Toshiba MMU-UP0051MH-E(TR) Service Manual page 173

Table of Contents

Advertisement

No. Part name
1. Detachment
PMV coil
(1) Following to works of 1 of
the parts
(2) Cut the binding band to remove the tube on the relay
connector for the PMV lead wire.
(3) Remove the relay lead wire for PMV.
(4) Turn the PMV coil slightly while holding the PMV body
so that the body does not turn, and remove the PMV
coil in the arrow direction.
2. Attachment
(1) Attach the PMV coil as before
NOTE
• Check the direction of the PMV coil.
• Check the PMV coil protrusion part points to the PMV
body inlet.
• Check the claw holes in the PMV coil are securely placed
into four claws on the PMV body.
(2) Connect relay lead wire for PMV to lead wire for PMV
coli.
(3) Wrap the connector of relay lead wire for PMV with the
protective tube and fix them with the binding band.
NOTE
Ensure that the connection part is placed at the bending
part on the protective tube.
(4) Following to works of 1 of
parts as original in the reverse procedure.
Procedure
and (1) to (9), detach
and (1) to (9), attach the
– 173 –
Remarks
Relay lead wire
connector
for PMV coil
Binding band
Relay lead wire
Tube
for PMV coil
PMV coil
Remove the PMV coil while holding
the PMV body so that the pipe does
not deform.
<Installing PMV coil>
Attach the PMV coil to the PMV body so
that the PMV coil protrusion part points to
the PMV body inlet.
Fit the claw holes
on the PMV coil into
four claws on the
PMV body.
PMV body inlet
Direction of the PMV
coil protrusion part.
Ensure that the lock
part on the binding
Binding band
band comes to the
position in the figure.
PMV coil
lead wire
PMV body
PMV coil