA Commissioning Navigation "Setup" menu → Communication ‣ Communication →  93 Device address Parameter overview with brief description Parameter Description User entry Factory setting Device address Enter device address. 0 to 126 Endress+Hauser...
  • Page 94: Analog Inputs

    Commissioning Proline Promass I 300 PROFIBUS PA 10.6.5 Configuring the analog inputs The Analog inputs submenu guides the user systematically to the individual Analog input 1 to n submenu. From here you get to the parameters of the individual analog input.
  • Page 95 Proline Promass I 300 PROFIBUS PA Commissioning Parameter overview with brief description Parameter Prerequisite Description Selection / User Factory setting entry Channel – Select the process variable. • Mass flow Mass flow • Volume flow • Corrected volume flow • Density • Reference density •...
  • Page 96: I/O Configuration

    Commissioning Proline Promass I 300 PROFIBUS PA Parameter Prerequisite Description Selection / User Factory setting entry Fail safe type – Select the failure mode. • Fail-safe value • Fallback value • Off Fail-safe value In Fail safe type parameter, Specify the values to be output...
  • Page 97 Proline Promass I 300 PROFIBUS PA Commissioning 10.6.7 Configuring the current input The "Current input" wizard guides the user systematically through all the parameters that have to be set for configuring the current input. Navigation "Setup" menu → Current input ‣...
  • Page 98 Commissioning Proline Promass I 300 PROFIBUS PA 10.6.8 Configuring the status input The Status input submenu guides the user systematically through all the parameters that have to be set for configuring the status input. Navigation "Setup" menu → Status input ‣...
  • Page 99 Proline Promass I 300 PROFIBUS PA Commissioning Signal mode →  99 Assign current output 1 to n →  100 Current span →  100 0/4 mA value →  101 →  101 20 mA value Fixed current →...
  • Page 100 Commissioning Proline Promass I 300 PROFIBUS PA Parameter Prerequisite Description User interface /  Factory setting Selection / User entry Assign current output 1 to n – Select process variable for • Off Mass flow current output. • Mass flow • Volume flow • Corrected volume flow •...
  • Page 101 Proline Promass I 300 PROFIBUS PA Commissioning Parameter Prerequisite Description User interface /  Factory setting Selection / User entry 0/4 mA value One of the following options is Enter 4 mA value. Signed floating-point Country-specific: selected in the Current span number • 0 kg/h parameter (→...
  • Page 102: To N

    Commissioning Proline Promass I 300 PROFIBUS PA 10.6.10 Configuring the pulse/frequency/switch output The Pulse/frequency/switch output wizard guides you systematically through all the parameters that can be set for configuring the selected output type. Navigation "Setup" menu → Advanced setup → Pulse/frequency/switch output ‣...
  • Page 103 Proline Promass I 300 PROFIBUS PA Commissioning Parameter overview with brief description Parameter Prerequisite Description Selection / User Factory setting interface / User entry Operating mode – Define the output as a pulse, • Pulse Pulse frequency or switch output. • Frequency • Switch Terminal number –...
  • Page 104 Commissioning Proline Promass I 300 PROFIBUS PA Terminal number →  104 Signal mode →  104 Assign frequency output →  105 Minimum frequency value →  106 →  106 Maximum frequency value Measuring value at minimum →  106...
  • Page 105 Proline Promass I 300 PROFIBUS PA Commissioning Parameter Prerequisite Description Selection / User Factory setting interface / User entry Assign frequency output The Frequency option is Select process variable for • Off selected in the Operating frequency output. • Mass flow mode parameter (→  102) •...
  • Page 106 Commissioning Proline Promass I 300 PROFIBUS PA Parameter Prerequisite Description Selection / User Factory setting interface / User entry Minimum frequency value The Frequency option is Enter minimum frequency. 0.0 to 10 000.0 Hz 0.0 Hz selected in the Operating mode parameter (→  102)
  • Page 107 Proline Promass I 300 PROFIBUS PA Commissioning Configuring the switch output Navigation "Setup" menu → Pulse/frequency/switch output ‣ Pulse/frequency/switch output 1 to n Operating mode →  107 Terminal number →  107 Signal mode →  107 →  108...
  • Page 108 Commissioning Proline Promass I 300 PROFIBUS PA Parameter Prerequisite Description Selection / User Factory setting interface / User entry Switch output function The Switch option is selected Select function for switch • Off in the Operating mode output. • On parameter. • Diagnostic behavior •...
  • Page 109 Proline Promass I 300 PROFIBUS PA Commissioning Parameter Prerequisite Description Selection / User Factory setting interface / User entry Switch-on value • In the Operating mode Enter measured value for the Signed floating-point Country-specific: parameter, the Switch switch-on point. number • 0 kg/h option is selected.
  • Page 110: Relay Output 1 To N

    Commissioning Proline Promass I 300 PROFIBUS PA Switch-on value →  111 Failure mode →  111 Parameter overview with brief description Parameter Prerequisite Description Selection / User Factory setting interface / User entry Relay output function – Select the function for the • Closed Closed relay output.
  • Page 111 Proline Promass I 300 PROFIBUS PA Commissioning Parameter Prerequisite Description Selection / User Factory setting interface / User entry Assign status In the Relay output function Select device status for switch • Partially filled pipe Partially filled pipe parameter, the Digital Output output. detection detection option is selected.
  • Page 112 Commissioning Proline Promass I 300 PROFIBUS PA Parameter overview with brief description Parameter Prerequisite Description Selection / User Factory setting entry Format display A local display is provided. Select how measured values • 1 value, max. size 1 value, max. size are shown on the display.
  • Page 113 Proline Promass I 300 PROFIBUS PA Commissioning Parameter Prerequisite Description Selection / User Factory setting entry Value 1 display A local display is provided. Select the measured value that • Mass flow Mass flow is shown on the local display. • Volume flow •...
  • Page 114 Commissioning Proline Promass I 300 PROFIBUS PA Parameter Prerequisite Description Selection / User Factory setting entry 100% bargraph value 1 A local display is provided. Enter 100% value for bar Signed floating-point Depends on country graph display. number and nominal diameter Value 2 display A local display is provided.
  • Page 115 Proline Promass I 300 PROFIBUS PA Commissioning 10.6.13 Configuring the low flow cut off The Low flow cut off wizard systematically guides the user through all the parameters that must be set to configure low flow cut off. Navigation "Setup" menu → Low flow cut off ‣...
  • Page 116: Partially Filled Pipe Detection

    Commissioning Proline Promass I 300 PROFIBUS PA 10.6.14 Configuring the partial filled pipe detection The Partial filled pipe detection wizard guides you systematically through all parameters that have to be set for configuring the monitoring of the pipe filling. Navigation "Setup"...
  • Page 117: Advanced Setup

    Proline Promass I 300 PROFIBUS PA Commissioning 10.7 Advanced settings The Advanced setup submenu together with its submenus contains parameters for specific settings. Navigation to the "Advanced setup" submenu X X X X X X X 20.50 0104-1 Main menu...
  • Page 118 Commissioning Proline Promass I 300 PROFIBUS PA ‣ WLAN settings →  126 ‣ Viscosity ‣ Concentration ‣ Heartbeat setup ‣ →  127 Configuration backup ‣ Administration →  129 10.7.1 Calculated values The Calculated values submenu contains parameters for calculating the corrected volume flow.
  • Page 119 Proline Promass I 300 PROFIBUS PA Commissioning Parameter Prerequisite Description Selection / User Factory setting interface / User entry Fixed reference density The Fixed reference density Enter fixed value for reference Positive floating- 1 kg/Nl option is selected in the density. point number Corrected volume flow calculation parameter parameter.
  • Page 120 Commissioning Proline Promass I 300 PROFIBUS PA Navigation "Setup" menu → Advanced setup → Sensor adjustment → Zero point adjustment ‣ Zero point adjustment →  120 Zero point adjustment control →  120 Progress Parameter overview with brief description...
  • Page 121 Proline Promass I 300 PROFIBUS PA Commissioning Parameter overview with brief description Parameter Description Selection Factory setting Assign process variable Select process variable for totalizer. • Mass flow Mass flow • Volume flow • Corrected volume flow • Target mass flow •...
  • Page 122 Commissioning Proline Promass I 300 PROFIBUS PA 10.7.4 Carrying out additional display configurations In the Display submenu you can set all the parameters associated with the configuration of the local display. Navigation "Setup" menu → Advanced setup → Display ‣...
  • Page 123 Proline Promass I 300 PROFIBUS PA Commissioning Parameter overview with brief description Parameter Prerequisite Description Selection / User Factory setting entry Format display A local display is provided. Select how measured values • 1 value, max. size 1 value, max. size are shown on the display.
  • Page 124 Commissioning Proline Promass I 300 PROFIBUS PA Parameter Prerequisite Description Selection / User Factory setting entry Value 1 display A local display is provided. Select the measured value that • Mass flow Mass flow is shown on the local display. • Volume flow •...
  • Page 125 Proline Promass I 300 PROFIBUS PA Commissioning Parameter Prerequisite Description Selection / User Factory setting entry 100% bargraph value 1 A local display is provided. Enter 100% value for bar Signed floating-point Depends on country graph display. number and nominal diameter Decimal places 1...
  • Page 126 Commissioning Proline Promass I 300 PROFIBUS PA Parameter Prerequisite Description Selection / User Factory setting entry Display interval A local display is provided. Set time measured values are 1 to 10 s shown on display if display alternates between values. Display damping A local display is provided.
  • Page 127 Proline Promass I 300 PROFIBUS PA Commissioning Parameter overview with brief description Parameter Prerequisite Description User entry /  Factory setting Selection WLAN IP address – Enter IP address of the device 4 octet: 0 to 255 (in 192.168.1.212 WLAN interface. the particular octet) Network security –...
  • Page 128 Commissioning Proline Promass I 300 PROFIBUS PA Backup state →  128 Comparison result →  128 Parameter overview with brief description Parameter Description User interface / Selection Factory setting Operating time Indicates how long the device has been in Days (d), hours (h), minutes –...
  • Page 129 Proline Promass I 300 PROFIBUS PA Commissioning 10.7.7 Using parameters for device administration The Administration submenu systematically guides the user through all the parameters that can be used for device administration purposes. Navigation "Setup" menu → Advanced setup → Administration ‣...
  • Page 130 Commissioning Proline Promass I 300 PROFIBUS PA Parameter overview with brief description Parameter Description User interface / User entry Factory setting Operating time Indicates how long the device has been in Days (d), hours (h), minutes – operation. (m) and seconds (s) Reset access code Reset access code to factory settings.
  • Page 131 Proline Promass I 300 PROFIBUS PA Commissioning Current output 1 to n simulation →  132 Value current output 1 to n →  132 Frequency output simulation 1 to n →  132 Frequency value 1 to n →  132 Pulse output simulation 1 to n →...
  • Page 132 Commissioning Proline Promass I 300 PROFIBUS PA Parameter overview with brief description Parameter Prerequisite Description Selection / User Factory setting entry / User interface Assign simulation process variable – Select a process variable for • Off the simulation process that is • Mass flow activated.
  • Page 133 Proline Promass I 300 PROFIBUS PA Commissioning Parameter Prerequisite Description Selection / User Factory setting entry / User interface Pulse output simulation 1 to n In the Operating mode Set and switch off the pulse • Off parameter, the Pulse option is output simulation.
  • Page 134 Commissioning Proline Promass I 300 PROFIBUS PA 10.9 Protecting settings from unauthorized access The following write protection options exist in order to protect the configuration of the measuring device from unintentional modification: • Protect access to parameters via access code →  134 •...
  • Page 135 Via Web browser, FieldCare, DeviceCare (via CDI-RJ45 service interface), fieldbus For a reset code, contact your Endress+Hauser service organization. 1. Navigate to the Reset access code parameter (→  130). 2. Enter the reset code.
  • Page 136 Commissioning Proline Promass I 300 PROFIBUS PA A0029630 Setting the write protection (WP) switch on the main electronics module to the ON position enables hardware write protection.  In the Locking status parameter the Hardware locked option is displayed →  137. In addition, on the local display the -symbol appears in front of the parameters in the header of the operational display and in the navigation view.
  • Page 137 Proline Promass I 300 PROFIBUS PA Operation Operation 11.1 Reading the device locking status Device active write protection: Locking status parameter Operation → Locking status Function scope of the "Locking status" parameter Options Description None The access status displayed in the Access status parameter applies →  59. Only appears on local display.
  • Page 138 Operation Proline Promass I 300 PROFIBUS PA 11.4.1 "Measured variables" submenu The Measured variables submenu contains all the parameters needed to display the current measured values for each process variable. Navigation "Diagnostics" menu → Measured values → Measured variables ‣...
  • Page 139 Proline Promass I 300 PROFIBUS PA Operation Parameter Prerequisite Description User interface Corrected volume flow – Displays the corrected volume flow Signed floating-point currently calculated. number Dependency The unit is taken from the Corrected volume flow unit parameter (→  89).
  • Page 140 Operation Proline Promass I 300 PROFIBUS PA Parameter Prerequisite Description User interface Concentration For the following order code: Displays the concentration currently Signed floating-point Order code for "Application package", calculated. number option ED "Concentration" Dependency  The software options currently...
  • Page 141 Proline Promass I 300 PROFIBUS PA Operation Parameter overview with brief description Parameter Prerequisite Description Selection / User Factory setting entry / User interface Assign process variable – Select process variable for • Mass flow Mass flow totalizer. • Volume flow • Corrected volume flow •...
  • Page 142 Operation Proline Promass I 300 PROFIBUS PA Navigation "Diagnostics" menu → Measured values → Input values → Current input 1 to n ‣ Current input 1 to n →  142 Measured values 1 to n →  142 Measured current 1 to n...
  • Page 143 Proline Promass I 300 PROFIBUS PA Operation ‣ Pulse/frequency/switch output →  143 1 to n ‣ Relay output 1 to n →  144 Output values of current output The Value current output submenu contains all the parameters needed to display the current measured values for every current output.
  • Page 144 Operation Proline Promass I 300 PROFIBUS PA Parameter overview with brief description Parameter Prerequisite Description User interface Output frequency 1 to n In the Operating mode parameter, the Displays the value currently measured 0.0 to 12 500.0 Hz Frequency option is selected.
  • Page 145 Proline Promass I 300 PROFIBUS PA Operation Function scope of the "Control Totalizer " parameter Options Description Totalize The totalizer is started. Reset + hold The totaling process is stopped and the totalizer is reset to 0. Preset + hold The totaling process is stopped and the totalizer is set to its defined start value from the Preset value 1 to n parameter.
  • Page 146 Operation Proline Promass I 300 PROFIBUS PA / ../XXXXXXXX 175.77 40.69 kg/h -100s A0016357  25 Chart of a measured value trend • x-axis: depending on the number of channels selected displays 250 to 1000 measured values of a process variable.
  • Page 147 Proline Promass I 300 PROFIBUS PA Operation Parameter overview with brief description Parameter Prerequisite Description Selection / User Factory setting entry / User interface Assign channel 1 The Extended HistoROM Assign process variable to • Off application package is logging channel. • Mass flow available.
  • Page 148 Operation Proline Promass I 300 PROFIBUS PA Parameter Prerequisite Description Selection / User Factory setting entry / User interface Assign channel 2 The Extended HistoROM Assign process variable to Picklist, see Assign application package is logging channel. channel 1 parameter available. (→  147) ...
  • Page 149 Proline Promass I 300 PROFIBUS PA Diagnostics and troubleshooting Diagnostics and troubleshooting 12.1 General troubleshooting For local display Error Possible causes Solution Local display dark and no output Supply voltage does not match the Apply the correct supply voltage signals value indicated on the nameplate.
  • Page 150 Diagnostics and troubleshooting Proline Promass I 300 PROFIBUS PA For access Error Possible causes Solution No write access to parameters Hardware write protection enabled Set the write protection switch on main electronics module to the OFF position →  135.
  • Page 151 Proline Promass I 300 PROFIBUS PA Diagnostics and troubleshooting Error Possible causes Solution No or incomplete display of • JavaScript not enabled 1. Enable JavaScript. contents in the Web browser • JavaScript cannot be enabled 2. Enter http://XXX.XXX.X.XXX/ basic.html as the IP address.
  • Page 152 Diagnostics and troubleshooting Proline Promass I 300 PROFIBUS PA 12.2 Diagnostic information via light emitting diodes 12.2.1 Transmitter Different LEDs in the transmitter provide information on the device status. 1 2 3 4 5 A0029629 Supply voltage Device status Not used...
  • Page 153 Proline Promass I 300 PROFIBUS PA Diagnostics and troubleshooting 12.3 Diagnostic information on local display 12.3.1 Diagnostic message Faults detected by the self-monitoring system of the measuring device are displayed as a diagnostic message in alternation with the operational display.
  • Page 154 Diagnostics and troubleshooting Proline Promass I 300 PROFIBUS PA Diagnostic behavior Symbol Meaning Alarm • Measurement is interrupted. • Signal outputs and totalizers assume the defined alarm condition. • A diagnostic message is generated. Warning Measurement is resumed. The signal outputs and totalizers are not affected. A diagnostic message is generated.
  • Page 155 Proline Promass I 300 PROFIBUS PA Diagnostics and troubleshooting 12.3.2 Calling up remedial measures X X X X X X X X X X X X X X 20.50 S801 Supply voltage Menu Diagnostic list Diagnostics 1 S801 Supply voltage...
  • Page 156 Diagnostics and troubleshooting Proline Promass I 300 PROFIBUS PA A0031056 Status area with status signal Diagnostic information→  154 Remedy information with Service ID In addition, diagnostic events which have occurred can be shown in the Diagnostics menu: • Via parameter •...
  • Page 157 Proline Promass I 300 PROFIBUS PA Diagnostics and troubleshooting Xxxxxx/…/…/ Device name: Xxxxxxx Mass flow: kg/h 12.34 Device tag: Xxxxxxx Volume flow: 12.34 m /h ³ Status signal: Function check (C) Xxxxxx Diagnostics 1: C485 Simu... Remedy information: Deactivate... Failure (F)
  • Page 158 Diagnostics and troubleshooting Proline Promass I 300 PROFIBUS PA The user is in the Diagnostics menu. 1. Call up the desired parameter. 2. On the right in the working area, mouse over the parameter.  A tool tip with remedy information for the diagnostic event appears.
  • Page 159 Proline Promass I 300 PROFIBUS PA Diagnostics and troubleshooting Coding Measuring value (hex) Byte 5 Quality Quality Substatus Limits A0032228-EN  27 Structure of the coding byte The content of the coding byte depends on the configured failsafe mode in the particular function block.
  • Page 160 Diagnostics and troubleshooting Proline Promass I 300 PROFIBUS PA Diagnostic information pertaining to the electronics: diagnostic number 200 to 399 Diagnostic number 200 to 301, 303 to 399 Measured value status (fixed assignment) Diagnostic behavior Device diagnosis Quality Coding Category...
  • Page 161 Proline Promass I 300 PROFIBUS PA Diagnostics and troubleshooting Measured value status (fixed assignment) Diagnostic behavior Device diagnosis Quality Coding Category (configurable) (fixed assignment) Quality Substatus (hex) (NE107) Logbook entry only GOOD 0x80 to 0x8E – – 12.7 Overview of diagnostic information •...
  • Page 162 Diagnostics and troubleshooting Proline Promass I 300 PROFIBUS PA Diagnostic information Remedy instructions Short text 046 Sensor limit exceeded 1. Inspect sensor 2. Check process condition Measured variable status [from the factory] Quality Good Quality substatus Maintenance demanded Coding (hex)
  • Page 163 Proline Promass I 300 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 062 Sensor connection faulty 1. Check or replace sensor electronic module (ISEM) 2. If available: Check connection cable between sensor and transmitter Measured variable status 3.
  • Page 164 Diagnostics and troubleshooting Proline Promass I 300 PROFIBUS PA Diagnostic information Remedy instructions Short text 063 Exciter current faulty 1. Check or replace sensor electronic module (ISEM) 2. If available: Check connection cable between sensor and transmitter Measured variable status 3.
  • Page 165 Proline Promass I 300 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 082 Data storage 1. Check module connections 2. Contact service Measured variable status Quality Quality substatus Maintenance alarm Coding (hex) 0x24 to 0x27 Status signal...
  • Page 166 Diagnostics and troubleshooting Proline Promass I 300 PROFIBUS PA Diagnostic information Remedy instructions Short text 083 Memory content 1. Restart device 2. Restore HistoROM S-DAT backup (' D evice reset' parameter) Measured variable status 3. Replace HistoROM S-DAT Quality Quality substatus...
  • Page 167 Proline Promass I 300 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 140 Sensor signal asymmetrical 1. Check or replace sensor electronic module (ISEM) 2. If available: Check connection cable between sensor and transmitter Measured variable status [from the factory] 3.
  • Page 168 Diagnostics and troubleshooting Proline Promass I 300 PROFIBUS PA Diagnostic information Remedy instructions Short text 144 Measuring error too high 1. Check or change sensor 2. Check process conditions Measured variable status [from the factory] Quality Quality substatus Maintenance alarm...
  • Page 169 Proline Promass I 300 PROFIBUS PA Diagnostics and troubleshooting 12.7.2 Diagnostic of electronic Diagnostic information Remedy instructions Short text 201 Device failure 1. Restart device 2. Contact service Measured variable status Quality Quality substatus Maintenance alarm Coding (hex) 0x24 to 0x27...
  • Page 170 Diagnostics and troubleshooting Proline Promass I 300 PROFIBUS PA Diagnostic information Remedy instructions Short text 242 Software incompatible 1. Check software 2. Flash or change main electronics module Measured variable status Quality Quality substatus Maintenance alarm Coding (hex) 0x24 to 0x27...
  • Page 171 Proline Promass I 300 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 252 Modules incompatible 1. Check electronic modules 2. Check if correct modules are available (e.g. NEx, Ex) Measured variable status 3. Replace electronic modules Quality...
  • Page 172 Diagnostics and troubleshooting Proline Promass I 300 PROFIBUS PA Diagnostic information Remedy instructions Short text 262 Sensor electronic connection faulty 1. Check or replace connection cable between sensor electronic module (ISEM) and main electronics Measured variable status 2. Check or replace ISEM or main electronics...
  • Page 173 Proline Promass I 300 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 270 Main electronic failure Change main electronic module Measured variable status Quality Quality substatus Maintenance alarm Coding (hex) 0x24 to 0x27 Status signal Diagnostic behavior...
  • Page 174 Diagnostics and troubleshooting Proline Promass I 300 PROFIBUS PA Diagnostic information Remedy instructions Short text 271 Main electronic failure 1. Restart device 2. Change main electronic module Measured variable status Quality Quality substatus Maintenance alarm Coding (hex) 0x24 to 0x27...
  • Page 175 Proline Promass I 300 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 272 Main electronic failure 1. Restart device 2. Contact service Measured variable status Quality Quality substatus Maintenance alarm Coding (hex) 0x24 to 0x27 Status signal...
  • Page 176 Diagnostics and troubleshooting Proline Promass I 300 PROFIBUS PA Diagnostic information Remedy instructions Short text 273 Main electronic failure Change electronic Measured variable status Quality Quality substatus Maintenance alarm Coding (hex) 0x24 to 0x27 Status signal Diagnostic behavior Alarm Influenced measured variables •...
  • Page 177 Proline Promass I 300 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 276 I/O module 1 to n faulty 1. Restart device 2. Change I/O module Measured variable status Quality Quality substatus Maintenance alarm Coding (hex) 0x24 to 0x27...
  • Page 178 Diagnostics and troubleshooting Proline Promass I 300 PROFIBUS PA Diagnostic information Remedy instructions Short text 302 Device verification active Device verification active, please wait. Measured variable status [from the factory] Quality Good Quality substatus Function check Coding (hex) 0xBC to 0xBF...
  • Page 179 Proline Promass I 300 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 311 Electronic failure 1. Do not reset device 2. Contact service Measured variable status Quality Quality substatus Maintenance alarm Coding (hex) 0x24 to 0x27 Status signal...
  • Page 180 Diagnostics and troubleshooting Proline Promass I 300 PROFIBUS PA Diagnostic information Remedy instructions Short text 332 Writing in HistoROM backup failed Replace user interface board Ex d/XP: replace transmitter Measured variable status Quality Quality substatus Maintenance alarm Coding (hex) 0x24 to 0x27...
  • Page 181 Proline Promass I 300 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 372 Sensor electronic (ISEM) faulty 1. Restart device 2. Check if failure recurs Measured variable status 3. Replace sensor electronic module (ISEM) Quality Quality substatus...
  • Page 182 Diagnostics and troubleshooting Proline Promass I 300 PROFIBUS PA Diagnostic information Remedy instructions Short text 373 Sensor electronic (ISEM) faulty 1. Transfer data or reset device 2. Contact service Measured variable status Quality Quality substatus Maintenance alarm Coding (hex) 0x24 to 0x27...
  • Page 183 Proline Promass I 300 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 375 I/O- 1 to n communication failed 1. Restart device 2. Check if failure recurs Measured variable status 3. Replace module rack inclusive electronic modules...
  • Page 184 Diagnostics and troubleshooting Proline Promass I 300 PROFIBUS PA Diagnostic information Remedy instructions Short text 382 Data storage 1. Insert T-DAT 2. Replace T-DAT Measured variable status Quality Quality substatus Maintenance alarm Coding (hex) 0x24 to 0x27 Status signal Diagnostic behavior...
  • Page 185 Proline Promass I 300 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 383 Memory content 1. Restart device 2. Delete T-DAT via ' R eset device' parameter Measured variable status 3. Replace T-DAT Quality Quality substatus Maintenance alarm...
  • Page 186 Diagnostics and troubleshooting Proline Promass I 300 PROFIBUS PA Diagnostic information Remedy instructions Short text 387 HistoROM backup failed Contact service organization Measured variable status Quality Quality substatus Maintenance alarm Coding (hex) 0x24 to 0x27 Status signal Diagnostic behavior Alarm Influenced measured variables •...
  • Page 187 Proline Promass I 300 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 331 Firmware update failed 1. Update firmware of device 2. Restart device Measured variable status Quality Quality substatus Maintenance alarm Coding (hex) 0x24 to 0x27...
  • Page 188 Diagnostics and troubleshooting Proline Promass I 300 PROFIBUS PA Diagnostic information Remedy instructions Short text 410 Data transfer 1. Check connection 2. Retry data transfer Measured variable status Quality Quality substatus Maintenance alarm Coding (hex) 0x24 to 0x27 Status signal...
  • Page 189 Proline Promass I 300 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 412 Processing download Download active, please wait Measured variable status Quality Uncertain Quality substatus Initial value Coding (hex) 0x4C to 0x4F Status signal Diagnostic behavior...
  • Page 190 Diagnostics and troubleshooting Proline Promass I 300 PROFIBUS PA Diagnostic information Remedy instructions Short text 437 Configuration incompatible 1. Restart device 2. Contact service Measured variable status Quality Quality substatus Maintenance alarm Coding (hex) 0x24 to 0x27 Status signal Diagnostic behavior...
  • Page 191 Proline Promass I 300 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 438 Dataset 1. Check data set file 2. Check device configuration Measured variable status 3. Up- and download new configuration Quality Uncertain Quality substatus Maintenance demanded...
  • Page 192 Diagnostics and troubleshooting Proline Promass I 300 PROFIBUS PA Diagnostic information Remedy instructions Short text 442 Frequency output 1 to n 1. Check process 2. Check frequency output settings Measured variable status [from the factory] Quality Good Quality substatus Function check...
  • Page 193 Proline Promass I 300 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 453 Flow override Deactivate flow override Measured variable status Quality Good Quality substatus Function check Coding (hex) 0xBC to 0xBF Status signal Diagnostic behavior Warning Influenced measured variables •...
  • Page 194 Diagnostics and troubleshooting Proline Promass I 300 PROFIBUS PA Diagnostic information Remedy instructions Short text 482 FB not Auto/Cas Set Block in AUTO mode Measured variable status Quality Good Quality substatus Coding (hex) 0x80 to 0x83 Status signal Diagnostic behavior...
  • Page 195 Proline Promass I 300 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 485 Measured variable simulation Deactivate simulation Measured variable status Quality Good Quality substatus Function check Coding (hex) 0xBC to 0xBF Status signal Diagnostic behavior Warning Influenced measured variables •...
  • Page 196 Diagnostics and troubleshooting Proline Promass I 300 PROFIBUS PA Diagnostic information Remedy instructions Short text 491 Current output 1 to n simulation Deactivate simulation Measured variable status Quality Good Quality substatus Function check Coding (hex) 0xBC to 0xBF Status signal...
  • Page 197 Proline Promass I 300 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 494 Switch output simulation 1 to n Deactivate simulation switch output Measured variable status Quality Good Quality substatus Function check Coding (hex) 0xBC to 0xBF...
  • Page 198 Diagnostics and troubleshooting Proline Promass I 300 PROFIBUS PA Diagnostic information Remedy instructions Short text 497 Simulation block output Deactivate simulation Measured variable status Quality Good Quality substatus Coding (hex) 0x80 to 0x83 Status signal Diagnostic behavior Warning Influenced measured variables –...
  • Page 199 Proline Promass I 300 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 529 Concentration settings faulty 1. Check concentration settings 2. Check input values e.g. pressure, temperature Measured variable status Quality Quality substatus Function check Coding (hex)
  • Page 200 Diagnostics and troubleshooting Proline Promass I 300 PROFIBUS PA 12.7.4 Diagnostic of process Diagnostic information Remedy instructions Short text 803 Current loop 1. Check wiring 2. Change I/O module Measured variable status Quality Quality substatus Process related Coding (hex) 0x28 to 0x2B...
  • Page 201 Proline Promass I 300 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 831 Sensor temperature too low Increase ambient temp. around the sensor housing Measured variable status [from the factory] Quality Uncertain Quality substatus Process related Coding (hex)
  • Page 202 Diagnostics and troubleshooting Proline Promass I 300 PROFIBUS PA Diagnostic information Remedy instructions Short text 832 Electronic temperature too high Reduce ambient temperature Measured variable status [from the factory] Quality Quality substatus Process related Coding (hex) 0x28 to 0x2B Status signal...
  • Page 203 Proline Promass I 300 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 833 Electronic temperature too low Increase ambient temperature Measured variable status [from the factory] Quality Quality substatus Process related Coding (hex) 0x28 to 0x2B Status signal...
  • Page 204 Diagnostics and troubleshooting Proline Promass I 300 PROFIBUS PA Diagnostic information Remedy instructions Short text 834 Process temperature too high Reduce process temperature Measured variable status [from the factory] Quality Uncertain Quality substatus Process related Coding (hex) 0x78 to 0x7B...
  • Page 205 Proline Promass I 300 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 835 Process temperature too low Increase process temperature Measured variable status [from the factory] Quality Uncertain Quality substatus Process related Coding (hex) 0x78 to 0x7B...
  • Page 206 Diagnostics and troubleshooting Proline Promass I 300 PROFIBUS PA Diagnostic information Remedy instructions Short text 842 Process limit Low flow cut off active! 1. Check low flow cut off configuration Measured variable status [from the factory] Quality Uncertain Quality substatus...
  • Page 207 Proline Promass I 300 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 882 Input signal 1. Check input configuration 2. Check external device or process conditions Measured variable status Quality Quality substatus Maintenance alarm Coding (hex) 0x24 to 0x27...
  • Page 208 Diagnostics and troubleshooting Proline Promass I 300 PROFIBUS PA Diagnostic information Remedy instructions Short text 910 Tubes not oscillating 1. Check electronic 2. Inspect sensor Measured variable status Quality Quality substatus Maintenance alarm Coding (hex) 0x24 to 0x27 Status signal...
  • Page 209 Proline Promass I 300 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 912 Medium inhomogeneous 1. Check process cond. 2. Increase system pressure Measured variable status [from the factory] Quality Uncertain Quality substatus Process related Coding (hex)
  • Page 210 Diagnostics and troubleshooting Proline Promass I 300 PROFIBUS PA Diagnostic information Remedy instructions Short text 913 Medium unsuitable 1. Check process conditions 2. Check electronic modules or sensor Measured variable status [from the factory] Quality Uncertain Quality substatus Process related...
  • Page 211 Proline Promass I 300 PROFIBUS PA Diagnostics and troubleshooting Diagnostic information Remedy instructions Short text 942 API density out of specification 1. Check process density with selected API commodity group 2. Check API related parameters Measured variable status Quality Quality substatus...
  • Page 212 Diagnostics and troubleshooting Proline Promass I 300 PROFIBUS PA Diagnostic information Remedy instructions Short text 944 Monitoring failed Check process conditions for Heartbeat Monitoring Measured variable status [from the factory] Quality Quality substatus Maintenance alarm Coding (hex) 0x24 to 0x27...
  • Page 213 Proline Promass I 300 PROFIBUS PA Diagnostics and troubleshooting 12.8 Pending diagnostic events The Diagnostics menu allows the user to view the current diagnostic event and the previous diagnostic event separately. To call up the measures to rectify a diagnostic event: •...
  • Page 214 Diagnostics and troubleshooting Proline Promass I 300 PROFIBUS PA / ../Diagnose list Diagnostics F273 Main electronic Diagnostics 2 Diagnostics 3 A0014006-EN  28 Taking the example of the local display To call up the measures to rectify a diagnostic event: •...
  • Page 215 Proline Promass I 300 PROFIBUS PA Diagnostics and troubleshooting 12.10.2 Filtering the event logbook Using the Filter options parameter you can define which category of event message is displayed in the Events list submenu. Navigation path Diagnostics → Event logbook → Filter options Filter categories •...
  • Page 216 Diagnostics and troubleshooting Proline Promass I 300 PROFIBUS PA Info number Info name I1451 Monitoring on I1457 Measured error verification failed I1459 I/O module verification failed I1460 HBSI verification failed I1461 Sensor verification failed I1462 Sensor electronic module verific. failed...
  • Page 217 Proline Promass I 300 PROFIBUS PA Diagnostics and troubleshooting 12.11.1 Function scope of the "Device reset" parameter Options Description Cancel No action is executed and the user exits the parameter. To delivery settings Every parameter for which a customer-specific default setting was ordered is reset to this customer-specific value.
  • Page 218 Diagnostics and troubleshooting Proline Promass I 300 PROFIBUS PA Parameter overview with brief description Parameter Description User interface Factory setting Device tag Shows name of measuring point. Max. 32 characters, such as Promass 300 PA letters, numbers or special characters (e.g. @, %, /).
  • Page 219 "Manufacturer' s information" document. The manufacturer' s information is available: • In the Download Area of the Endress+Hauser web site: www.endress.com → Downloads • Specify the following details: –...
  • Page 220 Observe the inside diameter of the measuring tube and process connection. 13.2 Measuring and test equipment Endress+Hauser offers a wide variety of measuring and test equipment, such as W@M or device tests. Your Endress+Hauser Sales Center can provide detailed information on the services.
  • Page 221 • The measuring devices have a modular design. • Spare parts are grouped into logical kits with the associated Installation Instructions. • Repairs are carried out by Endress+Hauser Service or by appropriately trained customers. • Certified devices can only be converted to other certified devices by Endress+Hauser Service or at the factory.
  • Page 222 Repairs Proline Promass I 300 PROFIBUS PA 14.5 Disposal 14.5.1 Removing the measuring device 1. Switch off the device. WARNING Danger to persons from process conditions. ‣ Beware of hazardous process conditions such as pressure in the measuring device, high temperatures or aggressive fluids.
  • Page 223 Various accessories, which can be ordered with the device or subsequently from Endress +Hauser, are available for the device. Detailed information on the order code in question is available from your local Endress+Hauser sales center or on the product page of the Endress+Hauser website: www.endress.com.
  • Page 224 Is used to stabilize the temperature of the fluids in the sensor. Water, water vapor and other non-corrosive liquids are permitted for use as fluids.  If using oil as a heating medium, please consult with Endress+Hauser. • If ordered together with the measuring device: order code for "Enclosed accessories"...
  • Page 225 Proline Promass I 300 PROFIBUS PA Accessories 15.3 System components Accessories Description Memograph M graphic The Memograph M graphic data manager provides information on all the relevant data manager measured variables. Measured values are recorded correctly, limit values are monitored and measuring points analyzed. The data are stored in the 256 MB internal memory and also on a SD card or USB stick.
  • Page 226 Technical data Proline Promass I 300 PROFIBUS PA Technical data 16.1 Application The measuring device is suitable for flow measurement of liquids and gases only. Depending on the version ordered, the measuring device can also measure potentially explosive, flammable, poisonous and oxidizing media.
  • Page 227 Proline Promass I 300 PROFIBUS PA Technical data 16.3 Input Measured variable Direct measured variables • Mass flow • Density • Temperature • Viscosity Calculated measured variables • Volume flow • Corrected volume flow • Reference density Measuring range Measuring range for liquids Measuring range full scale values ...
  • Page 228 • Operating pressure to increase accuracy (Endress+Hauser recommends the use of a pressure measuring device for absolute pressure, e.g. Cerabar M or Cerabar S) •...
  • Page 229 Proline Promass I 300 PROFIBUS PA Technical data Current input 0/4 to 20 mA Current input 0/4 to 20 mA (active/passive) Current span • 4 to 20 mA (active) • 0/4 to 20 mA (passive) Resolution 1 µA Voltage drop Typically: 0.6 to 2 V for 3.6 to 22 mA (passive)
  • Page 230 Technical data Proline Promass I 300 PROFIBUS PA 16.4 Output Output signal PROFIBUS PA PROFIBUS PA In accordance with EN 50170 Volume 2, IEC 61158-2 (MBP), galvanically isolated Data transmission 31.25 kbit/s Current consumption 10 mA Permitted supply voltage 9 to 32 V...
  • Page 231 Proline Promass I 300 PROFIBUS PA Technical data Maximum input values DC 30 V, 250 mA (passive) Maximum output current 22.5 mA (active) Open-circuit voltage DC 28.8 V (active) Pulse width Adjustable: 0.05 to 2 000 ms Maximum pulse rate...
  • Page 232 Technical data Proline Promass I 300 PROFIBUS PA Relay output Function Switch output Version Relay output, galvanically isolated Switching behavior Can be set to: • NO (normally open), factory setting • NC (normally closed) Maximum switching • DC 30 V, 0.1 A capacity (passive) •...
  • Page 233 Proline Promass I 300 PROFIBUS PA Technical data Current output 0/4 to 20 mA 4 to 20 mA Failure mode Choose from: • 4 to 20 mA in accordance with NAMUR recommendation NE 43 • 4 to 20 mA in accordance with US •...
  • Page 234 Technical data Proline Promass I 300 PROFIBUS PA Interface/protocol • Via digital communication: PROFIBUS PA • Via service interface – CDI-RJ45 service interface – WLAN interface Plain text display With information on cause and remedial measures Web server Plain text display...
  • Page 235 Proline Promass I 300 PROFIBUS PA Technical data Compatibility with If the device is replaced, the measuring device Promass 300 supports the earlier model compatibility of the cyclic data with previous models. It is not necessary to adjust the engineering parameters of the PROFIBUS network with the Promass 300 GSD file.
  • Page 236 Technical data Proline Promass I 300 PROFIBUS PA terminals Spring-loaded terminals: Suitable for strands and strands with ferrules. Conductor cross-section 0.2 to 2.5 mm (24 to 12 AWG). Cable entries • Cable gland: M20 × 1.5 with cable ⌀ 6 to 12 mm (0.24 to 0.47 in) •...
  • Page 237 Proline Promass I 300 PROFIBUS PA Technical data Zero point stability Zero point stability [mm] [in] [kg/h] [lb/min] ³⁄₈ 0.150 0.0055 ½ 0.488 0.0179 15 FB ½ FB 1.350 0.0496 1.350 0.0496 25 FB 1 FB 3.375 0.124 1½ 3.375 0.124...
  • Page 238 Technical data Proline Promass I 300 PROFIBUS PA 1:10 1:20 1:50 1:100 1:500 [inch] [lb/min] [lb/min] [lb/min] [lb/min] [lb/min] [lb/min] 1½ FB 2 573 257.3 128.7 51.46 25.73 5.146 2 573 257.3 128.7 51.46 25.73 5.146 2 FB 6 615 661.5...
  • Page 239 Proline Promass I 300 PROFIBUS PA Technical data Influence of medium Mass flow and volume flow temperature o.f.s. = of full scale value When there is a difference between the temperature for zero point adjustment and the process temperature, the additional measured error of the sensor is typically ±0.0002 % o.f.s./°C (±0.0001 % o.
  • Page 240 Technical data Proline Promass I 300 PROFIBUS PA [% o.r./bar] [% o.r./psi] [mm] [in] 25 FB 1 FB No effect No effect 1½ No effect No effect 40 FB 1½ FB No effect No effect No effect No effect 50 FB...
  • Page 241 Proline Promass I 300 PROFIBUS PA Technical data 16.8 Environment Ambient temperature →  24 range Temperature tables Observe the interdependencies between the permitted ambient and fluid temperatures when operating the device in hazardous areas. For detailed information on the temperature tables, see the separate document entitled "Safety Instructions"...
  • Page 242 Technical data Proline Promass I 300 PROFIBUS PA Dependency of ambient temperature on medium temperature A0031121  30 Exemplary representation, values in the table below. Ambient temperature Medium temperature Maximum permitted medium temperature T at T = 60 °C (140 °F); higher medium temperatures T...
  • Page 243 Proline Promass I 300 PROFIBUS PA Technical data The following sensor housing nominal pressure ratings/burst pressures are only valid for standard devices and/or devices equipped with closed purge connections (not opened/as delivered). If a device fitted with purge connections (order code for "Sensor option", option CH "Purge connection") is connected to the purge system, the maximum nominal pressure is...
  • Page 244 Technical data Proline Promass I 300 PROFIBUS PA System pressure →  24 16.10 Mechanical construction Design, dimensions For the dimensions and installation lengths of the device, see the "Technical Information" document, "Mechanical construction" section. Weight All values (weight exclusive of packaging material) refer to devices with EN/DIN PN 40 flanges.
  • Page 245 Proline Promass I 300 PROFIBUS PA Technical data Weight [lbs] [in] FB = Full bore Materials Transmitter housing Order code for "Housing": • Option A "Aluminum, coated": aluminum, AlSi10Mg, coated • Option B "Stainless, hygienic": stainless steel, 1.4404 (316L) • Option L "Cast, stainless": cast, stainless steel, 1.4409 (CF3M) similar to 316L Window material Order code for "Housing":...
  • Page 246 Technical data Proline Promass I 300 PROFIBUS PA Order code for "Housing", option B "Stainless, hygienic" The various cable entries are suitable for hazardous and non-hazardous areas. Cable entry/cable gland Material Cable gland M20 × 1.5 Plastic Adapter for cable entry with internal thread G ½"...
  • Page 247 Proline Promass I 300 PROFIBUS PA Technical data External WLAN antenna • Antenna: ASA plastic (acrylic ester-styrene-acrylonitrile) and nickel-plated brass • Adapter: Stainless steel and nickel-plated brass • Cable: Polyethylene • Plug: Nickel-plated brass • Angle bracket: Stainless steel Process connections •...
  • Page 248 Technical data Proline Promass I 300 PROFIBUS PA A0026785  32 Operation with touch control Display elements • 4-line, illuminated, graphic display • White background lighting; switches to red in event of device errors • Format for displaying measured variables and status variables can be individually configured •...
  • Page 249 Proline Promass I 300 PROFIBUS PA Technical data Material The housing material of the display and operating module DKX001 depends on the choice of transmitter housing material. Transmitter housing Remote display and operating module Order code for "Housing" Material Material Option A "Aluminum, coated"...
  • Page 250 Technical data Proline Promass I 300 PROFIBUS PA Supported operating Operating unit Interface Additional information tools Web browser Notebook, PC or tablet • CDI-RJ45 service Special Documentation for with Web browser interface device →  257 • WLAN interface DeviceCare SFE100 Notebook, PC or tablet •...
  • Page 251 Proline Promass I 300 PROFIBUS PA Technical data HistoROM The measuring device features HistoROM data management. HistoROM data management data management comprises both the storage and import/export of key device and process data, making operation and servicing far more reliable, secure and efficient.
  • Page 252 The device meets the legal requirements of the applicable EU Directives. These are listed in the corresponding EU Declaration of Conformity along with the standards applied. Endress+Hauser confirms successful testing of the device by affixing to it the CE mark. C-Tick symbol The measuring system meets the EMC requirements of the "Australian Communications...
  • Page 253 • With the identification PED/G1/x (x = category) on the sensor nameplate, Directive Endress+Hauser confirms conformity with the "Essential Safety Requirements" specified in Appendix I of the Pressure Equipment Directive 2014/68/EU. • Devices not bearing this marking (PED) are designed and manufactured according to good engineering practice.
  • Page 254 The application packages can be ordered with the device or subsequently from Endress+Hauser. Detailed information on the order code in question is available from your local Endress+Hauser sales center or on the product page of the Endress+Hauser website: www.endress.com.
  • Page 255 Proline Promass I 300 PROFIBUS PA Technical data Heartbeat Technology Package Description Heartbeat Verification Heartbeat Verification +Monitoring Meets the requirement for traceable verification to DIN ISO 9001:2008 Chapter 7.6 a) "Control of monitoring and measuring equipment". • Functional testing in the installed state without interrupting the process.
  • Page 256 For an overview of the scope of the associated Technical Documentation, refer to the following: • W@M Device Viewer (www.endress.com/deviceviewer): Enter the serial number from nameplate • Endress+Hauser Operations App: Enter the serial number from the nameplate or scan the 2D matrix code (QR code) on the nameplate Standard documentation Brief Operating Instructions...
  • Page 257 Proline Promass I 300 PROFIBUS PA Technical data Remote display and operating module DKX001 Contents Documentation code ATEX/IECEx Ex i XA01494D ATEX/IECEx Ex ec XA01498D cCSAus IS XA01499D cCSAus Ex nA XA01513D INMETRO Ex i XA01500D INMETRO Ex ec XA01501D...
  • Page 258 Index Proline Promass I 300 PROFIBUS PA Index 0 … 9 Closing ....... . . 55 Explanation .
  • Page 259 Proline Promass I 300 PROFIBUS PA Index In the navigation view ..... 52 Version ....... . 73 Display values Firmware history .
  • Page 260 Index Proline Promass I 300 PROFIBUS PA Transmitter ......17 Navigation path (navigation view) ....51 Main electronics module .
  • Page 261 Proline Promass I 300 PROFIBUS PA Index Pulse/frequency/switch output (Wizard) 102, Return ........221...
  • Page 262 Index Proline Promass I 300 PROFIBUS PA Storage temperature range ....241 System pressure ......24 Structure Measuring device .
  • Page 263 Proline Promass I 300 PROFIBUS PA Index Wizard Current input ......97 Current output ......98 Define access code .
  • Page 264 www.addresses.endress.com...

Table of Contents